• 제목/요약/키워드: thickness control

검색결과 2,787건 처리시간 0.03초

연속압연기에서 OFF GAUGE 저감을 위한 DYNAMIC SET-UP 제어기술 (DYNAMIC SET-UP CONTROL OF TANDEM COLD MILL)

  • 노호섭;최병조;조뇌하;이재훈;김익준;진철제;박기영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.126-131
    • /
    • 1999
  • In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.

  • PDF

Keratinocyte Proliferation in Aged Rat Skin by High Voltage Pulsed Current Stimulation

  • Lee Jae-Hyoung;Lee Jong-Sook;Kil Eyn-Young
    • 대한의생명과학회지
    • /
    • 제10권4호
    • /
    • pp.361-366
    • /
    • 2004
  • The purpose of this study was to determine the effect of high voltage pulsed current (HVPC) stimulation on proliferative activities of basal keratinocytes by measured nucleolar organizer region (NOR) expression and thickness of spinous layer in aged rat skin. Fifty-one weeks old twelve male Sprague-Dawley rats (300∼350g) were divided into control and HVPC stimulation groups. Each animal's hair on the back were removed. The HVPC stimulation group received an negative monophasic twin peak pulsed current stimulation with 50 V, while the control group was given the same treatment without electricity. The rats were sacrificed after 3 weeks. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with hematoxyline-eosin and silver nitrate. The thickness of basal to granular layer of the epidennis were measured using a light microscope and computerized image analysis system. The number of argyrophilic nucleolar organizer region (AgNOR) were counted using a light microscope and computerized image analysis system and calculated as the mean number of AgNOR per nucleus in the basal keratinocyte. By using a Student's t-test, an increase in the thickness of basal-spinous layer (P<0.001) of epidermis can be observed in HVPC stimulation rats as compared with the control rats, whereas the thickness of the granular layer is not affected. A Student's t-test showed a significantly higher mean NOR number per nucleus of the basal keratinocyte in the HVPC stimulation rats than control rats (P<0.001). There was significantly positive correlation between the NOR number and the thickness of basal-spinous layer (r=0.80, P<0.05). These results suggest that the HVPC stimulation may increase the thickness of spinous layer in the epidennis due to increased proliferative activities of basal keratinocytes in epidennis in aged rat skin.

  • PDF

잔존 상아질 후경에 따른 S. mutans의 성견 치수반응에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF S. MUTANS ON THE PULP IN RELATION TO THE REMAINING DENTIN THICKNESS)

  • 김형동
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.34-45
    • /
    • 1990
  • The purpose of this study was to evaluate the pulpal responses of S. mutans (6715, serotype A) in relation to the remaining dentin thickness. The material was consisted of 72 teeth from 6 dogs. Cl. V cavities were prepared into 2 different thickness (0.5mm, 1.0mm) of remaining dentin. In the control groups, the cavities were filled with filter paper of broth, tin foil, and IRM$^{(R)}$ cement. In the experimental groups, the cavities were filled with filter paper of S. mutans, filter paper of broth, tin foil, and IRM$^{(R)}$ cement. The intervals of observation period were 1 week, 3 weeks, and 8 weeks respectively after the experiment. The specimens were fixed with 10% formalin and decalcified in 5% nitric acid. All specimens were stained with Hematoxylin-Eosin and examined histopathologically under the microscope. The results were as follows. 1. The changes and congestion of odontoblastic layers were more frequent and lasting in the control group of 0.5mm than in that of 1.0mm remaining dentin thickness. 2. There was no characteristic difference between the control group of 1.0mm and the experimental group of 1.0mm in all pulp responses. 3. Acute and chronic inflammatory cells were seen in the experimental group of 0.5mm, but not seen in the control group of 0.5mm.

