• Title/Summary/Keyword: thermographic image

Search Result 36, Processing Time 0.023 seconds

Correlation between Abdominal Fat Distribution and Abdominal Temperature in Korean Premenopausal Obese Women

  • Song, Eun-Mo;Kim, Eun-Joo;Kim, Koh-Woon;Cho, Jae-Heung;Song, Mi-Yeon
    • The Journal of Korean Medicine
    • /
    • v.34 no.2
    • /
    • pp.1-9
    • /
    • 2013
  • Objectives: Considering that homeothermy is a major component of metabolic rate, body temperature might play a role in the pathophysiology of obesity. This study aimed to determine the relationship between abdominal fat distribution and abdominal temperature in Korean, premenopausal, obese women. Methods: Weight and height were measured in 26 premenopausal, obese women to calculate body mass index (BMI). Obesity was defined as a $BMI{\geq}25kg/m^2$. Waist circumference (WC) was also measured as well as abdominal fat by computed tomography (CT) and abdominal temperature by digital infrared thermographic imaging (DITI). Results: Visceral abdominal fat area was found to have a significant negative correlation with the temperature of Guanyuan (CV4, lower abdomen acupoint). We also found the visceral-subcutaneous fat ratio had a significant negative correlation with the temperature of CV4 and Right Tianshu (RST25, lateral navel acupoint). Only visceral fat and its ratio to subcutaneous fat had a significant correlation with abdominal temperature. Subcutaneous fat area and total fat area were not correlated with abdominal temperature. Conclusions: This study suggests that abdominal visceral fat has a significant negative correlation with abdominal temperature. Further study is needed to uncover the relationship between abdominal fat distribution and temperature regulation in obese individuals and to define the role of body temperature in the pathogenesis of obesity.

Study on the possibility of Digital Infrared Thermographic Imaging as a prognosis evaluation tool for patients with facial palsy (안면신경마비 환자의 예후 평가 도구로서의 적외선 체열 촬영(DITI - Digital Infrared Thermographic Imaging) 가능성에 대한 연구)

  • Bae, Hyo-Bin;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.3
    • /
    • pp.62-75
    • /
    • 2017
  • Objectives : The aim of this study is to evaluate possibility of DITI as prognosis evaluation tool of facial palsy. Methods : We investigate prognosis of facial palsy through EMR(Electronic Medical Record) of inpatient from December 2016 to June 2017. We evaluated the sex, age distribution, length of hospital stay, paralysis site, number of treatment after discharge, change of H-B Grade at entrance and exit, temperature difference of both sides of DITI, and Nerve Conduction Study(NCS) with reference to EMR recorded symptom change. Results : 1. Significant correlations were not found between DITI and House-Brackmann Grade change, NCS(%), the date of admission. 2. There was a negative correlation between NCS(%) and hospitalization period in patients with facial palsy. The higher the NCS, the faster the recovery rate of facial palsy. 3. In patients with facial palsy, the temperature difference between the two sides after the DITI image shows that the affected side tends to be lower than the normal side. Conclusions : In this study, only DITI temperature difference between both sides of face is not significant in determining the prognosis of facial palsy. Further research is needed to conduct DITI at the same time and to improve accuracy through a sufficient assessment of the degree of facial palsy.

Comparison of the Diagnostic Validity of Real and Absolute Skin Temperature Differences for Complex Regional Pain Syndrome (복합부위통증증후군 진단 시 좌우 체온 차이의 실제값과 절대값의 진단적 타당도 비교)

  • Nahm, Francis Sahngun;Lee, Pyung Bok;Park, Soo Young;Kim, Yong Chul;Lee, Sang Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.146-150
    • /
    • 2009
  • Background: A skin temperature difference is one of the variables used in the diagnosis of complex regional pain syndrome. However, there have been no reports as to whether the real (${\Delta}T$) or absolute value ($|{\Delta}T|$) of skin temperature differences should be used in the diagnosis of complex regional pain syndrome. This study was conducted to compare the diagnostic validity of ${\Delta}T$ with $|{\Delta}T|$ for complex regional pain syndrome using receiver operating characteristic curves (ROC). Methods: Infrared thermographic images were obtained from the 144 patients who were suspected to have CRPS in a unilateral limb. After ${\Delta}T$ and $|{\Delta}T|$ calculation from the thermographic image, ROCs of ${\Delta}T$ and $|{\Delta}T|$ were developed, and the areas under the curve (AUC) for the ROC curves were compared. Results: AUCs of ${\Delta}T$ and $|{\Delta}T|$ were 0.520 and 0.746 respectively, this difference was statistically significant (P < 0.001). Conclusions: Absolute skin temperature difference shows greater validity in the diagnosis of CRPS than ${\Delta}T$. Therefore, $|{\Delta}T|$ is more useful when comparing the skin temperature of CRPS patients.

