• 제목/요약/키워드: thickness loss

검색결과 1,283건 처리시간 0.034초

기판의 유전율 및 전기적 두께가 X-벤드용 마이크로스트립 패치 안테나의 특성에 미치는 영향에 관한 연구 (A study of characteristics of X-band microstrip patch antenna affected b permittivity and electrical thickness of the substrate)

  • 박성교;김준현;박종배
    • 전자공학회논문지A
    • /
    • 제33A권3호
    • /
    • pp.65-81
    • /
    • 1996
  • In this study forty-five X-bnd rectangular microstrip patch antennas fed by microstrip line using ${\lambda}$/4 transformer were fabricated on teflon substrates with low high permittivities and varous thickness (substrate thickness : 0.6 ~ 2.4 mm, permittivities : 2.15 ~ 10.0), and effects of permittivity and electrical thickness on antenna characteristics were studied with measured return loss (1/S$_{11}$) and resonant frequencies. When substrate electrical thickness was greater than 0.060 ${\lambda}_{0}$return loss was very good and genrally more than 20 dB, but resonance characteristics was somewhat unstable. The more than 0.088 ${\lambda}_{0}$ the thickness was, the more unstable it was. As a result, in the rest range except 12, 13 GHz we had very good mesured return loss iwth greater than 20 dB, and in the range 7 to 9 GHz resonant frequencies were within $\pm$2 % error, on ${\epsilon}_{r}$=5.0, height = 2.4 mm substrate.

  • PDF

치관 전장용 레진의 내마모성에 대한 비교연구 (A COMPARATIVE STUDY ON THE WEAR RESISTANCE OF POLYMERIC VENEERING MATERIALS)

  • 윤수선;이선형;양재호;장완식
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.33-43
    • /
    • 1986
  • The purpose of this study was to compare the wear resistance of heat pressure-cured microcomposite(SR-Isosit-N), photo-cured microcomposite(Dentalcolor), unfilled heat-cured resin(Thermojel) and that of human enmel. Specimens were made with specially designed die and finally polished with #3,000 diamond paste. After 100,000 strokes of tooth brushing at electric tooth-brushing machine, mean thickness loss of each specimen was measured by using surface profile and integration. The results were as follows 1. Mean thickness loss were $84.3{\pm}27.3{\mu}m$ in unfiled heat-cured resin, $9.4{\pm}2.5{\mu}m$ in photocured microcomposite, $7.6{\pm}2.1{\mu}m$ in heat.pressure-cured microcomposite and $0.97{\pm}0.42{\mu}m$ in enamel. 2. Heat.pressure-cured microcomposite and photo-cured microcomposite had no difference in mean thickness loss(p>0.05). 3. Unfilled resin and microcomposite had much differences in mean thickness loss (p<0.005). 4. ha resins used in this experiment had too much mean thickness loss as compared with enamel (p<0.005).

  • PDF

고정된 바깥반경에 기준한 pin 핀의 최적화 (Optimization of a Pin Fin Based on Fixed Outer Radius)

  • 강형석;최수근
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.3-7
    • /
    • 2008
  • A cylindrical pin fin with variable fin base thickness is optimized based on fixed outer radius by using the one dimensional analytic method. Heat loss from the pin fin with fixed outer radius is presented as a function of the fin length. The ratio of in length for optimum heat loss to that for the maximum heat loss is listed. The maximum heat loss and effectiveness and the fin length for the optimum heat loss are presented as a function of fin base thickness and outer radius. One of the results presents the maximum effectiveness decreases rapidly first and then decreases slowly as the fin outer radius increases.

  • PDF

Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study

  • Yoo, Jaehyun;Moon, Ik-Sang;Yun, Jeong-Ho;Chung, Chooryung;Huh, Jong-Ki;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제49권3호
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: Implant wall thickness and the height of the implant-abutment interface are known as factors that affect the distribution of stress on the marginal bone around the implant. The goal of this study was to evaluate the long-term effects of supracrestal implant placement and implant wall thickness on maintenance of the marginal bone level. Methods: In this retrospective study, 101 patients with a single implant were divided into the following 4 groups according to the thickness of the implant wall and the initial implant placement level immediately after surgery: 0.75 mm wall thickness, epicrestal position; 0.95 mm wall thickness, epicrestal position; 0.75 mm wall thickness, supracrestal position; 0.95 mm wall thickness, supracrestal position. The marginal bone level change was assessed 1 day after implant placement, immediately after functional loading, and 1 to 5 years after prosthesis delivery. To compare the marginal bone level change, repeated-measures analysis of variance was used to evaluate the statistical significance of differences within groups and between groups over time. Pearson correlation coefficients were also calculated to analyze the correlation between implant placement level and bone loss. Results: Statistically significant differences in bone loss among the 4 groups (P<0.01) and within each group over time (P<0.01) were observed. There was no significant difference between the groups with a wall thickness of 0.75 mm and 0.95 mm. In a multiple comparison, the groups with a supracrestal placement level showed greater bone loss than the epicrestal placement groups. In addition, a significant correlation between implant placement level and marginal bone loss was observed. Conclusions: The degree of bone resorption was significantly higher for implants with a supracrestal placement compared to those with an epicrestal placement.