  • PDF

Effect of Thermal Annealing on Nanoscale Thickness and Roughness Control of Gravure Printed Organic Light Emitting for OLED with PVK and $Ir(ppy)_3$

  • Lee, Hye-Mi;Kim, A-Ran;Kim, Dae-Kyoung;Cho, Sung-Min;Chae, Hee-Yeop
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1511-1514
    • /
    • 2009
  • Organic light emitting layer in OLED device was formed by gravure printing process in this work. Organic surface coated by gravure printing typically showed relatively bad uniformity. Thickness and roughness control was characterized by applying various mixed solvents in this work. Poly (N-vinyl carbazole) (PVK) and fact-tris(2-phenylpyridine)iridium($Ir(ppy)_3$) are host dopant system materials. PVK was used as a host and Ir(ppy)3 as green-emitting dopant. To luminance efficiency of the plasma treatment on etched ITO glass and then PEDOT:PSS spin coated. The device layer structure of OLED devices is as follow Glass/ITO/PEDOT:PSS/PVK+Ir(ppy)3-Active layer /LiF/Al. It was printed by gravure printing technology for polymer light emitting diode (PLED). To control the thickness multi-printing technique was applied. As the number of the printing was increased the thickness enhancement was increased. To control the roughness of organic layer film, thermal annealing process was applied. The annealing temperature was varied from room temperature, $40^{\circ}C$, $80^{\circ}C$, to $120^{\circ}C$.

  • PDF

Synchronous Vibration Control of a Rigid Rotor System using Active Air Bearing

  • Kwon, Tae-Kyu;Qiu, Jin-Hao;Tani, Jun-Ji;Lee, Seong-Cheol
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권2호
    • /
    • pp.87-94
    • /
    • 2002
  • This paper presents the synchronous vibration control of a rotor system using an Active Air Bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by the pivots containing piezoelectric actuators and their radial positions can be actively controlled by applying voltage to the actuators. Disturbances and various kinds of external forces can cause the shaft vibration as well as the change of the air film thickness. The dynamic behaviors of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The PID controller is applied to the tilting-pad gas bearing system with three pads, two of which contain piezoelectric actuators. To test the validity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

능동 공기 베어링에 의한 로터계 동기진동의 PID제어 (PID Control of a Synchronous Rotor System Vibration with Active Air Bearing)

  • 권대규;이영춘;이성철
    • 한국정밀공학회지
    • /
    • 제18권8호
    • /
    • pp.32-39
    • /
    • 2001
  • This paper presents the synchronous vibration control of a rotor system using an Active Air Bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by the pivots containing piezoelectric actuators and their radial positions can be actively controlled by applying voltage to the actuators. Disturbances and various kinds of external force can cause the shaft vibration as well as the change of the air film thickness. The dynamic behaviors of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The PID controller is applied to the tilting-pad gas bearing system with three pads, two of which contain piezoelectric actuators. To test the vapidity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

  • PDF

PZT 액추에이터를 이용한 로터계 동기진동의 강인제어 (Robust Control of Synchronous Vibration of a Rotor System with PZT Actuator)

  • 권대규
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.711-719
    • /
    • 2002
  • This paper presents the synchronous vibration control of a rotor system using an active air bearing(AAB). In order to suppress the synchronous vibration, it is necessary to actively control the air film pressure or the air film thickness. In this study, active pads are used to control the air film thickness. Active pads are supported by pivots containing piezoelectric actuators and their radial position can be actively controlled by applying voltage to the actuators. Thus, disturbances, i. e. various kinds of external force can cause shaft vibration as well as change of the air film thickness. The dynamic behavior of a rotary system supported by two tilting-pad gas bearings and its active stabilization using the tilting-pads as actuators are investigated numerically. The $\mu$ synthesis are applied to the AAB system with three pads, two of which contain piezoelectric actuators. To test the validity of the theoretical method, the performance of this control method is evaluated through experiments. The experimental results also show the effectiveness of the control system for suppressing the unbalanced response of the rigid modes.

