• Title/Summary/Keyword: three different solutions

Search Result 519, Processing Time 0.032 seconds

Effects of Seed Size and Several Factors on Ultra-drying and Germination of Ultra-dried Seeds in Soybean

  • Lee, Yeong-Ho;Chang, Ching-huan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.45 no.5
    • /
    • pp.305-309
    • /
    • 2000
  • Ultra-drying [<5.0% seed moisture content (SMC)] storage technique is a cost-effective storage method for oily seeds. To decide proper ultra-drying condition for soybean seeds, drying rate was compared three silica gel to seed ratios, two seed sizes with varietal difference, two kinds of container, and three seed amounts per container under :t 23$\pm$1$^{\circ}C$. When the relative humidity (RH) was reduced at the rate of less than 0.1 % a day, silica gel was replaced with dry one by 47 days. Higher silica gel to seed ratios (3:1 and 2:1) dried faster than lower ratio (1:1) until 28 days, but not after 43 days of drying. Also, large seeded variety was dried faster than small seeded variety. Kinds of container and seed amounts per container didn't show differences in drying of soybean seeds. After completion of ultra-drying, percentage germination by standard germination test (SGT) was not different among silica gel to seed ratios, kinds of container, and seed amounts per container, except among seed sizes (varieties). Before SGT, soybean seeds were premoistened using saturated ${CaCl}_2$ for 48 hours and ${NH}_4$Cl for 24 hours in desiccators. To compare germinability between ordinary-dried seeds and ultra-dried seeds, the seeds of seven soybean varieties, which were varying in size from 8.1 to 34.9 g per 100 seeds, were dried using same amount of silica gel under 23$\pm$1$^{\circ}C$. After completion of 76 days of drying, SMCs were reduced to 3.13-3.45% from 7.86-8.82%. SMC after completion of drying was not correlated with 100-seed weight (r=0.556). Before germination tests, soybean seeds were premoistened using saturated salt solutions. Percentage germination was higher with ultra-dried seeds than ordinary-dried seeds in SGT and higher with ordinary-dried seeds than ultra-dried seeds in AAT at the beginning of storage and after 6 months storage, but general trend of percentage germination was not observed among varieties classified by 100-seed weight. From these results, we concluded that further studies are needed to improve ultra-drying storage method for soybean seeds.

  • PDF

Development of a Frequency Dependent Type Apex Locator with Automatic Compensation (자동 보정 주파수 의존형 근관장 측정기의 개발)

  • Kim, Deok-Won;Nam, Gi-Chang;Kim, Yeong-Ju;Lee, Seung-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.595-602
    • /
    • 1998
  • Among the apex locators, the frequency dependent type is more accurate and convenient to use than others, But the accuracy of the apex locator is still influenced by the presence of various electrolytes used in root canal treatments. In this study, we have developed a frequency dependent electronic apex locator minimizing the influence of the electrolytes on the measurement of root canal lengths. It was also confirmed that two frequencies of 500Hz and 100kHz are optimal for the measuring impedance compare with commercial product used(400Hz and 8kHz)a and there were no differences in accuracy among the three different types of the waveforms; sinusoidal, triangular, and rectangular waves(p>0.05). Impedance ratio of the two different frequencies represents the position of the file in root canal, and the voltage difference of two signals represents the status of the fluid in the root canal. As a result of compensation using the voltage differences, the errors were decreased on the average from +0.54mm to +0.18mm in $H_2O_2$ solution (p<0.01), and from -0.33mm to -0.01mm in NaOCl solution(p<0.01). The accuracies based on ${\pm}$0.5mm, in $H_2O_2$ and NaOCl solutions were improved with the automatic compensation from 71.1% and 91.1% to 82.2% and 100% respectively.