OPTIMZATION OF A PIN FIN BASED ON THE INCREASING RATE OF HEAT LOSS

  • Kang, Hyung-Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제12권1호
    • /
    • pp.25-32
    • /
    • 2008
  • A pin fin is optimized based on the increasing rate of heat loss by using a two-dimensional analytic method. The optimum heat loss, corresponding optimum thermal resistance and fin length are presented as a function of the fin base thickness, convection characteristic numbers ratio, fin outer radius and ambient convection characteristic number. One of the results shows that both the optimum heat loss and fin length decrease linearly whereas the optimum thermal resistance increases very slightly with increase of the fin base thickness.

  • PDF

에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

Influence of implant mucosal thickness on early bone loss: a systematic review with meta-analysis

  • Di Gianfilippo, Riccardo;Valente, Nicola Alberto;Toti, Paolo;Wang, Hom-Lay;Barone, Antonio
    • Journal of Periodontal and Implant Science
    • /
    • 제50권4호
    • /
    • pp.209-225
    • /
    • 2020
  • Purpose: Marginal bone loss (MBL) is an important clinical issue in implant therapy. One feature that has been cited as a contributing factor to this bone loss is peri-implant mucosal thickness. Therefore, in this report, we conducted a systematic review of the literature comparing bone remodeling around implants placed in areas with thick (≥2-mm) vs. thin (<2-mm) mucosa. Methods: A PICO question was defined. Manual and electronic searches were performed of the MEDLINE/PubMed and Cochrane Oral Health Group databases. The inclusion criteria were prospective studies that documented soft tissue thickness with direct intraoperative measurements and that included at least 1 year of follow-up. When possible, a meta-analysis was performed for both the overall and subgroup analyses. Results: Thirteen papers fulfilled the inclusion criteria. A meta-analysis of 7 randomized clinical trials was conducted. Significantly less bone loss was found around implants with thick mucosa than around those with thin mucosa (difference, -0.53 mm; P<0.0001). Subgroups were analyzed regarding the apico-coronal positioning, the use of platform-matched vs. platform-switched (PS) connections, and the use of cement-retained vs. screw-retained prostheses. In these analyses, thick mucosa was found to be associated with significantly less MBL than thin mucosa (P<0.0001). Among non-matching (PS) connections and screw-retained prostheses, bone levels were not affected by mucosal thickness. Conclusions: Soft tissue thickness was found to be correlated with MBL except in cases of PS connections used on implants with thin tissues and screw-retained prostheses. Mucosal thickness did not affect implant survival or the occurrence of biological or aesthetic complications.

ANALYSIS OF A REVERSED TRAPEZOIDAL FIN USING A 2-D ANALYTIC METHOD

  • Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제14권3호
    • /
    • pp.151-161
    • /
    • 2010
  • A reversed trapezoidal fin is analyzed using a two-dimensional analytical method. Heat loss from the reversed trapezoidal fin is presented as a function of the fin shape factor, fin base thickness and the fin base height. The relationship between the fin tip length and the convection characteristic number as well as that between the fin tip length and the fin base height for equal amounts of heat loss are analyzed. Also the relationship between the fin base thickness and the fin shape factor for equal amount of heat loss is presented. One of the results shows that the heat loss decreases linearly with the increase of the fin shape factor.

삼각 핀의 해석과 고정된 핀 바닥 높이에 기준한 최적화 (Analysis and Optimization based on the Fixed Fin Base Height for a Triangular Fin)

  • 강형석
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.13-19
    • /
    • 2007
  • A triangular fin with variable fin base thickness and base height is analyzed and optimized for the fixed fin base height using a two-dimensional analytical method. At the middle of the fin length, the variation of the temperature along the fin height is listed. The influences of the fin length, base thickness and base height on the heat loss and fin efficiency are analyzed, The optimum heat loss, corresponding optimum efficiency and optimum fin length as a function of the fin base thickness are presented. The optimum heat loss and optimum fin tip length as a function of the convection characteristic number are represented.

  • PDF