Coating deviation control in traverse direction in a continuous galvanizing line

  • Yoo, Seung-Ryeol;Choi, Il-Seop;Kim, Sang-Jun;Park, Han-Ku;Kwak, Young-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.323-327
    • /
    • 1995
  • A new air knife system for coating thickness control in hot dip galvanizing process had been developed and installed on the CGL in Pohang Steel Works, POSCO. This new system consists of air knives with remotely adjustable nozzle slot and an automatic control system which can control both longitudinal and traverse coating deviations. Based on the optimal control algorithm, a traverse coating deviation control was designed. The controller controls the lip profile of the air knives with flexible structure according to the deviation of coating weight. From the measured values which are dependent on the strip width, the lip gaps are calculated with optimal algorithm and the model of the coating deviation. Time delay between knives and a coating thickness gauge is solved by the Smith Predictor.

  • PDF

플랭크 운동이 경한 만성 요통 대상자의 복부 근육 두께와 장애에 미치는 영향 (Effects of Plank Exercise on Abdominal Muscle Thickness and Disability in Subjects With Mild Chronic Low Back Pain)

  • 정혜진;하수진;정예지;조우현;김준기;원종임
    • 한국전문물리치료학회지
    • /
    • 제26권1호
    • /
    • pp.51-59
    • /
    • 2019
  • Background: Chronic low back pain (CLBP) causes morphological changes in muscles, reduces muscle strength, endurance and flexibility, negatively affects lumbar stability, and limits functional activity. Plank exercise strengthens core muscles, activates abdominal muscles, and improves intra-abdominal pressure to stabilize the trunk in patients with CLBP. Objects: We investigated the effect of plank exercise on abdominal muscle thickness and disability in patients with CLBP. Methods: We classified 33 subjects into 2 groups: An experimental (n1=17) and a control group (n2=16). Patients in the experimental group participated in plank exercise and those in the control group participated in stretching exercise. Patients in both groups attended 20-minute exercise sessions thrice a week for 4 weeks. Abdominal muscle thickness in each subject was evaluated ultrasonographically, and disabilities were assessed using the Oswestry disability index (ODI). Results: Four weeks later, abdominal muscle thickness showed a significant increase over baseline values in both groups (p<.05). Patients in the experimental group reported a more significant increase in the thickness of the external oblique muscle than that in the control group (p<.05). ODI scores in the experimental group were significantly lower after intervention than before intervention (p<.05). Conclusion: Plank exercise increases the thickness of the external oblique muscle and reduces disability secondary to mild CLBP. Therefore, plank exercise is needed to improve lumbar stability and functional activity in patients with mild CLBP.

석탄 가스화 복합 발전 플랜트의 분류층 가스화기 제어를 위한 선형 모델 예측 제어 기법 (Linear Model Predictive Control of an Entrained-flow Gasifier for an IGCC Power Plant)

  • 이효진;이재형
    • Korean Chemical Engineering Research
    • /
    • 제52권5호
    • /
    • pp.592-602
    • /
    • 2014
  • 석탄 가스화 복합 발전(coal-based IGCC power plant)에서 가스화기의 동적 상태와 성능이 플랜트 전체에 큰 영향을 미치므로, 가스화기가 문제 없이 운전 되도록 제어 하는 것은 전체 플랜트의 가동률을 높이는 데 있어 매우 중요한 일이라 할 수 있다. 가스화기의 안정적인 운전을 위해서는 고체 슬래그 층의 두께가 일정하게 유지되어야 하는데, 고체 슬래그 두께는 실시간 측정이 불가능하기 때문에 상태를 추정하여 추론 제어해야 한다. 본 연구에서는 Shell-type 가스화기의 동적 모사 모델을 개발하고 다변수 시스템의 추론 제어를 위한 방법으로 두 가지 선형 예측 제어 기법을 적용하여 그 특성을 분석하였다. 측정되지 않는 변수의 상태 추정을 위해 Kalman 필터 기법을 이용하였다. 측정 불가능한 1차 변수를 대신하여 측정 가능한 2차 변수를 제어하는 전통적인 추론 제어 기법으로는 외란의 종류에 따라 추론 제어가 불가능 할 수 있음을 확인하였고, 측정되지 않는 슬래그 두께를 Kalman 필터 기법을 이용하여 추정하여 성능 예측에 반영하고 외란 모델을 사용하여 예측 제어하는 경우 두 가지 측정 불가능한 외란 모두에 대해 추론 제어가 가능함을 확인하였다.