• Title/Summary/Keyword: three dimensional measurement

Search Result 1,026, Processing Time 0.027 seconds

Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions (ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석)

  • Kim, Jongmin;Kim, Seojun;Son, Geunsoo;Kim, Dongsu
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.553-566
    • /
    • 2015
  • Acoustic Doppler Current Profilers(ADCPs) have capability to concurrently capitalize three-dimensional velocity vector and bathymetry with highly efficient and rapid manner, and thereby enabling ADCPs to document the hydrodynamic and morphologic data in very high spatial and temporal resolution better than other contemporary instruments. However, ADCPs are also limited in terms of the inevitable unmeasured regions near bottom, surface, and edges of a given cross-section. The velocity in those unmeasured regions are usually extrapolated or assumed for calculating flow discharge, which definitely affects the accuracy in the discharge assessment. This study aimed at scrutinizing a conventional extrapolation method(i.e., the 1/6 power law) for estimating the unmeasured regions to figure out the accuracy in ADCP discharge measurements. For the comparative analysis, we collected spatially dense velocity data using ADV as well as stationary ADCP in a real-scale straight river channel, and applied the 1/6 power law for testing its applicability in conjunction with the logarithmic law which is another representative velocity law. As results, the logarithmic law fitted better with actual velocity measurement than the 1/6 power law. In particular, the 1/6 power law showed a tendency to underestimate the velocity in the near surface region and overestimate in the near bottom region. This finding indicated that the 1/6 power law could be unsatisfactory to follow actual flow regime, thus that resulted discharge estimates in both unmeasured top and bottom region can give rise to discharge bias. Therefore, the logarithmic law should be considered as an alternative especially for the stationary ADCP discharge measurement. In addition, it was found that ADCP should be operated in at least more than 0.6 m of water depth in the left and right edges for better estimate edge discharges. In the future, similar comparative analysis might be required for the moving boat ADCP discharge measurement method, which has been more widely used in the field.

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

On the Study of Initializing Extended Depth of Focus Algorithm Parameters (Extended Depth of Focus 알고리듬 파라메타 초기설정에 관한 연구)

  • Yoo, Kyung-Moo;Joo, Hyo-Nam;Kim, Joon-Seek;Park, Duck-Chun;Choi, In-Ho
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.625-633
    • /
    • 2012
  • Extended Depth of Focus (EDF) algorithms for extracting three-dimensional (3D) information from a set of optical image slices are studied by many researches recently. Due to the limited depth of focus of the microscope, only a small portion of the image slices are in focus. Most of the EDF algorithms try to find the in-focus area to generate a single focused image and a 3D depth image. Inherent to most image processing algorithms, the EDF algorithms need parameters to be properly initialized to perform successfully. In this paper, we select three popular transform-based EDF algorithms which are each based on pyramid, wavelet transform, and complex wavelet transform, and study the performance of the algorithms according to the initialization of its parameters. The parameters we considered consist of the number of levels used in the transform, the selection of the lowest level image, the window size used in high frequency filter, the noise reduction method, etc. Through extended simulation, we find a good relationship between the initialization of the parameters and the properties of both the texture and 3D ground truth images. Typically, we find that a proper initialization of the parameters improve the algorithm performance 3dB ~ 19dB over a default initialization in recovering the 3D information.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

3D Modeling of Turbid Density Flow Induced into Daecheong Reservoir with ELCOM-CAEDYM (ELCOM-CAEDYM을 이용한 대청댐 유입탁수의 3차원 모델링)

  • Chung, Se-Woong;Lee, Heung-Soo;Ryoo, Jae-Il;Ryu, In-Gu;Oh, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1187-1198
    • /
    • 2008
  • Many reservoirs in Korea and their downstream environments are under increased pressure for water utilization and ecosystem management from longer discharge of turbid flood runoff compared to a natural river system. Turbidity($C_T$) is an indirect measurement of water 'cloudiness' and has been widely used as an important indicator of water quality and environmental "health". However, $C_T$ modeling studies have been rare due to lack of experimental data that are necessary for model validation. The objective of this study is to validate a coupled three-dimensional(3D) hydrodynamic and particle dynamics model (ELCOM-CAEDYM) for the simulation of turbid density flows in stratified Daecheong Reservoir using extensive field data. Three different groups of suspended solids (SS) classified by the particle size were used as model state variables, and their site-specific SS-$C_T$ relationships were used for the conversion between field measurements ($C_T$) and state variables (SS). The simulation results were validated by comparing vertical profiles of temperature and turbidity measured at monitoring stations of Haenam(R3) and Dam(R4) in 2004. The model showed good performance in reproducing the reservoir thermal structure and propagation of stream density flow, and the magnitude and distribution of turbidity in the reservoir were consistent with the field data. The 3D model and turbidity modeling framework suggested in this study can be used as a supportive tool for the best management of turbidity flow in other reservoirs that have similar turbidity problems.

