• Title/Summary/Keyword: three gates

Search Result 128, Processing Time 0.031 seconds

Development of a Runner and Gate Design System for Injection Mold Design based on Unigraphics (사출 금형에서의 솔리드 모델러 기반 런너 및 게이트 설계 시스템 개발)

  • 이상헌;김창준;조병철;이강수;양진석;허영무
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.716-719
    • /
    • 1997
  • This paper describes the runner and gate design capabilities of the RAMEDS system, which is a specialized CAD system for injection mold design, dcvcloped using the application procedure interface of the Unigraphics system. In this system, runners lying on sculptuted partlng surface can be modeled by projecting the runner trajectory on the surface and sweeping a selected cross section along the projcctcd trajectory. In addtion, the system provides solid modeling capabilities for three types of gates currently.

  • PDF

Optimization of the Thin-walled Aluminum Die Casting Die Design by Solidification Simulation (응고 시뮬레이션에 의한 박육 알루미늄 다이캐스팅 금형 방안의 최적화)

  • Kim, Young-Chan;Cho, Se-Weon;Cho, Jae-Ik;Jeong, Chang-Yeol;Kang, Chang-Seog
    • Journal of Korea Foundry Society
    • /
    • v.28 no.4
    • /
    • pp.190-194
    • /
    • 2008
  • Thin-walled die casting of aluminum notebook computer housing with less than 1mm thickness was investigated by using computational solidification simulation and actual casting experiment. Three different types of gate design, finger, tangential and split type, were used and the results showed that sound thin-walled die casting was possible with tangential and split type gating design because those gates allowed aluminum melt flowed into the thin-wall cavity uniformly and split type gating system was preferable gating design than tangential type at the point of view of soundness of casting and distortion generated after solidification. Also, solidification simulation agreed well with the actual die-casting and the casting showed no casting defect and distortion.

Development of Engineering Plastic Gear Based on Injection Molding Process (사출성형공정에 의한 엔지니어링 플라스틱 기어 개발)

  • Min, Byeong-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.71-78
    • /
    • 1999
  • The application range of injection molded parts is expanding by the development of engineering plastics with good mechanical properties. Plastic gears are specially used as automotive parts due to an excellent performance in the characteristics of a strength vs. weight, and the study of injection molding process of plastic gear using Nylon66 is performed in this study. Filling, packing and cooling analyses were done by using the simulation software like Moldflow, and a mold was designed by following the simulation results. Pin-point gates with three points were taken to satisfy the design guides like a full-shot, and lower clamping force and uniform shrinkage. Characteristics of shrinkage of molded gear and temperature difference between cavity and core sides of a mold were shown.

  • PDF

The Effects of Types of Knowledge on the Performance of Fault Diagnosis (진단 수행도에 대한 지식형태의 효용에 관한 연구)

  • Ham, Dong-Han;Yoon, Wan-Chul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.22 no.3
    • /
    • pp.399-412
    • /
    • 1996
  • With respect to the effects of types of knowledge on human diagnostic performance, the results of several experiments claimed that training with procedural knowledge is more effective than training with principle knowledge. However, more useful results would be attained by investigating when and how the principles of system dynamics is valuable for diagnosis. Accordingly, we conducted an experiment to reevaluate the value of principle knowledge in two problem situations. A simulator system, named DLD, to diagnose an electronic device was created. It is a context-free digital logic circuit which includes forty-one gates of three basic types. The experiment investigated the effects of principle knowledge over common procedural knowledge. The experimental results showed that the effects of principle knowledge is dependent on the complexity of diagnostic situations. This adds up on experimental evidence against the presumed ineffectiveness of principle knowledge and forward reasoning in fault diagnosis. The results also suggest the source of the usefulness of principle knowledge.

  • PDF

Ultradense 2-to-4 decoder in quantum-dot cellular automata technology based on MV32 gate

  • Abbasizadeh, Akram;Mosleh, Mohammad
    • ETRI Journal
    • /
    • v.42 no.6
    • /
    • pp.912-921
    • /
    • 2020
  • Quantum-dot cellular automata (QCA) is an alternative complementary metal-oxide-semiconductor (CMOS) technology that is used to implement high-speed logical circuits at the atomic or molecular scale. In this study, an optimal 2-to-4 decoder in QCA is presented. The proposed QCA decoder is designed using a new formulation based on the MV32 gate. Notably, the MV32 gate has three inputs and two outputs, which is equivalent two 3-input majority gates, and operates based on cellular interactions. A multilayer design is suggested for the proposed decoder. Subsequently, a new and efficient 3-to-8 QCA decoder architecture is presented using the proposed 2-to-4 QCA decoder. The simulation results of the QCADesigner 2.0.3 software show that the proposed decoders perform well. Comparisons show that the proposed 2-to-4 QCA decoder is superior to the previously proposed ones in terms of cell count, occupied area, and delay.

