• Title/Summary/Keyword: thermal-flow

Search Result 3,613, Processing Time 0.033 seconds

Experimental Study on Auto-Transmission Fluid Heat Exchanger for Improving Vehicle Fuel Efficiency (차량 연비개선을 위한 자동변속기유 열교환기에 대한 실험적 연구)

  • Jang, Chung-Man;Lee, Yong-Kyu;Kang, Byeong-Dong;Yoo, Jai-Suk;Lee, Jong-Hwa;Kim, Hyun-Jung;Kim, Dong-Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.947-954
    • /
    • 2011
  • Drive-train friction loss in a vehicle may account for 4% of its total fuel consumption loss. An ATF W/C (auto-transmission fluid warmer/cooler) plate-fin heat exchanger is a type of heat exchanger that uses metal plates to transfer heat between the auto-transmission fluid and coolant. The use of an ATF W/C heat exchanger can result in a fuel economy improvement of about 1% in vehicles. An experimental setup for testing the thermal performance of an ATF W/C plate-fin heat exchanger is developed. In this study, the influence of the ATF and coolant, flow rates, and temperature on the efficiency of an ATF W/C heat exchanger are investigated experimentally. From the experimental data, a simple correlation for predicting the efficiency of an ATF W/C heat exchanger is proposed. On the basis of this correlation, the fuel economy of a vehicle with and without an ATF W/C heat exchanger is compared by using Simulink. Finally, it is shown that the fuel economy is improved by 0.992% when an ATF W/C heat exchanger is installed in the vehicle.

Improved Electrical Properties by In Situ Nitrogen Incorporation during Atomic Layer Deposition of HfO2 on Ge Substrate (Ge 기판 위에 HfO2 게이트 산화물의 원자층 증착 중 In Situ 질소 혼입에 의한 전기적 특성 변화)

  • Kim, Woo-Hee;Kim, Bum-Soo;Kim, Hyung-Jun
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.14-21
    • /
    • 2010
  • Ge is one of the attractive channel materials for the next generation high speed metal oxide semiconductor field effect transistors (MOSFETs) due to its higher carrier mobility than Si. But the absence of a chemically stable thermal oxide has been the main obstacle hindering the use of Ge channels in MOS devices. Especially, the fabrication of gate oxide on Ge with high quality interface is essential requirement. In this study, $HfO_xN_y$ thin films were prepared by plasma-enhanced atomic layer deposition on Ge substrate. The nitrogen was incorporated in situ during PE-ALD by using the mixture of nitrogen and oxygen plasma as a reactant. The effects of nitrogen to oxygen gas ratio were studied focusing on the improvements on the electrical and interface properties. When the nitrogen to oxygen gas flow ratio was 1, we obtained good quality with 10% EOT reduction. Additional analysis techniques including X-ray photoemission spectroscopy and high resolution transmission electron microscopy were used for chemical and microstructural analysis.

Process Development for Production of Ultramarine Blue from Kaolin (고령토로부터 군청안료 제조)

  • Choi, Young-Yoon;Lee, Hoo-In;Kim, Byung-Su;Kim, Sang-Bae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.107-114
    • /
    • 2009
  • In present study, an alternative process for manufacturing ultra marine blue by using kaolin, sulfur, sodium carbonate, silica, and rosin was investigated. From the experiments, it was found in the reductive calcination process that the temperature variation with the bed height of input materials is relatively high due to the inadequate thermal conductivity of them. It was also found that the color of the ultramarine blue manufactured is sensitive for the shape of the input materials and the calcinations conditions, and specially the heating rate is very important to form ultramarine. For manufacturing green ultramarine by using sulfur, sodium carbonate, silicon, and pine resin, an optimum condition was investigated to be the heating rate region below $0.6^{\circ}C/min$, the reaction temperature of $850^{\circ}C$ and the reaction time of 4 hr. At the oxidative calcination process to manufacture ultra marine blue from green ultramarine, the optimum flow rate of air is $500{\sim}550\;{\ell}/kg$ (green ultramarine) and the reaction temperature is $500{\sim}550^{\circ}C$.

THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES (광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구)

  • Ryoo, Joo-Hee;Lee, In-Bog;Yoo, Hyun-Mee;Kim, Mi-Ja;Seok, Chang-In;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005 (환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.1-31
    • /
    • 2011
  • By employing Environmental Input-Output Table 2005, which has 76 intermediate sector and 21 energy sources, this paper analyses the flow of energy demand and $CO_2$ after estimating an induced $CO_2$ emissions from 76 industrial sectors. Index of $CO_2$ intensity($CO_2/GDP$) and other index of $CO_2$ intensity($CO_2/calory$) showed that final demand sector uses more high calory energy source. Intermediate sector used less environmental friendly energy source and emit more $CO_2$ at same calory. Industries those has high induced $CO_2$ emissions are Thermal Power($32.587CO_2-g/Won$), Cement($10.370CO_2-g/Won$), Road Transportation($7.255CO_2-g/Won$), Cokes and Other Coal Products($5.791CO_2-g/Won$), Steam and Hot water supply, Sewage, Sanitary services($4.575CO_2-g/Won$). It is shown that industry such as Iron and Steel which has low $CO_2$ intensity, high backward linkage effect and high forward linkage effect makes high induced $CO_2$ emissions. Environmental load and $CO_2$ emissions in overall economy will decrease when not high $CO_2$ intensity industry but also low $CO_2$ intensity industry makes lower $CO_2$ intensity.

  • PDF

Characteristic of Partial Oxidation of Methane and Ni Catalyst Reforming using GlidArc Plasma (GlidArc 플라즈마를 이용한 메탄 부분산화 및 Ni 촉매 개질 특성)

  • Kim, Seong-Cheon;Chun, Young-Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1268-1272
    • /
    • 2008
  • Low temperature plasma applied with partial oxidation is a technique to produce synthesis gas from methane. Low temperature plasma reformer has superior miniaturization and start-up characteristics to reformers using steam reforming or CO$_2$ reforming. In this research, a low temperature plasma reformer using GlidArc discharge was proposed. Reforming characteristics for each of the following variables were studied: gas components ratio (O$_2$/CH$_4$), the amount of steam, comparison of reaction on nickle and iron catalysts and the amount of CO$_2$. The optimum conditions for hydrogen production from methane was found. The maximum Hydrogen concentration of 41.1% was obtained under the following in this condition: O$_2$/C ratio of 0.64, total gas flow of 14.2 L/min, catalyst reactor temperature of 672$^{\circ}C$, the amount of steam was 0.8, reformer energy density of 1.1 kJ/L with Ni catalyst in the catalyst reactor. At this point, the methane conversion rate, hydrogen selectivity and reformer thermal efficiency were 66%, 93% and 35.2%, respectively.

A Study on Natural Ventilation by the Caloric Values of HLW in the Deep Geological Repository (지하처분장내 고준위 방사성 폐기물 발열량에 따른 자연환기력 연구)

  • Roh, Jang-Hoon;Choi, Heui-Joo;Yu, Yeong-Seok;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.21 no.6
    • /
    • pp.518-525
    • /
    • 2011
  • In this study, the natural ventilation pressure resulting from the large altitude difference which is a characteristic of high radioactive waste repository and the caloric value of the heat emitted by wastes was calculated and based on the results, natural ventilation quantities were calculated. A high radioactive waste repository can be considered as being operated through closed cycle thermodynamic processes similar to those of thermal engines. The heat produced by the heating of high radioactive wastes in the underground repository is added to the surrounding air, and the air goes up through the upcast vertical shaft due to the added heat while working on its surroundings. Part of the heat added by the work done by the air can be temporarily changed into mechanical energy to promote the air flow. Therefore, if a sustained and powerful heat source exists in the repository, the heat source will naturally enable continued cyclic flows of air. Based on this assumption, the quantity of natural ventilation made during the disposal of high radioactive wastes in a deep geological layer was mathematically calculated and based on the results, natural ventilation pressure of $74{\sim}183$Pa made by the stack effect was identified along with the resultant natural ventilation quantity of $92.5{\sim}147.7m^3/s$. The result of an analysis by CFD was $82{\sim}143m^3/s$ which was very similar to the results obtained by the mathematical method.

