Reaction Kinetic Study on Pyrolysis of Waste Polystyrene using Wetted Column Reactor (Wetted Column 반응기를 이용한 폴리스티렌 열분해 반응속도론적 연구)

  • You, Young Gil;Yoon, Byung Tae;Kim, Seong Bo;Choi, Myoung Jae;Choi, Cheong Song
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.535-539
    • /
    • 2008
  • Conversion to oil, yield of styrene and formation of side products such as ${\alpha}-methyl$ styrene, ethyl benzene, benzene, toluene, dimer and trimer were affected by residue formed during thermal degradation. Also, control of reaction temperature had a difficulty at the first stage. Thus, new reaction system using wetted-wall type reactor was proposed and examined on various parameters such as reaction temperature, feeding rate and removal velocity of formed vapor. Optimun condition was obtained from continuous thermal degradation using wetted-wall type reactor and reaction kinetic study was carried out at new type reactor.

Effect of Organic Residue on the Continuous Pyrolysis of Waste Polystyrene (연속식 폐 EPS 열분해 반응에 대한 잔류물의 영향)

  • Yoon, Byung Tae;Kim, Seong Bo;Lee, Sang Bong;Choi, Myoung Jae
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.125-128
    • /
    • 2005
  • Oil formation rate, composition of crude oil and formation of side products such as ${\alpha}-methyl$ styrene, ethyl benzene, benzene, toluene, dimer and trimer on thermal degradation of polystyrene were affected by various factors. Especially, formation of organic residue formed during reaction gave an important influence on formation of oil and composition of crude oil. Also, composition of formed crude oil showed a significant difference on reaction time. These results were caused by organic residue and carbonized solid formed during continuous reaction. Increase of residue and carbonized solid gave a decrease of yield of styrene and an increase of formation of ${\alpha}-methyl$ styrene, ethyl benzene, benzene, toluene. New reaction system was proposed for continuous operation at the thermal degradation of polystyrene.

The Continuous Pyrolysis of Waste Polystyrene using Wetted-Wall Type Reactor (Wetted-Wall Column 형 반응기를 이용한 폐 EPS 연속 열분해반응)

  • Han, Myung Sook;Han, Myung Wan;Yoon, Byung Tae;Kim, Seong Bo;Choi, Myoung Jae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.396-399
    • /
    • 2007
  • Organic residue and carbonized solid producing from the thermal degradation gave a influence on oil conversion, formation of styrene and side products such as ${\alpha}-methyl$ styrene, ethyl benzene, dimer. Thus, new reaction system using wetted-wall type reactor was proposed and examined on influence of various parameters such as reaction temperature, feeding rate and removal velocity of formed vapor. Optimum condition were obtained from continuous thermal degradation using wetted-wall type reactor and styrene was continuously obtained as the yield up 65%.

Kinetic Studies on the Thermal Degradation of Ginsenosides in Ginseng Extract (Ginsenosides의 처리온도(處理溫度) 및 시간(時閭)에 따른 반응속도론적(反應速度論的) 연구(硏究))

  • Choi, Jin-Ho;Kim, Doo-Ha;Sung, Hyun-Soon;Kim, Woo-Jung;Oh, Sung-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.197-202
    • /
    • 1982
  • Kinetic study for the thermal degradation of ginsenosides in ginseng extract was conducted. The results indicate that the thermal degradation followed first order kinetics and rate constants varied substantially depending on the types of ginsenosides and heat treatment temperatures. Activation energy calculated by Arrhenius plots ranged from 16.80 kcal/mole to 30.10 kcal/mole and $Q_{10}$ values ranged from 2.01 to 3.49. Correlation coefficients between the change of ginsenoside contents by thermal degradation and heat treatment temperature were $0.995{\sim}0.999$. The dependence on temperatures of the decomposition rate constant of total ginsenoside can be expressed as $k=4.574{\times}10^8$ exp(8898.8/T).

  • PDF

Prospects on the Use of Corrosion Rate Measurement Method for Stainless Steel (스테인리스 강의 부식 측정방법의 이용과 전망)

  • Choi, Yongseon;Lee, Jaewon;Park, Eunoak;Lee, Kiyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.294-301
    • /
    • 2021
  • As the number of cases of performance degradation owing to corrosion of plant during processing in industries increases, the cost of maintaining industrial factory is increasing year by the year. Most of the materials of the facilities are consist of stainless steel (SS) such as austenite SS, ferrite SS, martensite SS, and duplex SS. Among them austenite SS is cheap and has excellent corrosion resistance and heat resistance. Corrosion is the consumption and change of metals by altering chemical and electrical reactions. The types of SS corrosion include pitting corrosion, crevice corrosion, galvanic corrosion, stress corrosion cracking, and thermal corrosion. The corrosion of SS is not only investigated various environmental factors but also the measurement of the corrosion rate. Therefore, it aims to understand comprehensive corrosion rates in various environments using qualitative, quantitative and electrochemical methods.

Assessment of Creep Damage on a High Temperature Pipe Bend of 0.5Cr0.5Mo0.25V Ferritic Steel for Thermal Power Plant (화력발전소용 0.5Cr 0.5Mo 0.25V 강 곡관배관의 크리프 손상평가)

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Bong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.127-134
    • /
    • 2010
  • Components in thermal power plants are subjected to service conditions under which creep damages take place causing material exhaustion. Comprehensive creep damage investigations have been performed on a 0.5Cr0.5Mo0.25V pipe bend which had been taken out of service after 117,603h and 501 start-ups because of severe cracks. The propagation of creep damage in a long term exposed pipe bend has been analysed by the replication, Indentation and hardness tests. Also, Calculation of creep lifetime has been investigated in order to verify actual lifetime of a damaged pipe bend. By measuring diametrical expansion, Accumulated creep strain and creep strain rate were calculated. Calculated results of creep lifetime on the Larson-Miller Parameter method are good agreement with actual service-exposed hour.

