• Title/Summary/Keyword: thermal-flow

Search Result 3,613, Processing Time 0.034 seconds

Flow Analysis to Develop Uniform Thermal Flow Distributions of the Box Type Dryer for Agriculture Products (상자식 농수산물 건조기의 열풍 균일분배구조 실현을 위한 유동해석)

  • Eom Yong-Kyoon;Ahn Do-Won;Cheon Sung-Kook;Seo Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • Both the computational and experimental analysis have been conducted in this study to develop the high efficiency agriculture products dryer by the uniform thermal flow distribution in the drying room. It has been developed based on the results of the computation and experiment in the conventional dryer to improve the thermal flow distribution in drying room. The developed dryer can be prevented the local concentration of the heated wind and achieved the uniform flow distribution using the installation of vertical branch ducts, ribs, guide vanes and porous plates. As a result, the developed dryer reduced the fuel consumption up to $15\%$ and the electricity consumption up to $31.5\%$ compared with the conventional dryer.

A NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF GAS CHROMATOGRAPHIC COLUMN (가스 크로마토그래픽 컬럼의 유동특성에 대한 수치적 연구)

  • Kim T.-A.;Kim Youn J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.21-26
    • /
    • 2005
  • Gas Chromatography (GC) is a wisely technique used for the separation and analysis of liquid and gas sample. Separation of the sample vapors is achieved via their differential migration through a capillary column with an insert carrier gas. The identity and quantity of each vapor in the mixer can be determined from its retention time in the column and a particular property of the gas, such as thermal conductivity, which can be related to the concentration of sample vapor in the carrier gas. Therefore, the flow characteristics in the spiral gas chromatographic column are numerically investigated in this study. Especially, different pressure drop between the front and the rear of GC column with various flow rates is estimated the governing equations are derived from making using of three-dimensional Naver-Stokes equation with incompressible and laminar model due to the nature of low Reynolds number flow. Using a commercial code, FLUENT, the pressure and flow fields in GC column are calculated with various flow rates. The characteristics of thermal cycling which is one of the most important factors affecting the column efficiency and analysis time is also estimated. Furthermore, numerical analyses are also carried out by using commercial code, ANSYS, with various values of power, which is applied to the heating element located at lower GC column.

  • PDF

NUMERICAL STUDY ON THE PERFORMANCE CHARACTERISTICS OF SHELL AND TUBE HEAT EXCHANGER BY FLOW DISTRIBUTORS : PART(II) HEAT TRANSFER CHARACTERISTICS (유동분배판에 의한 원통-다관형 열교환기의 성능 특성에 관한 수치해석적 연구(II): 전열특성)

  • Park, Y.M.;Lee, T.H.;Chung, H.T.;Kim, H.B.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.28-32
    • /
    • 2016
  • In the previous study, it is proved by numerical simulation that the baffle shaped as the porous plate installed in the inlet chambers improves the redistribution of the flow injecting to the tube bundles. In the present study, numerical simulation has been performed to investigate the effects of the flow distributors on the thermal characteristics of the shell and tube heat exchangers. The flow fields have been analysed by the three-dimensional Navier-Stokes solvers including the thermal conditions on the shell sides. The numerical results showed that the presence of the baffles improves the redistribution of the heat transfer to the tube bundles though the overall performance drop slightly on the present flow conditions.

A Numerical Study on the Heat Transfer Characteristics in an Internally Finned Circular Tube Flow (내부핀이 부착된 원형관유동에서의 열전달특성에 관한 수치적연구)

  • Pak, H.Y.;Park, K.W.;Choi, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.267-278
    • /
    • 1996
  • Steady, laminar, forced convection flow and heat transfer in the entrance region of an internally finned circular duct with a finite thermal conductivity has been analyzed numerically. The problem under investigation is a three-dimensional boundary layer problem, and is solved by employing a marching-type procedure which involves solution of a series of 2-dimensional elliptic problems in the cross-stream plane. Two types of inlet hydrodynamic conditions are considered : (a) uniform velocity flow and (b) fully developed flow. From the above inlet conditions, the effects of the fin height(h), fin number(N) and conductivity ratio($k_r$) on the flow and thermal characteristics are investigated. The numerical results show that the height and number of fins, and ratio of the solid to fluid thermal conductivity have pronounced effect on the solution. Considering pressure drop, optimized dimensionless fin height is 0.4.

  • PDF

Simultaneous Measurement of Fluid Velocity and Particle Velocity in a Particle-Containing Fluid Flow (입자가 포함된 유동장에서 유체속도와 입자속도의 동시 측정기법)

  • Jin Dong-Xu;Lee Dae-Young;Lee Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2005
  • A novel method for simultaneously measuring the fluid velocity and the large particle velocity in a particle-containing fluid flow is developed in this study. In this method, the fluid velocity and the large particle velocity are measured by PIV and PTV, respectively. The PIV and PTV images are obtained from the same flow images. Since a PIV result represents the average displacement of all particles in an interrogation area, it will include an error caused by the relative displacement between the large particles and the fluid. In order to reduce the false influence of large particles on the PIV calculation, the mean brightness of small PIV particle images is substituted to the locations of large particles in the PIV images. The simulation results showed that the new method significantly reduces the PIV error caused by the large particles even at the case where the large particles occupy area fraction as large as $20\%$ of the full image.

