• 제목/요약/키워드: thermal power estimation

검색결과 108건 처리시간 0.028초

삼중압 열회수 증기발생기와 중기터빈 시스템의 열설계 해석 (Thermal Design Analysis of Triple-Pressure Heat Recovery Steam Generator and Steam Turbine Systems)

  • 김동섭;이봉렬;노승탁;신흥태;전용준
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.507-514
    • /
    • 2002
  • A computation routine, capable of performing thermal design analysis of the triple-pressure bottoming system (heat recovery steam generator and steam turbine) of combined cycle power plants, is developed. It is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. It can be applied to various parametric analyses including optimized design calculation. This paper presents analysis results for the effects on the design performance of heat exchanger arrangements at intermediate and high temperature parts as well as steam pressures. Also examined is the effect of steam sources for deaeration on design performance.

Study on Validity of 1-D Spherical Model on Aqua-plasma Power Estimation With Electrode Structure

  • 윤성영;장윤창;김곤호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.74-74
    • /
    • 2010
  • The aqua-plasma is the non-thermal plasma in electrical conductive electrolyte by generates the vapor film layer on the immersed metal electrode surface. This plasma can generate the hydroxyl radical by dissociate the water molecule with the plasma electron. To develop the plasma discharge device for high efficiency in the hydroxyl radical generation, proper model for estimation of plasma power is necessary. In this work, the 1-D spherical model was developed, considering temperature dependence material constants. The relation between the plasma power and hydroxyl generation was also studied by the comparison between the optical emission intensity from the hydroxyl radical using monochromator and estimated plasma power. First, the thickness of vapor layer thickness was estimated using the Navier-Stokes fluid equation in order to calculate the discharge E-field inside vapor layer. Using the E-field magnitude and power balance on the plasma generation, it was possible to estimate the plasma power. The plasma power was assumed to uniformly fill the vapor layer and the temperature of vapor layer was fixed in the boiling temperature of electrolyte, 375K. In the experiment, the aqua-plasma was discharged in the saline by applied the voltage on the bipolar electrode. The range of applied voltage was 234 to 280V-rms in the frequency of 380 kHz. Two type electrodes were produced with two ${\Phi}0.2$ tungsten. The plasma power was estimated from the V-I signal from the two high voltage probes and current probe. The estimated plasma power agreed with the profile of emission intensity when the plasma discharged between the metal electrode and vapor layer surface. However, when the plasma discharged between the metal electrodes, the increasing rate of emission intensity was lower than the increase of plasma power. It implies that the surface reaction is more sufficient rather than the volume reaction in the radical generation, due to the high density of water molecule in the liquid.

  • PDF

에너지함수법을 이용한 가용송전용량(ATC) 계산에 관한 연구 (A study on the ATC(Available Transfer Capabilily) calculation using an Energy Function Method)

  • 김재현;정성원;김양일
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.94-100
    • /
    • 2008
  • 가용송전용량(ATC)은 계통내의 한 지역에서 다른 지역까지 실제 전력을 증가시키는 것이다. 지금까지 ATC 계산은 대부분 정상상태에서 실행가능성을 주로 고려하여 계산되어 왔다. 하지만 ATC 평가시 과도안정도로 제약된 ATC 계산은 매우 중요한 부분이다. ATC 평가시에는 제약조건으로 열적용량, 전압 및 과도안정도로 제약된 상정사고(n-1)시 안전도 평가가 요구된다. 본 논문은 자코비안 행렬의 고유치를 이용하여 상정사고 우선순위를 선정하였고, 에너지 함수법을 이용하여 선로의 열적용량, 전압안정도 및 과도안정도를 고려한 ATC를 계산하였다.