Formation and Characteristics of the Fluorocarbonated SiOF Film by $O_2$/FTES-Helicon Plasma CVD Method

  • Kyoung-Suk Oh;Min-Sung Kang;Chi-Kyu Choi;Seok-Min Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.77-77
    • /
    • 1998
  • Present silicon dioxide (SiOz) 떠m as intennetal dielectridIMD) layers will result in high parasitic c capacitance and crosstalk interference in 비gh density devices. Low dielectric materials such as f f1uorina뼈 silicon oxide(SiOF) and f1uoropolymer IMD layers have been tried to s이ve this problem. I In the SiOF ftlm, as fluorine concentration increases the dielectric constant of t뼈 film decreases but i it becomes unstable and wa않r absorptivity increases. The dielectric constant above 3.0 is obtain어 i in these ftlms. Fluoropolymers such as polyte$\sigma$따luoroethylene(PTFE) are known as low dielectric c constant (>2.0) materials. However, their $\alpha$)Or thermal stability and low adhesive fa$\pi$e have h hindered 야1리ru뚱 as IMD ma따"ials. 1 The concept of a plasma processing a찌Jaratus with 비gh density plasma at low pressure has r received much attention for deposition because films made in these plasma reactors have many a advantages such as go여 film quality and gap filling profile. High ion flux with low ion energy in m the high density plasma make the low contamination and go어 $\sigma$'Oss피lked ftlm. Especially the h helicon plasma reactor have attractive features for ftlm deposition 야~au똥 of i앙 high density plasma p production compared with other conventional type plasma soun:es. I In this pa야Jr, we present the results on the low dielectric constant fluorocarbonated-SiOF film d밑JOsited on p-Si(loo) 5 inch silicon substrates with 00% of 0dFTES gas mixture and 20% of Ar g gas in a helicon plasma reactor. High density 띠asma is generated in the conventional helicon p plasma soun:e with Nagoya type ill antenna, 5-15 MHz and 1 kW RF power, 700 Gauss of m magnetic field, and 1.5 mTorr of pressure. The electron density and temperature of the 0dFTES d discharge are measUI벼 by Langmuir probe. The relative density of radicals are measured by optic허 e emission spe따'Oscopy(OES). Chemical bonding structure 3I피 atomic concentration 따'C characterized u using fourier transform infrared(FTIR) s야3띠"Oscopy and X -ray photonelectron spl:’따'Oscopy (XPS). D Dielectric constant is measured using a metal insulator semiconductor (MIS;AVO.4 $\mu$ m thick f fIlmlp-SD s$\sigma$ucture. A chemical stoichiome$\sigma$y of 야Ie fluorocarbina$textsc{k}$영-SiOF film 따~si야영 at room temperature, which t the flow rate of Oz and FTES gas is Isccm and 6sccm, res야~tvely, is form려 야Ie SiouFo.36Co.14. A d dielec$\sigma$ic constant of this fIlm is 2.8, but the s$\alpha$'!Cimen at annealed 5OOt: is obtain려 3.24, and the s stepcoverage in the 0.4 $\mu$ m and 0.5 $\mu$ m pattern 킹'C above 92% and 91% without void, res야~tively. res야~tively.

  • PDF

Construction and Assembly of KSTAR Current Leads and the Helium Control System (KSTAR 전류인입선 및 헬륨냉매 제어시스템 제작 및 설치)

  • Song, N.H.;Woo, I.S.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, J.S.;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.388-396
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) current lead system (CLS) has a role to interconnect magnet power supply (MPS) in room temperature (300 K) and superconducting (SC) bus-line, electrically. For the first plasma experiments, it should be assembled 4 current leads (CL) on toroidal field (TF) current lead box (CLB) and 14 leads on poloidal field (PF) CLB. Two current leads, with the design currents 17.5 kA, and SC bus-lines are connected in parallel to supply 35 kA DC currents on TF magnet. Whereas, it could supply $20\;{\sim}\;26\;kA$ to each pairs of PF magnets during more than 350 s. At the cold terminals of the leads, there are joined SC bus-lines and it was constructed helium coolant control system, aside from main tokamak system, to protect heat flux through current leads and enhanced Joule heat due to supplied currents. Throughout the establishment processes, it was tested the high vacuum pumping, helium leak of the helium lines and hardwares mounted between the helium lines, flow controls for CL, and liquid nitrogen cool-down of possible parts (current leads, CL helium lines, and thermal shield helium lines for CLB), for the accomplishment of the required performances.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.