Improvement of Skin Moisture Capacity through Dietary Beauty Supplement Containing Ceramides Derived from Rice (쌀 유래 세라마이드를 함유한 미용보조제의 피부미용개선 효과)

  • Kim, Tae-Su;Lee, Sung-Pyo;Park, So-I;Yang, Woong-Suk;Kang, Myung-Hwa;Murai, Hiromichi;Okada, Tadashi;Lee, Jae-Hwan;Park, Il-Bum;Park, Hyun-Jun
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.434-440
    • /
    • 2012
  • A placebo-controlled double-blind ingestion study of a beauty supplement containing rice-derived ceramide was performed. Thirty three subjects who always tended to have rough skin due to dryness participated in the study. Dermatological diagnosis by physicians showed that the supplement significantly improved dryness and itching of the skin. On measurement of water content in the skin, the supplement was shown to significantly increase water content in the skin. On microscopic three-dimensional analysis of the epidermis, the supplement was shown to improve smoothness, exfoliation, and short-term ingestion of the supplement containing rice derived ceramide, which is very effective as skin beautifying food.

A Study on the Strategic Orientation and the Performance of IT Startups : The Moderating Effect of Corporate Social Responsibility Orientation (IT스타트업의 전략적 지향성과 성과에 관한 연구 : 기업의 사회적 책임 지향성 조절효과)

  • Shim, Yunsoo;Seo, Jounghae;Park, Eunmi
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.1
    • /
    • pp.127-138
    • /
    • 2021
  • The aim of this study is to investigate the effects of each of the three sub-dimensional strategic orientations of technology orientation, customer orientation, and competitor orientation, on performance, targeting IT startups based on technology. and to analyze moderating effect of corporate social responsibility, which is more important to modern society. For the analysis, , The IT startups completed empirical research through path analysis after evaluating the suitability of measurement models and structural models using PLS-SEM for 94 companies less than 7 years that have moved in startup support institutions. As a result of the study, the three sub-dimensions of strategic orientation, technology orientation, customer orientation, and competitor orientation, all had a positive (+) effect on startups' performance. and the Corporate social responsibility orientation was verified as moderating the startup's strategic orientation and startups' performance. The results of this study imply the importance of corporate social responsibility orientation in the strategy setting of start-ups, as well as the direction of strategy-setting for technology-based startups for competitive advantage and long-term survival.

Experimental Investigation of Aerodynamic Force Coefficients and Flutter Derivatives of Bridge Girder Sections (교량단면의 공기력계수 및 플러터계수에 관한 실험적 연구)

  • Cho, Jae-Young;Lee, Hak-Eun;Kim, Young-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.887-899
    • /
    • 2006
  • The aim of this study is to investigate a correlation between fundamental data on aerodynamic characteristics of bridge girder cross-sections, such as aerodynamic force coefficients and flutter derivatives, and their aerodynamic behaviour. The section model tests were carried out in three stages. In the first stage, seven deck configurations were studied, namely; Six 2-edge girders and one box girder. In this stage, changes in aerodynamic force coefficients due to geometrical shape of girders, incidence angle of flow, wind directions and turbulence intensities were studied by static section model tests. In the second stage, the dynamic section model tests were carried out to investigate the relativity of static coefficients to dynamic responses. And finally, the two-dimensional (lift-torsion) aerodynamic derivatives of three bridge deck configurations were investigated by dynamic section model tests. The aerodynamic derivatives can be best described as a representation of the aerodynamic damping and the aerodynamic stiffness provided by the wind for a given deck geometry. The method employed here to extract these unsteady aerodynamic properties is known as the initial displacement technique. It involves the measurement of the decay in amplitude with time of an initial displacement of the deck in heave and torsion, for various wind speeds, in smooth flow. It is suggested that the proposed aerodynamic force coefficients and flutter derivatives of bridge girder sections will be potentially useful for the aeroelastic analysis and buffeting analysis.

2D Backtracking Method of Ultrasonic Signal (초음파 신호의 2차원 역추적 방법에 관한 연구)

  • Kyu-Joung Lee;Choong Ho Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.172-177
    • /
    • 2023
  • In this paper, 2-dimensional backtracking method for ultrasonic signals. Ultrasonic sensors are a common technology used in industrial fields as many studies have been conducted on distance measurement and indoor location tracking using transmission and reception devices in pairs. A method for tracking a signal of an arbitrary ultrasonic transmission device on a 2D plane using only a receiver of an ultrasonic signal is proposed. In order to track the ultrasonic signal, the receiver receives the signal by making at least three. The three receivers may calculate a direction and a distance using a time difference in which the ultrasound reception sound is reached. The existing method of tracking signal sources using ultrasonic waves has a problem of time synchronization of devices because the transceivers must be paired or installed independently for each sensor. In order to solve this problem, the distance of the ultrasonic receiver is minimized, and it is configured as one device. The sensor installed as one device may be processed by one operator, thereby solving the time synchronization problem. To increase time difference accuracy, high-speed 32-bit timers with high time resolution can be used to quickly calculate and track distances and directions.