• Title/Summary/Keyword: thick and thin effect

Search Result 308, Processing Time 0.024 seconds

Effect of Deposition Temperature on the Characteristics of Low Dielectric Fluorinated Amorphous Carbon Thin Films (증착온도가 저유전 a-C:F 박막의 특성에 미치는 영향)

  • Park, Jeong-Won;Yang, Sung-Hoon;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1211-1215
    • /
    • 1999
  • Fluorinated amorphous carbon (a-C:F) films were prepared by an electron cyclotron resonance chemical vapor deposition (ECRCVD) system using a gas mixture of $C_2F_6$ and $CH_4$ over a range of deposition temperature (room temperature ~ 300$^{\circ}C$). 500$^{\AA}C$ thick DLC films were pre-deposited on Si substrate to improve the strength between substrate and a-C:F film. The chemical bonding structure, chemical composition, surface roughness and dielectric constant of a-C:F films deposited by varying the deposition temperature were studied with a variety of techniques, such as Fourier transform infrared spectroscopy(FTIR), X-ray photoelectron spectroscopy(XPS), atomic force microscopy (AFM) and capacitance-voltage(C-V) measurement. Both deposition rate and fluorine content decreased linearly with increasing deposition temperature. As the deposition temperature increased from room temperature to 300$^{\circ}C$, the fluorine concentration decreased from 53.9at.% down to 41.0at.%. The dielectric constant increased from 2.45 to 2.71 with increasing the deposition temperature from room temperature to 300$^{\circ}C$. The film shrinkage was reduced with increasing deposition temperature. This results ascribed by the increased crosslinking in the films at the higher deposition temperature.

  • PDF

Ion Transmittance of Anodic Alumina for Ion Beam Nano-patterning (이온빔 나노 패터닝을 위한 양극산화 알루미나의 이온빔 투과)

  • Shin S. W.;Lee J-H;Lee S. G.;Lee J.;Whang C. N.;Choi I-H;Lee K. H.;Jeung W. Y.;Moon H.-C.;Kim T. G.;Song J. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.97-102
    • /
    • 2006
  • Anodic alumina with self-organized and ordered nano hole arrays can be a good candidate of an irradiation mask to modify the properties of nano-scale region. In order to try using porous anodic alumina as a mask for ion-beam patterning, ion beam transmittance of anodic alumina was tested. 4 Um thick self-standing AAO templates anodized from Al bulk foil with two different aspect ratio, 200:1 and 100:1, were aligned about incident ion beam with finely controllable goniometer. At the best alignment, the transmittance of the AAO with aspect ratio of 200:1 and 100:1 were $10^{-8}\;and\;10^{-4}$, respectively. However transmittance of the thin film AAO with low aspect ratio, 5:1, were remarkably improved to 0.67. The ion beam transmittance of self-standing porous alumina with a thickness larger than $4{\mu}m$ is extremely low owing to high aspect ratio of nano hole and charging effect, even at a precise beam alignment to the direction of nano hole. $SiO_2$ nano dot array was formed by ion irradiation into thin film AAO on $SiO_2$ film. This was confirmed by scanning electron microscopy that the $SiO_2$ nano dot array is similar to AAO hole array.

Seismic wave propagation through surface basalts - implications for coal seismic surveys (지표 현무암을 통해 전파하는 탄성파의 거동 - 석탄 탄성파탐사에 적용)

  • Sun, Weijia;Zhou, Binzhong;Hatherly, Peter;Fu, Li-Yun
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Seismic reflection surveying is one of the most widely used and effective techniques for coal seam structure delineation and risk mitigation for underground longwall mining. However, the ability of the method can be compromised by the presence of volcanic cover. This problem arises within parts of the Bowen and Sydney Basins of Australia and seismic surveying can be unsuccessful. As a consequence, such areas are less attractive for coal mining. Techniques to improve the success of seismic surveying over basalt flows are needed. In this paper, we use elastic wave-equation-based forward modelling techniques to investigate the effects and characteristics of seismic wave propagation under different settings involving changes in basalt properties, its thickness, lateral extent, relative position to the shot position and various forms of inhomogeneity. The modelling results suggests that: 1) basalts with high impedance contrasts and multiple flows generate strong multiples and weak reflectors; 2) thin basalts have less effect than thick basalts; 3) partial basalt cover has less effect than full basalt cover; 4) low frequency seismic waves (especially at large offsets) have better penetration through the basalt than high frequency waves; and 5) the deeper the coal seams are below basalts of limited extent, the less influence the basalts will have on the wave propagation. In addition to providing insights into the issues that arise when seismic surveying under basalts, these observations suggest that careful management of seismic noise and the acquisition of long-offset seismic data with low-frequency geophones have the potential to improve the seismic results.