  • PDF

Studies on Heavy Metal Ion Adsorption by Soils. -(Part 1) PH and phosphate effects on the adsorption of Cd, Cu, Ni and Zn by mineral soils with low CEC and low organic carbon content (중금속(重金屬) 이온의 토양(土壤) 흡착에 관한 연구 -(제1보) CEC 및 유기탄소 함량이 낮은 광물토양에의 Cd, Cu, Ni, 및 Zn의 흡착과 이에 미치는 pH 및 인산의 효과-)

  • Kim, Myung-Jong;Motto, Harry L.
    • Applied Biological Chemistry
    • /
    • v.20 no.3
    • /
    • pp.300-309
    • /
    • 1977
  • The information related to the heavy metal pollution in the environment was obtained from studies on the effects of pH, phosphate and soil properties on the adsorption of metal ions (Cd, Cu, Ni, and Zn) by soils. Three soil materials; soil 1 with low CEC (8.2 me/100g) and low organic carbon content (0.34%); soil 2 with high CEC (36.4 me/100g) and low organic carbon content (1.8%) and soil 3 with high CEC (49.9 me/100g) and high organic carbon content (14.7%) were used. Soils were adjusted to several pH's and equilibrated with metal ion mixtures of 4 different concentrations, each having equal equivalents of each metal ion (0.63, 1.88, 3.12 and 4.38 micromoles per one gram soil with and without 10 micromoles of phosphate per one gram soil). Reported here are the results of the equilibrium study on soil I. The rest of the results on soil 2 and soil 3 will be repoted subsequeutly. Generally higher metal ion concentration solution resulted in higher final metal ion concentrations in the equilibrated solution and phosphate had minimal effect except it tended to enhance removal of cadmium and zinc from equilibrated solutions while it tended to decrease the removal of copper and nickel. In soil 1, percentages of added metal ions removed at pH 5.10 were; Cu 97, Ni 69, Cd 63, and Zn 55, while increasing pH to 6.40, they were increased to Cu 90.9, Zn 99, Ni 96, and Cd 92 per As initial metal ion concentration increased, final metal ion concentrations in the equilibrated solution showed a relationship with pH of the system as they fit to the equation $p[M^{++}]=a$ pH+b where $p[M^{++}]=-log$[metal ion concentration in Mol/liter]. The magnitude of pH and soil effects were reflected in slope (a) of the equation, and were different among metal ions and soils. Slopes (a) for metal ions in the aqueous system are all 2. In soil 1 they were; Zn 1.23, Cu 0.99, Ni 0.69 and Cd 0.59 at highest concentration. The adsorption of Cd, Ni, and Zn in soil 1 could be represented by the Iangmuir isotherm. However, construction of the Iangmuir isotherm required the correction for pH differences.

  • PDF

GA-Based Optimal Design for Vibration Control of Adjacent Structures with Linear Viscous Damping System (선형 점성 감쇠기가 장착된 인접구조물의 진동제어를 위한 유전자 알고리즘 기반 최적설계)

  • Ok, Seung-Yong;Kim, Dong-Seok;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.11-19
    • /
    • 2007
  • This paper proposes an optimal design method of distribution and capacities of linear viscous dampers for vibration control of two adjacent buildings. The previous researches have dealt with suboptimal design problem under the assumption that linear viscous dampers are distributed uniformly or proportionally to the sensitivity of the modal damping ratio according to floors, whereas this study deals with global optimization problem in which the damping capacities of each floor are independently selected as design parameters. For this purpose, genetic algorithm to effectively search multiple design variables in large searching domains is adopted and objective function leading to the global optimal solutions is established through the comparison of several optimal design values obtained from different objective functions with control performance and damping capacity. The effectiveness of the proposed method is investigated by comparing the control performance and total damping capacity designed by the proposed method with those of the previous method. In addition, the time history analyses are performed by using three historical earthquakes with different frequency contents, and the simulation results demonstrate that the proposed method is an effective seismic design method for the vibration control of the adjacent structures.

Frictional resistance of different ceramic brackets and their relationship to the second order angulation between bracket slot and wire (세라믹 브라켓의 종류 및 브라켓 슬롯과 와이어 각도에 따른 마찰 저항 차이)

  • Choi, Yoon-Jeong;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.207-217
    • /
    • 2006
  • Although ceramic brackets have been used widely for improved esthetics during treatment, ceramic brackets have some inherent problems; brittleness, attrition of the opposing teeth and high frictional resistance. This study was performed to understand the frictional resistance of the ceramic brackets, as well as to be a helpful reference for finding the solutions to the problem of frictional resistance. Three different kinds of brackets were used; metal bracket, polycrystalline ceramic brackets with a metal slot to reduce the high frictional resistance and monocrystalline ceramic brackets. The brackets were tested with a $.019{\times}.025$ stainless steel wire with a second order angulation of $0^{\circ}\;and\;10^{\circ}$, and the static and kinetic frictional forces were measured on the universal testing machine. The results of this study showed that the ceramic brackets, especially the monocrystalline ceramic bracket without a metal slot, generated higher frictional resistance than the metal bracket, and the frictional resistance was increased as the angulation between the bracket slot and the wire increased. Therefore, the development of the ceramic bracket with reduced frictional resistance and the prevention of excessive crown tipping during orthodontic treatment will lead to the simultaneous attainment of more efficient and improved esthetic treatment goals.