Measurement Uncertainty on Subsurface Defects Detection Using Active Infrared Thermographic Technique (능동 적외선열화상 기법을 이용한 이면결함 검출에서의 측정 불확도)

  • Chung, Yoonjae;Kim, Wontae;Choi, Wonjae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.341-348
    • /
    • 2015
  • Active infrared thermography methods have been known to possess good fault detection capabilities for the detection of defects in materials compared to the conventional passive thermal infrared imaging techniques. However, the reliability of the technique has been under scrutiny. This paper proposes the lock-in thermography technique for the detection and estimation of artificial subsurface defect size and depth with uncertainty measurement.

The effects on the thermal changes of an acupuncture point area with the Young-Su-Bo-Sa(迎隨補瀉)-Acupuncture stimulation (영수보사(迎隨補瀉) 침자극(鍼刺戟)이 경혈영역(經穴領域)의 온도변화(溫度變化)에 미치는 영향(影響))

  • Lee, Seung-woo;Lee, Jeoung-hoon;Song, Beom-Yong;Yook, Tae-han
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.161-174
    • /
    • 2001
  • Purpose : This study is to see the existence of the meridian and the meridian point through their response to the Young-Su-Bo-Sa. Objective and Methods : For this purpose, with acupuncture stimulation with Young-Su-Bo-Sa on the Hapkok of left hand and an the non-meridian point, and using the Digital infrared thermal image(D.I.T.I), We observed and analyzed the thermal changes of Hapkok, Samgan, non-meridian point(NA), Yonghyang, Soryo, Chonchu, Shingwol. Results and Conclusions : To sum up, We could understand Young-Su-Bo-Sa stimulation through the study findings that the acupuncture stimulation on the meridian point caused significant thermal changes of the associated meridian and meridian point, and Young-Su-Bo stimulation given in the direction of the meridian passage caused increases in the thermal changes of the associated meridian point, while Young-Su-Sa stimulation caused decreases in the thermal changes of the associated meridian point.

  • PDF

Heat transfer and flow characteristics of sweeping jet issued from rectangular nozzle with thin plate (박판이 부착된 사각노즐에서 분사되는 Sweeping jet의 유동 및 열전달 특성)

  • Kim, Donguk;Jung, Jae Hoon;Seo, Hyunduk;Kim, Hyun Dong;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.2
    • /
    • pp.58-66
    • /
    • 2019
  • This study investigated heat transfer and flow characteristics of a sweeping jet issued from a rectangular nozzle with a thin plate. A thin vertical aluminum plate was attached on outlet of fluidic oscillator to increase velocity of central area with Coanda effect and enhance heat transfer performance. From visualization and PIV experiments, sweeping jet with a thin plate has larger velocity distribution in center region than that of the normal sweeping jet while oscillating frequency is similar as the normal one. Thermographic phosphor thermometry method was used to visualize the temperature field and Nu distribution of plate with impinging sweeping jet with thin plate. Four Reynolds numbers and three jet-to-wall distances were selected as parameters. It is found that heat transfer performance in the low jet-to-wall spacing was enhanced as the cooled area was expanded. However, when the jet-to-wall spacing became greater than 8dh, heat transfer performance became similar due to reduced impinging velocity.

Prediction of the Vase Life of Cut Lily Flowers Using Thermography

  • Lee, Ja Hee;Choi, So Young;Park, Hye Min;Oh, Sang Im;Lee, Ae Kyung
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.3
    • /
    • pp.233-239
    • /
    • 2019
  • This study was conducted in order to predict the vase life of cut lily 'Woori Tower' flowers using a non-destructive thermal imaging technique. It was found that the temperature of cut lily flowers was maintained at 20℃ and was slightly lower than the air temperature until they bloomed. On the 11th day, when flowers bloomed, the temperature of leaves and flowers was measured to be 18.75±0.38℃ and 19.23±0.32℃ respectively, and their difference with ambient temperature was over 3℃. The flower temperature increased slightly when the vase life of cut lily flowers ended, and the temperature difference between the air and leaf temperature (1.77℃) and between the air and flower temperature (1.39℃) got smaller. No visible aging symptom was observed, but it was found that the temperature had risen due to water losses and less functional stomata. The vase life of cut lily flowers can be predicted based on changes in temperature and it will be also possible to predict the potential quality and vase life of cut flowers before harvesting them in greenhouses.