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.

Autoradiographic Studies on the Inhibitory Effect of Dibutyryl Cyclic AMP on Mouse Oocyte Maturation in Vitro (Dibutyryl Cyclic AMP가 생쥐여포난자의 성숙에 미치는 억제효과에 관한 자기방사법적 연구)

  • Choi, Choon-Keun
    • Applied Microscopy
    • /
    • v.7 no.1
    • /
    • pp.21-43
    • /
    • 1977
  • This experiment was undertaken in order to localize the labeled dbcAMP (dibutyryl cyclic AMP) in oocytes whose development has been suppressed by cold dbcAMP for 6 or 19 hours in vitro. Mouse oocytes were obtained from the ovaries of 3-4 week old A strain female mice, by puncturing the Graafian follicles in the modified Krebs-Ringer bicarbonate salt solution under the dissecting microscope. Those oocytes which have intact germinal vesicle were cultured in the basic culture medium supplemented with 0.4% bovine serum albumin (BSA). Cultivation of the oocytes was carried out in a microtube developed by Cho (1974). The cultures were then incubated in a humidified 5% $CO_2$ incubator maintained at $37^{\circ}C$ for 6 or 19 hours (Donahue, 1968). DbcAMP was added to culture medium for a final concentration of 100ug/ml, and $^3H-dbc$ AMP (specific activity 13 Ci/mM) for a final concentration of $40{\mu}Ci/ml$ was also added to the medium. For electron microscopic autoradiography, those oocytes recovered from the culture were washed with phosphate buffer (pH 7.4), and immediately prefixed in a 2.5% glutaraldehyde overnight and postfixed for 2 hours at $4 ^{\circ}C$ in 1% osmium tetroxide in phosphate buffer with pH 7.4 (Palade, 1952). After fixation, the materials were dehydrated in graded alcohol series and embedded in Epon 812 mixture based on the standard procedures (Luft, 1961). The thin sections $600-700{\AA}$ thick were mounted on the grids of 200 meshes. The grids containing sections were coated with a nuclear emulsion Kodak NTB-3 and stored in a cold dark box (at $4^{\circ}C$) for 3 weeks. After exposure, the samples were developed with Kodak D-19 and stained with uranyl acetate and lead citrate. Routine observation was made with Hitachi HU-11E electron microsocope. The results of the observation were as followings: 1. It was found that the labeled dbcAMP penetrated the egg plasma membrane and dispersed at random in the cytoplasm. 2. It was also observed that most of the labeled dbcAMP was attached to microfibrillar lattices portion of the oocyte cytoplasm. There fore, it is presumed that the receptor of the dbcAMP is localized in the microfibrillar lattices of the oocyte. 3. It also seems that some other cell organells such as mitochondria, Golgi complex, cortical granules are not directly related to the action of the dbcAMP. 4. The labeled dbcAMP was neither observed in the membrane nor in the nucleus. Therefore, it seems that there is no relationship between the concentration of dbcAMP and the nuclear membranous permeability. 5. There was no difference in number of dbcAMP particles when oocytes were cultured for 6 hours and 19 hours. 6. However, it was observed that, in same of the oocytes suppressed in germinal vesicle by dbcAMP for 19 hours, cell organells were moved and concentrated to a small portion of the cytoplasm, and that the morphology of the organells greatly changed to an abnormal. form. Therefore, it is supposed that those oocytes were in the process of degeneration. From the above results, it is expected that dbcAMP penetrated the egg membrane and was bound to the receptor which seems to be located in the microfibrillar lattiees portion, and that this dbcAMP-receptor complex inhibited some enzyme system of the oocytes which are essential for the germinal vesicle breakdown.

  • PDF

Sputtering Yield and Secondary Electron Emission Coefficient(${\gamma}$) of the MgO, $MgAl_2O_4$ and $MgAl_2O_4/MgO$ Thin Film Grown on the Cu Substrate by Using the Focused Ion Beam (Cu 기판위에 성장한 MgO, $MgAl_2O_4$$MgAl_2O_4/MgO$ 박막의 집속이온빔을 이용한 스퍼터링수율 측정과 이차전자방출계수 측정)