A Proposition on Landscape Restoration of Joseon Dynasty's Palace Gardens (조선시대 궁궐정원의 원형경관 복원을 위한 제안)

  • Ahn, Gye-Bog;Lee, Won-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.10-20
    • /
    • 2014
  • The purpose of this study is to define criteria for landscape restoration of palace gardens. The case study on Gyeongbokgung and Changdeokgung was used not only to evaluate effectiveness of the criteria, but also to propose solutions to issues of current restoration process of both palace gardens. Following three pairs of different concepts were chosen as criteria to determine on the original form: Diachrony vs. Synchrony, Originality vs. Contemporary Characteristics, and Invariance vs. Deformability. Gyeongbokgung has been restored based on its contemporary characteristics of Year 1888 and the main focus is on its architectural features rather than both architecture and landscape. However, in-depth complementary work on landscape restoration is necessary to restore its originality in Year 1395 such as analyzing photos of Gyeongbokgung taken in modern era. In case of Changdeokgung, we analyzed separately by region or landmark such as Jondeok-Pavilion(尊德亭), Yeonkyung-Hall(演慶堂), and Okryu-Stream(玉流川). Original form of Jondeok-Pavilion Area was changed in 1884. Since diachronic invariance that lasted for 240 years is more important criterion than its contemporary characteristics, it should be restored as how it was painted in Donggwoldo(東闕圖). In Yeonkyung-Hall Area, both original characteristics at the time of Hyomyung Crown Prince and contemporary characteristics of Emperor Kojong Era appear. Therefore, different solution is required for such area to be restored appropriately. Starting from era of King Injo(1636), diachrony and invariance of Okryu-Stream Area were continued throughout the era of King Sukjong and King Jeongjo(1800). It is more than 250 years before Okryu-Stream Area was altered under the rule of Emperor Kojong in 1884. In fact, alterations made to Okryu-Stream Area after 1884 doesn't hold much significance. Therefore, water landscape of Okryu-Stream Area, which was altered in the era of Emperor Kojong, needs to be restored based on Donggwoldo.

THE DYNAMIC CHANGE OF ARTIFICIALLY DEMINERALIZED ENAMEL BY DEGREE OF SATURATION OF REMINERALIZATION SOLUTION AT pH 4.3 (pH 4.3에서 재광화 용액의 포화도에 따른 인공 탈회된 법랑질의 동력학적 변화)

  • Yi, Ji-Sook;Roh, Bung-Duk;Shin, Su-Jung;Lee, Yoon;Gong, Hyung-Kyu;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.20-29
    • /
    • 2009
  • The purpose of this study is to observe and compare the dynamic change of artificially demineralized enamel by remineralization solutions of different degrees of saturation at pH 4.3. In this study, 30 enamel specimens were demineralized artificially by lactic acid buffered solution. Each of 10 specimens was immersed in pH 4.3 remineralization solution of three different degrees of saturation (0.22, 0.30, 0.35) for 10 days. After demineralization and remineralization, images were taken by a polarizing microscope (${\times}100$). The density of lesion were determined from images taken after demineralization and remineralization. During remineralization process, mineral deposition and mineral loss occurred at the same time. After remineralization, total mineral amount and width of surface lesion increased in all groups. The higher degree of saturation was, the more mineral deposition occurred in surface lesion and the amount of mineral deposition was not much in subsurface lesion. Total demineralized depth increased in all groups.