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF

가공송전선로의 AAR 적용 시 Risk Tolerance 분석을 이용한 계절별 최대 허용전류 산정 및 적용에 관한 연구 (Study on the Estimation of Seasonal Ambient Current for the Application of Ambient Adjusted Line Rating(AAR) in Overhead Transmission Lines Using Risk Tolerance(RT) Method)

  • 이재걸;배영재;송지영;신정훈;김용학;김태균;윤용범
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.7-15
    • /
    • 2017
  • Ambient Adjusted line Rating(AAR) method for overhead transmission lines considering Risk Tolerance(RT) was proposed in this paper. AAR is suitable for system operators to plan their operation strategy and maintenance schedule because this can be designed as a seasonal line rating. Several candidate transmission lines are chosen to apply the proposed method in the paper. As a result, it is shown that system reliability was significantly enhanced through maximizing transfer capability, solving the system constraints.

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

CNN 기반 열 분포 영상을 이용한 배터리 SOC 추정 연구 (CNN based battery SOC estimation using thermal distribution image)

  • 권상욱;김재호;김용순;안정호;최어진;박진우;김종훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.453-454
    • /
    • 2019
  • 본 논문은 ESS(Energy Storage System)의 과충전, 과방전으로 인한 열 폭주 현상을 방지하기 위한 사전 연구로 원통형 리튬이온 단일 셀의 충/방전에 따른 열 분포를 열화상 카메라로 촬영하여 분석하였다. 실험을 통한 열 분포 이미지를 학습 데이터로 구성하여, SOC(State of Charge)를 추정하는 CNN(Convolution Neural Network) 모델을 제안한다.

  • PDF

Stream flow estimation in small to large size streams using Sentinel-1 Synthetic Aperture Radar (SAR) data in Han River Basin, Korea

  • Ahmad, Waqas;Kim, Dongkyun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.152-152
    • /
    • 2019
  • This study demonstrates a novel approach of remotely sensed estimates of stream flow at fifteen hydrological station in the Han River Basin, Korea. Multi-temporal data of the European Space Agency's Sentinel-1 SAR satellite from 19 January, 2015 to 25 August, 2018 is used to develop and validate the flow estimation model for each station. The flow estimation model is based on a power law relationship established between the remotely sensed surface area of water at a selected reach of the stream and the observed discharge. The satellite images were pre-processed for thermal noise, radiometric, speckle and terrain correction. The difference in SAR image brightness caused by the differences in SAR satellite look angle and atmospheric condition are corrected using the histogram matching technique. Selective area filtering is applied to identify the extent of the selected stream reach where the change in water surface area is highly sensitive to the change in stream discharge. Following this, an iterative procedure called the Optimum Threshold Classification Algorithm (OTC) is applied to the multi-temporal selective areas to extract a series of water surface areas. It is observed that the extracted water surface area and the stream discharge are related by the power law equation. A strong correlation coefficient ranging from 0.68 to 0.98 (mean=0.89) was observed for thirteen hydrological stations, while at two stations the relationship was highly affected by the hydraulic structures such as dam. It is further identified that the availability of remotely sensed data for a range of discharge conditions and the geometric properties of the selected stream reach such as the stream width and side slope influence the accuracy of the flow estimation model.

  • PDF

다목적 실용위성의 추진시스템 개발 (Development of Propulsion Subsystem for KOMPSAST)

  • 최진철;윤효철
    • 한국추진공학회지
    • /
    • 제2권3호
    • /
    • pp.80-89
    • /
    • 1998
  • 다목적 실용위성의 궤도전이 및 위성체 자세제어를 위한 추진시스템의 설계요소에는 구조적 안전성, 우주환경에서의 열 제어를 위한 회로 및 구성하드웨어 설계, 연료계통 맥압강하를 위한 장치설계 및 추력기 배기가스 영향을 고려한 형상설계 등이 있으며, 설계검증을 위해 부분해석이 수행된다. 또한 발사환경과 우주 궤도환경에서의 추진시스템 성능평가를 위한 열 제어계 기능시험, 압력인증시험, 청정도시험 및 내부/외부 누설시험이 수행된다. 본 논문에서는 추진시스템 설계 및 조립공정에 대해 기술하였고, 시험분석을 통해 시스템의 설계 및 조립공정상의 신뢰성을 검증 분석하였다.

  • PDF