  • Jung K.W.;Lee H.J.;Jung W.H.;Oh H.J.;Park C.W.;Choi E.H.;Seo Y.H.;Kang S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.395-403
    • /
    • 2006
  • It is known that $MgAl_2O_4$ has higher resistance to moisture than MgO, in humid ambient MgO is chemically unstable. It reacts very easily with moisture in the air. In this study, the characteristic of $MgAl_2O_4$ and $MgAl_2O_4/MgO$ layers as dielectric protection layers for AC- PDP (Plasma Display Panel) have been investigated and analysed in comparison for conventional MgO layers. MgO and $MgAl_2O_4$ films both with a thickness of $1000\AA$ and $MgAl_2O_4/MgO$ film with a thickness of $200/800\AA$ were grown on the Cu substrates using the electron beam evaporation. $1000\AA$ thick aluminium layers were deposited on the protective layers in order to avoid the charging effect of $Ga^+$ ion beam while the focused ion beam(FIB) is being used. We obtained sputtering yieds for the MgO, $MgAl_2O_4$ and $MgAl_2O_4/MgO$ films using the FIB system. $MgAl_2O_4/MgO$ protective layers have been found th show $24{\sim}30%$ lower sputtering yield values from 0.244 up to 0.357 than MgO layers with the values from 0.364 up to 0.449 for irradiated $Ga^+$ ion beam with energies ranged from 10 kV to 14 kV. And $MgAl_2O_4$ layers have been found to show lowest sputtering yield values from 0.88 up to 0.109. Secondary electron emission coefficient(g) using the ${\gamma}$- FIB. $MgAl_2O_4/MgO$ and MgO have been found to have similar g values from 0.09 up to 0.12 for indicated $Ne^+$ ion with energies ranged from 50 V to 200 V. Observed images for the surfaces of MgO and $MgAl_2O_4/MgO$ protective layers, after discharge degradation process for 72 hours by SEM and AFM. It is found that $MgAl_2O_4/MgO$ protective layer has superior hardness and degradation resistance properties to MgO protective layer.

A Study on Direct Sowing Culture of Scutellaria baicalensis GEORGE Cultivated after Barley (황금의 맥후작 직파 재배 연구)

  • 권병선;신종섭
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2001.11b
    • /
    • pp.49-61
    • /
    • 2001
  • This study was carried out to determine the effect of various fertilizer levels, sowing time and planting density on the growth and yield of Scuteliaria baicalensis GEORGE cultivated after the barley in the southern coastal areas of Korea under the non- mulching condition by direct sowing culture. The flowering date of medium dressing plot(N : P$_2$O$\sub$5/ : K$_2$O=9 : 13.5 : 9kg/10a) and heavy dression plot(N : P$_2$O$\sub$5/, : K$_2$O=12 :18 : 12kg/10a) were July 23. The flowering date of the medium and the heavy dressing plot was delayed by 3days compared with that of non-fertilizing plot. The growth characteristics such as stem length, diameter of main stem, number of branch per plant, main root length, main root length, main root thickness and dry weight of stem leaves were more increased at medium dressing plot than that of other fertilizer levels, The root dry weight of in Scutellaria baicalensis GEORGE cultivated after barley was hlghest at the fertilizing plot of N : P$_2$O$\sub$5/ : K$_2$O=9 : 13.5 : 9kg/10a. The dried-root yield was 178kg in medium dressing plot, 167kg in standard dressing pot, and 126kg in non-dressing plot, The dried-root yield of medium dressing plot was 7% and 41 cie higher than that of standard dressing pot and non-dressing control plot, respectively. Emergence and flowering dates in the sowing time of June 1 were earlier than those of the other sowing times. In the sowing time of June 1, length and diameter of main stem, number of node per main stem, number of branch per plant and dry weight of stem leaves were greater than those of sowing times of June 10 and June 20. Yield components such as main stem length and diameter, main stem numbers, branches per plant, dry weight of stem leaves, main root length and thickness, number of large root and fine root per plant, and dry weight of root were the highest at the sewing time of June 1 as the yield of 71.3kg/10a. Optimum sowing time of Scuteilaria baicaiensis GEORGE cultivated after barley was June 1 in southern areas of Korea. Stem length was long in dense planting of 20${\times}$10cm and short in spacious planting of 30${\times}$10cm and 40${\times}$10cm by direct sowing cultivated after barley. Stem diameter was thick in spacious planting of 30${\times}$10cm and 40${\times}$10cm and was thin in dense planting of 20${\times}$10cm by direct sowing cultivated after barley. Length and dry weight of root per plant were decreased in dense planting of 20${\times}$10cm and were increased in spacious planting of 30${\times}$10cm and 40${\times}$10cm by direct sowing cultivated after barley. Yield of dry root was highest in optimum planting density(30${\times}$10cm 33 plants/㎡) by direct sowing cultivated after barley. The correlation coefficient between number of planting plant and stem length showed highly positive correlation. These characters of stem diameter, number of branches, main root length and yield of dry root mentioned above showed negative correlations with planting plants.

  • PDF

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.