A Mathematical Model for Strategic Decision Making in Two Level Supply Chain Network Design (2단계 공급사슬 네트워크에서 전략적 의사결정을 위한 수리적 모형)

  • Chung, Ki-Ho
    • Management & Information Systems Review
    • /
    • v.32 no.3
    • /
    • pp.107-125
    • /
    • 2013
  • This study deals with a strategic decision making in two level supply chain network design. This study presents more realistic mathematical model than the previous studies by considering simultaneous location of plants and distribution centers, determination of capacity level for both plants and distribution centers, and upper limit condition for numbers of locating plants and distribution centers. This paper tries to help the strategic decision making for two level supply chain network design. For this purpose, three different sized numerical examples are generated and optimal solutions are obtained by applying Excel Solver program. And sensitivity analysis is performed for the biggest sized example problem, which has 10 potential plants, 20 potential distribution centers, and 200 customer zones. After the plants being located are fixed, optimal minimum costs are obtained and compared for each of 7 different numbers of distribution centers to be located. As the number of distribution centers increases, changes in inbound transportation cost and outbound transportation cost can be derived. In case of considering cost as well as customer satisfaction level for two level supply chain network design, the analysis of this changes may help more sophisticated decision making.

  • PDF

The improvement of electrical properties of InGaZnO (IGZO)4(IGZO) TFT by treating post-annealing process in different temperatures.

  • Kim, Soon-Jae;Lee, Hoo-Jeong;Yoo, Hee-Jun;Park, Gum-Hee;Kim, Tae-Wook;Roh, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.169-169
    • /
    • 2010
  • As display industry requires various applications for future display technology, which can guarantees high level of flexibility and transparency on display panel, oxide semiconductor materials are regarded as one of the best candidates. $InGaZnO_4$(IGZO) has gathered much attention as a post-transition metal oxide used in active layer in thin-film transistor. Due to its high mobility fabricated at low temperature fabrication process, which is proper for application to display backplanes and use in flexible and/or transparent electronics. Electrical performance of amorphous oxide semiconductors depends on the resistance of the interface between source/drain metal contact and active layer. It is also affected by sheet resistance on IGZO thin film. Controlling contact/sheet resistance has been a hot issue for improving electrical properties of AOS(Amorphous oxide semiconductor). To overcome this problem, post-annealing has been introduced. In other words, through post-annealing process, saturation mobility, on/off ratio, drain current of the device all increase. In this research, we studied on the relation between device's resistance and post-annealing temperature. So far as many post-annealing effects have been reported, this research especially analyzed the change of electrical properties by increasing post-annealing temperature. We fabricated 6 main samples. After a-IGZO deposition, Samples were post-annealed in 5 different temperatures; as-deposited, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$ and $500^{\circ}C$. Metal deposition was done on these samples by using Mo through E-beam evaporation. For analysis, three analysis methods were used; IV-characteristics by probe station, surface roughness by AFM, metal oxidation by FE-SEM. Experimental results say that contact resistance increased because of the metal oxidation on metal contact and rough surface of a-IGZO layer. we can suggest some of the possible solutions to overcome resistance effect for the improvement of TFT electrical performances.

  • PDF

Analysis of Solute Transport based on Electrical Resistance Measurements from Laboratory Column Tests (전기저항센서가 부착된 주상실험기에서 측정된 전기저항값을 이용한 용질의 이동해석)

  • Kim, Yong-Sung;Kim, Jae-Jin;Park, Junboum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.231-238
    • /
    • 2008
  • A column testing device capable of measuring the electrical resistivity of soil at 3 different locations was developed to verify applicability of bulk electrical conductivity (BEC) breakthrough curves in monitoring contaminant transport. Tracer injection tests were conducted with three different types of saturated sands to obtain average linear velocities and longitudinal hydrodynamic dispersion coefficients based on BEC breakthrough curves and effluent solute breakthrough curves. Comparative analysis of transport parameters obtained from curve fitting the results into the analytical solutions confirmed the validity of resistance measurements in estimating time-continuous resident solute concentration. Under the assumption that a linear relationship exists between ${\sigma}_{sat}-{\sigma}_w-C$, the BEC breakthrough curves are able to effectively reduce the laborious and time-consuming processes involved in the conventional method of sampling and analysis. In order to reduce possible uncertainties in analyzing the BEC breakthrough curves, it was recommended that resistance measurements take place nearby the effluent boundary. In addition, a sufficient electrical contrast or difference in the electrical conductivity of the influent and the saturating solution is required to conduct reliable analysis.