• 제목/요약/키워드: thermal tank

검색결과 502건 처리시간 0.024초

Numerical study on CMT boron replenishment strategy for an AP1000 nuclear power unit

  • Wang, Hong;Zhang, Miao;Li, Jialong;Wang, Junpeng
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2321-2328
    • /
    • 2022
  • The passive safety system is adopted in an AP1000 nuclear power unit to improve the operation safety of the whole unit. However, due to boron diffusion and periodic sampling, boron dilution occurs in the core makeup tank. The boron replenishment process in the core makeup tank is essential and becomes particularly important. Based on the validated models, this article numerically investigates the influence of the replenishment flow rate and the position on the boron distribution in the core makeup tank. The thermal fatigue phenomenon of the "T" connection caused by replenishment is analyzed. Finally, the replenishment strategy is proposed to benefit both boron mixing in the core makeup tank and eliminating the thermal fatigue of the "T" connection.

가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR (Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank)

  • 서흥석;이영범;김동혁;박창원
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

태양열 온수 및 난방 일체형 복합시스템의 성능예측 (Performance Prediction of a Hot Water Supply and Panel Heating System with Solar Energy)

  • 한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, a simulation program was developed with heat transfer model in the thermal storage tank for a solar collector and burner combined heating and hot water supply system. Analysis was conducted with variation of operating condition and schedule to analyze performance of a hot water supply and panel heating system with a solar collector and burner combined thermal storage tank. The simulation program is divided two sections. One part is calculation of temperature variation of water which flows through the panel in the floor for heating of the residential house during 24 hours, and the other part is heat transfer calculation for the reaction time to get desired water temperature in the thermal storage tank. As results, light oil consumption and system performance during operation period were analyzed with variation of climate condition and with or without solar collector. Most of the case, oil could be saved about from 24 to 41% with installing the solar collector. The performance of the system is more dependent on radiation time of the solar collector rather than the intensity of the solar radiation which was adopted for the climate analysis.

성층화된 축열조의 1차원모델에 대한 해석적인 해 (Analytical Solutions to a One-Dimensional Model for Stratified Thermal Storage Tanks)

  • 유호선;박이동
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.42-51
    • /
    • 1995
  • In order to establish a theoretical basis for the analyses of transient behaviors in stratified thermal storage tanks, analytical approaches to an improved one-dimensional model are made. In the present model the storage tank is treated as a finite region with an adiabatic tank exit, whereas it has been considered as a simple semi-infinite region previously. Application of the Laplace transformation and the Inversion theorem to the governing equations makes it possible to obtain an exact infinite-series solution, which is convergent only at sufficiently large time. Accordingly a complementary solution which is available for short times, i.e., the time range of this study is sought by an approximate method. The approximate solution which is rigorously validated through the examination of neglected terms in the solution procedure agrees quite well with the exact one. Moreover, it is simpler to use and more convenient to interpret the physical meaning of the solution. Comparison of the present solution with the previous ones shows relatively large difference near the tank bottom, which results from the more realistic boundary condition adopted in the present model. Some representative results by the approximate solution including effects of the Peclet number on temperature distrbutions are illustrated to show the utility of this study. In consequence, it is expected that the present results based on the improved model replace the foregoing ones as a new theoretical reference for studies of thermal stratification fields.

  • PDF

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

LNG 연료탱크의 단열성능 평가 절차에 관한 연구 (A Study on Thermal Performance Evaluation Procedures of LNG Fuel Tank)

  • 조상훈;심명지;정영준;김익수
    • 한국가스학회지
    • /
    • 제22권3호
    • /
    • pp.45-52
    • /
    • 2018
  • 국제해사기구(IMO)의 선박 배출가스 기준 강화로 인해 LNG 연료추진선박의 필요성이 대두되고 있으며 관련 분야에 대한 기술개발 및 실용화 촉진 연구가 활발하게 진행되고 있다. LNG 연료탱크는 운항 중 연료소비로 인하여 잔류량이 70% 미만이 될 경우 슬로싱을 고려하여야 하므로 재액화 장치를 탑재하기 어려운 중소형 LNG 연료추진선박은 Type C 형태의 압력 탱크가 적용될 가능성이 높다. 이러한 LNG 연료추진선박에 적용되는 LNG 탱크는 구조적 안전성과 더불어 LNG를 오래 보관하기 위한 단열성능이 매우 중요하다. 본 연구에서는 Type C LNG Tank에 대한 단열성능 평가 절차를 제안하였고, 실험을 통해 LNG 탱크의 열적 특성으로 인한 온도, 압력, BOG(Boil Off Gas)의 변화를 비교, 분석함으로서 BOR(Boil Off Rate) 테스트 절차에 대한 타당성과 유효성을 검증하였다.

축열시스템의 온수이용 예측에 관한 연구 (The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System)

  • 조운;박이동
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

노심보충수탱크의 직접접촉응축에 대한 MARS의 계산능력평가 (ASSESSMENT OF MARS FOR DIRECT CONTACT CONDENSATION IN THE CORE MAKE-UP TANK)

  • 박근태;박익규;이승욱;박현식
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.64-72
    • /
    • 2014
  • This study aimed at assessing the analysis capability of thermal-hydraulic computer code, MARS for the behaviors of the core make-up tank (CMT). The sensitivity study on the nodalization to simulate the CMT was conducted, and the MARS calculations were compared with KAIST experimental data and RELAP5/MOD3.3 calculations. The 12-node model was fixed through a nodalization study to investigate the effect of the number of nodes in the CMT (2-, 4-, 8-, 12-, 16-node). The sensitivity studies on various parameters, such as water subcooling of the CMT, steam pressure, and natural circulation flow were done. MARS calculations were reasonable in the injection time and the effects of several parameters on the CMT behaviors even though the mesh-dependency should be properly treated for reactor applications.

멤브레인식 LNG 탱크벽체의 누설안전에 관한 수치해석적 연구 (Numerical Study on the Leakage Safety of the Membrane LNG Tank Wall)

  • 김청균;심종현
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.14-20
    • /
    • 2008
  • 본 논문에서는 멤브레인 내부탱크, 합판, PUF 보냉재, 또 다른 합판, 예응력 콘크리트(PC) 구조물로 건설된 LNG 저장탱크의 강도안전성을 4가지의 누설해석 파괴모델에 대해 수치적으로 해석하였다. $200,000\;m^3$의 저장용량을 갖는 탱크벽면을 통한 LNG의 누설기준은 열저항 온도해석의 핵심이론이다. 결국 누설 LNG의 초저온 온도가 외부탱크의 외측벽면에서 검출되면, 이것은 저장탱크의 벽면두께를 통해 누설되었다고 가정할 수 있다. 열저항법에 기초한 누설안전성 해석결과에 의하면 합판이나 PUF 등은 벽면을 통해 누설하는 LNG를 차단할 수 있지만, 이들 벽면은 누설 LNG의 압력에 의해 파괴되므로 누설안전성을 보장하지 못한다. 그러나, PC 외부탱크는 누설된 LNG 압력을 접해도 초기에는 견디지만, 시간이 경과하면서 누설된 LNG가 탱크벽체 내부로 계속 스며들어 벽체의 온도가 급격하게 떨어지면서 누설은 진행될 것으로 예상된다. 따라서 PC 외부탱크는 누설 LNG를 일정기간 체류시켜 LNG의 누설기간을 연장하는 효과를 제공할 뿐이다.

  • PDF