A Stud on the Space Organization and Composition Elements in Gangwon Gamyoung (강원감영의 공간구성과 구성요소의 건축적 특징에 관한 연구)

  • Choi, Jang-Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.7 no.2
    • /
    • pp.31-47
    • /
    • 2005
  • This study is to inspect and analyse the historical background, spacial organization and architectural features about the traditional government office building of Gangwon Gamyoung(the supreme local government office of Gangwondo in Chosun dynasty). The results are as follows. - Gangwon Gamyoung was located at the center of Gangwondo in consideration of distance to each small local office. And also it was located in consideration of geographical connection between Hanseong(today's Seoul). - The spatial organization of Gamyoung was divided into the three parts of entrance space, government office building space and backyard space. The entrance space was composed of three gates(Pojungru-Jungsammun-Naesammun). The government office building Space was consisted of business and living building as center of Sunhwadang(the main office building). And the backyard space was composed of Yonji(pond), Jungja(bower), and so on - The way to enter the space of Gamyoung follows the order from Pojungru(the first & outer main gate with a bower), Jungsammun(the second & intermediate gate), Naesammun(the third & inner gate) to Sunhwadang at last. - There were a beautiful Yonji(pond) which to be rectangular type and to have a round island with Bongraegak(bower) at Gamyoung backyard, the drain conduit and pedestrian road covered with pebble in the ground.

  • PDF

Managing maritime automobile terminals: an approach toward decision-support model for higher productivity

  • Beskovnik, Bojan;Twrdy, Elen
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.4
    • /
    • pp.233-241
    • /
    • 2011
  • The article describes actions and strategies to obtain higher productivity on maritime automobile terminals. The main focus is on elaboration of efficient and effective organizational structure to model and implement short-term, mid-term and long-term strategies. In addition, with an empiric approach we combined the analyses of current findings in important scientific papers and our acknowledgments in practical research of north Adriatic maritime automobile terminals. The main goal is to propose actions towards increasing system's productivity. Based on our research of the north Adriatic maritime automobile terminals and with Lambert's model an in-deep analysis of limiting factors, user's expectations and possibilities for productivity increase has been performed. Moreover, with our acknowledgments a three-level decision-support model is presented. With an adequate model implementation it is possible to efficiently develop and implement different strategies of productivity measurement and productivity increase, especially in the fields of internal transport productivity, entrance/exit truck gates operations and wagon manipulations. According to our observation a significant increase might be achieved in all three fields.

A Basic Study on Implementing Optimal Function of Motion Sensor for Bridge Navigational Watch Alarm System

  • Jeong, Tae-Gweon;Bae, Dong-Hyuk
    • Journal of Navigation and Port Research
    • /
    • v.38 no.6
    • /
    • pp.645-653
    • /
    • 2014
  • A Bridge Navigational Watch Alarm System (hereafter 'BNWAS') is to monitor and detect if an officer of watch(hereafter 'OOW') keeps a sharp lookout on the bridge. The careless lookout of an OOW could lead to marine accidents. For this reason on June 5th, 2009, IMO decided that a ship is equipped with a BNWAS. However, an existing BNWAS gives the OOW a lot of inconvenience and stress in its operation. It requires that the OOW should press reset buttons to confirm their alert watch on the bridge at every three to twelve minute. Many OOWs have complained that at some circumstances they cannot focus on their bridge activities including watch-keeping due to a lots of resetting inputs of BNWAS. Accordingly, IMO has allowed the use of a motion sensor as a resetting device. The motion sensor detects the movements of human body on the bridge and subsequently sends reset signals directly to BNWAS automatically. As a result, OOWs can work uninterrupted. However, some of classification societies and flag authorities have a slightly different stance on the use of motion sensor as a resetting method for BNWAS. The reason is that the motion sensor may trigger false reset signals caused by the motion of objects on the bridge, especially a slight movement such as toss and turn of human body which can extend the period of careless watch. As a basic study to minimize the false reset signals, this paper proposes a simple configuration of BNWAS, which consists of only three motion sensors associated with 'AND' and 'OR' logic gates. Additionally, several considerations are also proposed for the implementation of motion sensors. This study found that the proposed configuration which consists of three motion sensors is better than an existing one by reducing false reset signals caused by a slight movement of human body in one's sleep. The proposed configuration in this paper filters false reset signals and is simple to be implemented on existing vessels. In addition, it can be easily installed just by a basic electrical knowledge.