Thermal Curing and Electrical Properties of Epoxy/Graphite/Expanded Graphite Composite for Bipolar Plate of Pemfc (PEMFC 바이폴라 플레이트 제조용 EPOXY/GRAPHITE/EXPANDED GRAPHITE 복합재료의 열경화 및 전기적 성질)

  • Lee, Jae-Young;Lee, Hong-Ki
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.6
    • /
    • pp.827-834
    • /
    • 2011
  • Epoxy/graphite/expanded graphite composites have been prepared in various weight ratios and thermal degradation and electrical properties were estimated in order to use for the bipolar plate materials in PEMFC. Thermogravimetric analysis (TGA) showed that the epoxy/graphite system cured by a curing agent GX-533 was most proper because its weight loss until $80^{\circ}C$ at which PEMFC would be operated was 0.3 wt%, and differential scanning calorimetry (DSC) analysis showed its cure temperature would be sufficient at $80^{\circ}C$. The activation energy for the cure reaction was 132.0 kJ/mol and the pre-exponential factor was $1.76{\times}10^{17}min^{-1}$. Electrical conductivity on the surface of the bipolar plate prepared under a pressure of 200 $kgf/cm^2$ was increased from 4 to 25 $S/cm^2$ by increasing expanded graphite (EG) content from 50 phr to 90 phr. The percolation threshold was initiated around 75 phr and the corrosion rate at 80 phr was 1.903 $uA/cm^2$.

Alternative Selection Method for Energy Efficiency Improvement of Old Detached House (노후 단독주택의 난방에너지 효율 개선을 위한 대안 선정 방법에 관한 연구)

  • Hwang, Seok-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.45-55
    • /
    • 2019
  • More than 76% of the detached houses in Korea are over 20 years old. These old detached houses have poor energy efficiency. According to the 2017 Housing Census (Statistics Korea), more than 50% of low-income families live in detached houses. Therefore, the improvement of energy efficiency in old detached houses is needed from the viewpoint of energy welfare. The general method of building energy modelling for the verification of energy efficiency is based on the construction year data of "Building Design Criteria for Energy Saving" due to the cost and time involved in collecting the thermal performance data of buildings. There is poor accuracy with the deterioration of long-term aging of building materials. Also, the selection of alternatives for energy performance improvement is based on the items to be applied, not a performance improvement goal. It is difficult to calculate energy performance that reflects variations in various parameters with dynamic energy simulations. In this study, the influence of long-term aging is used to accurately predict the energy performance of old detached houses. The building energy modelling method is called ENERGY#, which is a static analysis method based on ISO13790. Energy performance is evaluated by a combination of input variables including building orientation, insulation of walls and roof, thermal performance of windows and window/wall ratio, and infiltration rate. Finally, this study provides a way to determine alternatives that meet energy performance improvement goals.

Analysis on the Reduction of Cooling Load and Improvement of Visual Environment by applying a Kinetic Shading Device in Summer (가변형 차양장치 적용에 따른 하절기 냉방부하 저감 및 빛환경 개선효과 분석)

  • Cha, Gi-Wook;Moon, Hyeun Jun;Kim, Ho-Jeong;Hong, Won-Hwa;Baik, Yong-Kyu
    • Journal of Korean Living Environment System
    • /
    • v.24 no.6
    • /
    • pp.810-823
    • /
    • 2017
  • The envelope is important for sustainable building. Recent commercial buildings are causing thermal degradation and cooling load due to the increase of the area of the windows. Therefore, this research studied kinetic shading system which can improve energy saving and visual environment in summer. For that, this study proposed new shading system and shape considering the orientation of the building and the location of the sun. Based on this, this study analyzed the effectiveness on energy reduction and improvement of visual environment by applying the kinetic shading system proposed in this study. As the results of this study, energy reduction rate was 35% in the east, 22.9% in the south, and 30.7% in the west depending on the application location. Also, as the result of the illuminance analysis, it was found that the effect of achieving uniformity ratio of illumination was considerable.

Color and Chlorophyll of Blanched Vegetable Soybean by NaCl (열처리 시 소금첨가에 의한 풋콩의 색과 Chlorophyll 함량 변화)

  • Song, Jae-Yeun;Kim, Chul-Jai;An, Gil-Hwan
    • Korean Journal of Agricultural Science
    • /
    • v.30 no.2
    • /
    • pp.148-153
    • /
    • 2003
  • Vegetable soybeans were blanched at 80, 90 and $100^{\circ}C$ for 30, 20 and 10min, respectively. NaCl(3%) was also used to measure the protective effect of soybean color. The color of vegetable soybeans was measured by colorimeter, -a value (greenness) was highest at $100^{\circ}C$-10min. However, the chlorophyll contents was highest at $80^{\circ}C$-30min. NaCl (3%) decreased the loss of chlorophyll in blanched vegetable soybeans. The reaction rate constant for the thermal degradation of chlorophyll and greenness doubled per $10^{\circ}C$. The activation energy chlorophyll a of pod for thermal degradation of chlorophyll a in pods were 138.02 (unsalted), 146.63 (salted) Kcal/mol, respectively.

  • PDF