Stability and nonlinear vibration of a fuel rod in axial flow with geometric nonlinearity and thermal expansion

  • Yu Zhang;Pengzhou Li;Hongwei Qiao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4295-4306
    • /
    • 2023
  • The vibration of fuel rods in axial flow is a universally recognized issue within both engineering and academic communities due to its significant importance in ensuring structural safety. This paper aims to thoroughly investigate the stability and nonlinear vibration of a fuel rod subjected to axial flow in a newly designed high temperature gas cooled reactor. Considering the possible presence of thermal expansion and large deformation in practical scenarios, the thermal effect and geometric nonlinearity are modeled using the von Karman equation. By applying Hamilton's principle, we derive the comprehensive governing equation for this fluid-structure interaction system, which incorporates the quadratic nonlinear stiffness. To establish a connection between the fluid and structure aspects, we utilize the Galerkin method to solve the perturbation potential function, while employing mode expansion techniques associated with the structural analysis. Following convergence and validation analyses, we examine the stability of the structure under various conditions in detail, and also investigate the bifurcation behavior concerning the buckling amplitude and flow velocity. The findings from this research enhance the understanding of the underlying physics governing fuel rod behavior in axial flow under severe yet practical conditions, while providing valuable guidance for reactor design.

The Effect of Turbulence Penetration on the Thermal Stratification Phenomenon Caused by Coolant Leaking in a T-Branch of Square Cross-Section

  • Choi, Young-Don;Hong, Seok-Woo;Park, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.51-60
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can occur due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, effects of turbulence penetration on the thermal stratification into T-branches with square cross-section in the modeled ECCS are analysed numerically. Standard k-$\varepsilon$ model is employed to calculate the Reynolds stresses in momentum equations. Results show that the length and strength of thermal stratification are primarily affected by the leak flow rate of coolant and the Reynolds number of duct. Turbulence penetration into the T-branch of ECCS shows two counteracting effects on the thermal stratification. Heat transport by turbulence penetration from main duct to leaking flow region may enhance thermal stratification while the turbulent diffusion may weaken it.

Numerical Investigation on Natural Circulation in a Simplified Passive Containment Cooling System (단순화된 피동 원자로건물 냉각계통 내 자연순환에 관한 수치적 연구)

  • Suh, Jungsoo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.92-98
    • /
    • 2018
  • The flow of cooling water in a passive containment cooling system (PCCS), used to remove heat released in design basis accidents from a concrete containment of light water nuclear power plant, was conducted in order to investigate the thermo-fluid equilibrium among many parallel tubes of PCCS. Numerical simulations of the subcooled boiling flow within a coolant loop of a PCCS, which will be installed in innovative pressurized-water reactor (PWR), were conducted using the commercially available computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the RPI model were used for turbulence closure and subcooled flow boiling, respectively. As the first step, the simplified geometry of PCCS with 36 tubes was modeled in order to reduce computational resource. Even and uneven thermal loading conditions were applied at the outer walls of parallel tubes for the simulation of the coolant flow in the PCCS at the initial phase of accident. It was observed that the natural circulation maintained in single-phase for all even and uneven thermal loading cases. For uneven thermal loading cases, coolant velocity in each tube were increased according to the applied heat flux. However, the flows were mixed well in the header and natural circulation of the whole cooling loop was not affected by uneven thermal loading significantly.

A CFD ANALYSIS FOR THERMAL MIXING IN A SUBCOOLED WATER UNDER TRANSIENT STEAM DISCHARGE CONDITIONS (과도상태 증기제트 방출시 과냉각수조 내의 열혼합 해석)

  • Kang H.S.;Kim Y.S.;Chun H.G.;Song C.H.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.8-18
    • /
    • 2006
  • A CFD benchmark calculation for a steam blowdown test was performed for 30 seconds to develop the methodology of numerical analysis for the thermal mixing between steam and subcooled water. In the CFD analysis, the grid model simulating the sparger and the IRWST pool were developed by the axisymmetric condition and then the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. Thermal mixing phenomenon in the subcooled water tank was treated as an incompressible flow, a free surface flow between the air and the water, a turbulent flow, and a buoyancy flow. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. The commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behavior reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted.

Numerical analysis of two experiments related to thermal fatigue

  • Bieder, Ulrich;Errante, Paolo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.675-691
    • /
    • 2017
  • Jets in cross flow are of fundamental industrial importance and play an important role in validating turbulence models. Two jet configurations related to thermal fatigue phenomena are investigated: ${\bullet}$ T-junction of circular tubes where a heated jet discharges into a cold main flow and ${\bullet}$ Rectangular jet marked by a scalar discharging into a main flow in a rectangular channel. The T-junction configuration is a classical test case for thermal fatigue phenomena. The Vattenfall T-junction experiment was already subject of an OECD/NEA benchmark. A LES modelling and calculation strategy is developed and validated on this data. The rectangular-jet configuration is important for basic physical understanding and modelling and has been analyzed experimentally at CEA. The experimental work was focused on turbulent mixing between a slightly heated rectangular jet which is injected perpendicularly into the cold main flow of a rectangular channel. These experiments are analyzed for the first time with LES. The overall results show a good agreement between the experimental data and the CFD calculation. Mean values of velocity and temperature are well captured by both RANS calculation and LES. The range of critical frequencies and their amplitudes, however, are only captured by LES.