Optimization of GFR value according to Kidney Depth Measurement Methods (신장 Depth 측정 방법에 따른 GFR 값의 최적화)

  • Kwon, Hyeong-Jin;Moon, Il-Sang;Noh, Gyeong Woon;Kang, Keon Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Purpose In patients with unusual kidney position after $^{99m}Tc-DTPA$ renal dynamic imaging study, the GFR(Glomerular Filtration Rate) values are significantly different according to the depth of the kidney. Thus, we tried to compare the difference of the GFR values between the depth measurement methods and in-vitro test. 30 adult patients who were subjected to renal study. 27 patients were in usual position and 3 patients were in unusual. $555{\pm}37MBq$ of $^{99m}Tc-DTPA$ was administrated to all patients. GE infinia gamma camera was used. GFR values were obtained in-vivo(gates method) and in-vitro(blood). The kidney depth in-vivo was calculated by three methods(tonnensen, manual, taylor). In-vitro, GFR was performed by blood test. Differences in the mean values of GFR and correlation between depth and GFR values were evaluated using the SPSS 12.0 statistical program. The GFR values for 27 patients with kidney in the usual position are as follows(1.tonnensen 2.manual 3.taylor 4.invitro); $69.3{\pm}4.2$, $88.2{\pm}5.6$, $77.8{\pm}4.3$, $82.2{\pm}5.8ml/min$. The three unusual cases are as follows, first(congenital renal anomaly): 66.4, 101.24, 69.07, 94.8 ml/min. second(transplantation kidney): 12.22, 29.99, 19.36, 23.5 ml/min. third(horseshoe kidney): 37.37, 93.54, 35.9, 92.5 ml/min. There was a difference between tonnensen and manual in the usual position of the kidney(p<0.05). There was no significant difference between the other methods. However, there was a significant difference in case of the unusual position of the kidneys. Correlation analysis between both kidney depth and GFR value shows person correlation as follows; Rt kidney: 0.298, Lt kidney: 0.322. When compared with the GFR values in-vitro test, it was useful to calculate the GFR value by measuring the kidney depth using a manual formula in the unusual position of the kidneys. GFR values and kidney depth were significantly related.

Expression of Low Voltage-Activated $Ca^{2+}$ Channels in Xenopus Oocytes

  • Lee, Jung-Ha;Han, Dong-Pyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.614-618
    • /
    • 2001
  • Low-threshold T-type $Ca^{2+}$ channels are distinctive voltage-operated gates for external $Ca^{2+}$ entry around a resting membrane potential due to their low voltage activation. These phenomena have already been extensively studied due to their relevance in diverse physiological functions. Recently, three T-type $Ca^{2+}$ channel ${\alpha}$$_1$subunits were cloned and their biophysical properties were characterized after expression in mammalian expression systems. In this study, ${\alpha_IG} and {\alpha_IH}$ low-threshold $Ca^{2+}$ channels were expressed and characterized in Xenopus oocytes after adding 5' and 3'untranslated portions of a Xenopus ${\beta}$ globin to improve their expression levels. The added portions dramatically enhanced the expression levels of the ${\alpha_IG} and {\alpha_IH}$ T-type channels. When currents were recorded in 10 mM $Ba^{2+}$ as the charge carrier, the activation thresholds were about -60 mV, peak currents appeared at -20 mV, and the reversal potentials were between +40 and +45. The activation time constants were very similar to each other, while the inactivation time constants of the ${\alpha_IG}$ currents were smaller than those of ${\alpha_IH}$. Taken together, the electrophysiological properties of the ${\alpha_IG} and {\alpha_IH}$ channels expressed in Xenopus oocytes were similar to the previously reported characteristics of low-threshold $Ca^{2+}$ channel currents.

  • PDF