The Efficiency of External Heat Sources for Infrared Thermography Applied Concrete Structures and the Improvement of the Defect-identification (열화상 기법을 이용한 콘크리트 구조물 결함 검출시 열원의 효율 비교 및 결함검출 능력 향상)

  • Sim, Jun-Gi;Moon, Do-Young;Chung, Lan;Lee, Jong-Seh;Zi, Goangseup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.169-179
    • /
    • 2009
  • The purpose of this paper is to find an efficient heat source to amplify the surface temperature of damaged concrete structures for infrared thermography. we compare two different heat sources of far-infrared lamp and halogen lamp each other for their efficiency. The two heat sources were applied to the concrete specimens. Two different concrete specimens were used: one was the concrete containing internal void and the other was wrapped with partially unbonded fiber reinforced polymer sheet. it was found that the far-infrared lamp was more efficient than the halogen lamp. In addition, we propose a new algorithm to make the damage zone displayed clear in the image obtained from the thermographic operation. The algorithm is a combination of Gauss filtering process and the Prewitt mask operation.

The Usefulness of Three-phase Bone Scan and Thermography for Making the Diagnosis of CRPS-I (제1형 복합부위 통증증후군의 진단에서 적외선 체열측정과 3상 골스캔의 유용성)

  • Park, Sang Hyun;Lee, Pyung Bok;Lim, Yun Hee;Lee, Seung Yoon;Choi, In Yong;Lee, Sang Jin;Oh, Yong Seok
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • Background: Complex regional pain syndrome (CRPS) is a painful and disabling disease, yet the diagnosis of this can be difficult to confirm by purely objective measures. Therefore, we performed three-phasic bone scans and thermography as a work up in order to determine their predictive value and usefulness for making the diagnosis of CRPS. Methods: 44 patients who had been diagnosed with CRPS type-1, according to the modified criteria, were evaluated. All the patients were examined by performing a three-phasic bone scan and thermography as part of a work-up for diagnostic confirmation. The diffuse increased tracer uptake in the delayed image (phase III) was estimated by the positive findings. The findings were considered positive for CRPS if the thermographic findings showed temperature asymmetries between the affected and non- affected extremities of more than $1.00^{\circ}C$ Results: A review of the three-phasic bone scan for 44 patients indicated that 16 patients (36.4%) had diffusely positive scans, and thermographic abnormalities were noted in 35 of 44 patients (79.5%). Conclusions: The use of thermography in clinical settings can play an important role in the diagnosis of CRPS. However, a three-phasic bone scan alone cannot provide a completely accurate diagnosis, so it is imperative that the three-phasic bone scan data be integrated with the clinical evaluation and the other relevant tests.

A Study on the Change of Body Temperature according to the Needle Remaining Time at LU9 - Through the D.I.T.I. Scan - (태연혈(太淵穴)의 유침 시간에 따른 체온 변화 -적외선체열촬영(赤外線體熱撮影)을 중심으로-)

  • Lee, Bong-Hyo;Lee, Kyung-Min;Park, Ji-Ha;Kim, Min-Seo;Kim, San-Deul;Park, Byeong-Gyu;Yang, Hyun-Dong;Yea, Sung-Ho;Lee, Ho-Jung;Choi, Jae-Won;Hong, Hye-Lin;Lee, Eun-Jung;Lim, Sung-Chul;Kim, Jae-Su;Lee, Yun-Kyu;Lee, Hyun-Jong;Jung, Tae-Young;Jung, Hyun-Jung;Kam, Chul-Woo
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.188-199
    • /
    • 2012
  • Objectives : This study was performed to find the desirable remaining time of needle in the acupuncture treatment. Methods : The 21 volunteers were given acupuncture at LU9 vertically and needles were remained for 2 min, 10 min, 15 min, 30 min, respectively. The thermographic change induced by acupuncture was measured with Digital Infrared Thermographic Image at the following acupoints: LU11, LU10, LU9, LU8, LU5, LU1, and PC7. The statistical significance of thermographic change was evaluated using paired t-test and post hoc Wilcoxon test. Results : The most significant changes after acupuncture were produced when needles were remained for 10 min or 15 min. LU11, LU5, LU1, and PC7 were the point at which all of the remaining time produced significant change commonly. At LU11, the biggest change was produced when needle was remained for 15 min, while at LU5, LU1, and PC7, the biggest change was produced when needle was remained for 30 min, and the smallest change was produced when needle was remained for 10 min at all of acupoints of LU11, LU5, LU1, and PC7. The unbalance between left side and right was decreased the most largely in 15 min group. Conclusions : The results of this study suggest that the desirable remaining time of acupuncture needle might be 15 min.