• Title/Summary/Keyword: thermal difference

Search Result 2,315, Processing Time 0.028 seconds

Thermal Mixing in a Microchannel (마이크로 채널에서의 열혼합 특성)

  • Park, Kyoung-Bae;Ahn, Joon;Kim, Byoung-Joon;Lee, Joon-Sik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.585-588
    • /
    • 2008
  • Thermal mixing phenomena in a Y-type microchannel were investigated using a micro-PIV. Two inlet reservoirs of the microchannel were controlled individually so that the characteristics of thermal mixing in the channel with temperature difference were compared with those without the difference. The velocity field in the mixing process was measured using the micro-PIV system that includes an ICCD (Intensified CCD) camera. The mixing area and uniformity were also analyzed. It is observed that the flow fluctuation in spanwise direction is induced by temperature difference, which enhances mixing process in microchannels.

  • PDF

Diagnostic of Cast Resin Using Active Infrared Thermal Testing Method (능동열시험법을 이용한 몰드변압기 진단)

  • Lim, Young-Bae;Jeong, Seung-Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.481-484
    • /
    • 2004
  • A form of measured temperature distribution to estimate condition of a electrical apparatus is a absolute reference for condition of the apparatus, time rate of transition, and difference between reference and currently temperature. Because passive thermography which has not injection of external thermal stimulation shows difference of temperature being on surface of a structure and temperature difference between the structure and back ground, the result could apply only to estimation or monitor for condition of terminal relaxation and overload related with temperature rising. However, a thermal flow in active thermography is differently generated by structure and condition of surface and subsurface. This paper presents the nondestructive testing using the properties and includes the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

A Study on Thermal Comfortable Following the Thermal Environment Migration in Detached Housing Area (열환경 완화를 통한 주택지내 쾌적성 확보에 관한 연구)

  • Ryu, Ji-Won;Jung, Eung-Ho;Hoyano, Akira;Kim, Dae-Wuk
    • Journal of the Korean housing association
    • /
    • v.24 no.1
    • /
    • pp.51-59
    • /
    • 2013
  • This study aims to improve the thermal comfort level of detached housing area by reducing the impact of thermal environment. The study focused on reducing surface temperature that is generated in buildings and adjacent spaces as a result of sensible heat load and presented a proposal on implementing planting method considering its outdoor condition and structure and composed materials. To perform the study, we utilized 3D-CAD to examine the outdoor condition and structure and composed materials that impact on surface temperature and conducted space design after reflecting climatic elements in simulations. The result is as follows. In reviewing temperature distribution of Heat Island Potential (HIP) of buildings and adjacent spaces, in case where green coverage ratio is increased, there was a $6^{\circ}C$ temperature difference and in regard to changes in the thermal environment in detached housing area, in case where rooftop planting, surface improvement, planting, and overall green coverage ratio is increased, there was a $10^{\circ}C$ temperature difference. In addition, there was difference in temperature in detached housing area following the changes in wind.

Energy Consumption Characteristics and Evaluation of Thermal Insulation Performance in Accordance with Built Year of Apartment Complex (공동주택의 준공연도에 따른 단열성능 평가 및 에너지소비 특성에 관한 연구)

  • Choi, Doo Sung;Lee, Myung Eun;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.79-86
    • /
    • 2014
  • Studies have shown that the thermal performance of buildings changes depending on the year of construction completion. It leads to increased energy consumption of buildings and significant financial burden on users. Thus, this study has calculated the thermal insulation performance of 86 apartments quantitatively, using temperature difference ratio and sensible heat flux. Also, energy consumption characteristics depending on the year of construction completion and thermal insulation performance were analyzed by comparatively analyzing the results of insulation performance evaluation and heating costs. The analysis results are as follows. As for thermal insulation performance, it was around 70% lower in the apartments completed before 1985, compared to apartments completed after 2010. As for heating costs, the apartments with the highest heating cost incurred 1.5 higher heating cost than the apartment with the lowest heating cost. In terms of the insulation performance evaluation, the difference was 2.5-fold.

A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics (바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

Evaluation of Thermal Comfort on Temperature Differences between Outdoor and Indoor Thermal Conditions in Summer (여름철 실내외 온도차에 따른 인체의 온열쾌적성 평가)

  • 금종수;김동규;최광환;이낙범;임재중;최호선;배동석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.890-896
    • /
    • 2002
  • Purpose of this study is to clarify the evaluation of thermal comfort based on temperature differences between outdoor and indoor thermal conditions in summer. The experiments were performed to evaluate temperature difference between indoor and outdoor thermal conditions (29, 31, $33^{\circ}$) by physiological and psychological responses of human. According to physiological responses, TSV (thermal sensation vote) and CSV (comfort sensation vote) and psychological responses, ECG (electrocardiogram), MST (mean skin temperature) of human, it was clear that the optimum temperature difference is about $5^{\circ})\;and\;7^{\circ}$).

Thermal buckling of FGM beams having parabolic thickness variation and temperature dependent materials

  • Arioui, Othman;Belakhdar, Khalil;Kaci, Abdelhakim;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.777-788
    • /
    • 2018
  • An investigation on the thermal buckling resistance of simply supported FGM beams having parabolic-concave thickness variation and temperature dependent material properties is presented in this paper. An analytical formulation based on the first order beam theory is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. a function of thickness variation is introduced which controls the parabolic variation intensity of the beam thickness without changing its original material volume. The results showed the high importance of taking into account the temperature-dependent material properties in the thermal buckling analysis of such critical beam sections. Different Influencing parametric on the thermal stability are studied which may help in design guidelines of such complex structures.