• 제목/요약/키워드: thermal curtain

검색결과 104건 처리시간 0.022초

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

스틸 커튼월의 단열성능 및 결로방지성능 평가 (Evaluation of the Thermal Performance and Condensation Resistance of a Steel Frame Curtain Wall System)

  • 김선숙;조봉호
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.51-57
    • /
    • 2013
  • Metal curtain wall systems are widely used in high-rise commercial and residential buildings. While aluminum is the most frequent used frame material, steel framing is also reemerging as a high-performance material in glazed curtain walls due to less thermal conductivity and design flexibility. The purpose of this study is to evaluate thermal performance of a steel frame curtain wall system by comparing with a aluminum frame curtain wall system. The thermal transmittance was measured according to KS 2278, and condensation resistance was calculated by the test results according to KS F 2295. The steel framing test specimen showed lower thermal transmittance and temperature descending factor compared to the aluminum framing test specimen.

야간(夜間)의 온실내(溫室內) 보온(保溫)커텐의 보온효과분석(保溫效果分析) (Analysis of Nocturnal Thermal Insulation Effect of Thermal Curtain in Plastic Greenhouse)

  • 조용백;고학균;김문기;김용현
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.22-29
    • /
    • 1989
  • A simulation model of plastic greenhouse was developed to evaluate the insulation effect of thermal curtain. Change in thermal environment with and without thermal curtain was verified through experiments, which agreed with the predicted values satisfactorily. About 18 to 20% of energy was saved in the plastic greenhouse by employing the P.E. film thermal curtain. Employing P.E. film thermal curtain also raised the temperature of the covering film and inner air by $1^{\circ}C$ and $1.5{\sim}1.8^{\circ}C$, respectively.

  • PDF

박스형 이중외피와 커튼월 창호의 난방기 열적성능 비교 (A Study on thermal performance of box type double skin facade and curtain wall in heating period)

  • 박창영;최창호;이건호;윤용상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.909-914
    • /
    • 2006
  • The purpose of this study is to analyze the thermal of DFS(double Facade System) and curtain wall in the heating period. The physical difference between curtain wall and double facade on thermal performance has been tested at the newly constructed laboratory, which can turn $360^{\circ}$ to confirm the characteristic of a facade with the various directions. This study divide on 'ventilated, airtight' and 'heated or unheated' conditions from the CASE 1, 2, 3, 4. The results showed thermal performance of double facade system which has been better than curtain wall. The heating energy of DFS reduced $8%{\sim}10%$ of energy consumption. comparable to SFS in experemted results. In view of the researching results so far achieved, the research came to a conclusion, that the curtain wall can save the energy in the heating period than a curtain wall.

  • PDF

열교부위를 고려한 커튼월 사무소 건물의 열성능 해석에 관한 연구 (A Study on the Thermal Performance Analysis of Curtain Wall Office Building Considering the Thermal Bridges)

  • 신우철;김승철;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Currently, office buildings in Korea tend to adopt as their outer wall the curtain wall structure which can be easily constructed and has beautiful external appearance as well. However, the problem is that the curtain wall structure does not have a uniform composition unlike the wall of existing reinforced concrete structures and has a frame made of metal with high heat conduction. Therefore, it is expected that the structure will be highly influenced by the thermal bridge. Thereupon, this study analyzes how to set up the composition of the wall system and heat transmission rate in consideration of the thermal characteristics of the curtain wall structure and applies it in practice by simulation in order to propose a guideline for the energy simulation method of the curtain wall structure and analyze its differences from existing simulation methods.

Relationship of the U-Factor and Chemical Structure with Applied Metal and Polymer Material Assembly in Curtain Wall Frame

  • Park, Tongso
    • 한국재료학회지
    • /
    • 제31권8호
    • /
    • pp.450-457
    • /
    • 2021
  • From measured thermal conductivity and modeling by simulation, this study suggests that U-factors are highly related to materials used between steel and polymer. The objective and prospective point of this study are to relate the relationship between the U-factor and the thermal conductivity of the materials used. For the characterization, EDX, SEM, a thermal conductive meter, and computer simulation utility are used to analyze the elemental, surface structural properties, and U-factor with a simulation of the used material between steel and polymer. This study set out to divide the curtain wall system that makes up the envelope into an aluminum frame section and entrance frame section and interpret their thermal performance with U-factors. Based on the U-factor thermal analysis results, the target curtain wall system is divided into fix and vent types. The glass is 24 mm double glazing (6 mm common glass +12 mm Argon +6 mm Low E). The same U-factor of 1.45 W/m2·K is applied. The interpretation results show that the U-factor and total U-value of the aluminum frame section are 1.449 and 2.343 W/m2·K, respectively. Meanwhile, those of the entrance frame section are 1.449 and 2.

커튼월 유리의 열파손에 관한 실험적 연구 (An Experimental Study on Thermal Breakage in Curtain Wall Glazing)

  • 이재현;남중우;방중석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.236-237
    • /
    • 2013
  • In recent years, the use of glass applied to curtain wall as a building facade material has increased in our nation. However, the non-tempered curved double glass is very easy to broke because it is difficult to guarantee the quality in process of making it into double glazing. So, it is more vulnerable to thermal breakage than tempered double glass. In this paper, surface temperature difference on curved double glazing was compared to that of heat strengthened glass and flat glass by conducting thermal breakage experiments. As a result, flat single glass was broken at temperature difference of 100~140 degrees but curved double glazing was broken at that of 40~60 degrees. Therefore, it was concluded that curved double glazing is more vulnerable than flat double glazing to thermal breakage, and it should be considered the possibility of thermal breakage when curtain wall glazing is applied as a building facade material.

  • PDF

초고층 커튼월 외피 열성능해석 프로그램 개발에 관한 연구 (A Study on the Development of High-rise Curtain Wall Thermal Analysis Program)

  • 노상태;김강수;정진세
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.10-18
    • /
    • 2007
  • The purpose of this study is to develop an user-friendly computer program which can analyze the thermal performance of high-rise curtain wall. In this study, the sub-routines for FVM SOLVER, HIGH-RISE CONDITION CALCULATION, AUTOMATIC SPECIFICATION BOUNDARY/MESH, MATERIAL DATABASE, and GRAPHICAL CONDENSATION/U-FACTOR OUTPUT were developed by using Visual Basic. The curtain wall heat conduction simulation results of program showed good agreement with those of FLUENT and THERM. The minimum and maximum relative error rates were 3.17 and 9.68% compared to other software.

적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가 (Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis)

  • 문종필;윤남규;이성현;김학주;이수장;김영화
    • 한국농공학회논문집
    • /
    • 제52권2호
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

Green Curtain 형식의 벽면녹화시스템을 통한 여름철 건물 실내 열환경 비교 분석 (Analysis of Thermal Environment Improving Effects of Green Curtain in Summer)

  • 이선영;조상만;박수국
    • 한국조경학회지
    • /
    • 제50권5호
    • /
    • pp.80-89
    • /
    • 2022
  • 본 연구는 수평적인 열환경 개선의 한계점을 해결하기 위해, 수직적인 녹화방법인 green curtain을 이용한 건물의 벽면녹화 유무에 따른 여름철 건물 실내와 실외의 열환경을 비교하였다. 측정은 2021년 여름철 건물내부 중심부 지점과 건물 외부 잔디밭 지점을 대상으로 미기후 자료인 기온, 상대습도, 풍속, 태양 및 지구복사에너지를 측정하여 인간 열환경지수인 PET와 UTCI를 계산하여 비교 분석하였다. 그 결과, 주간 기온은 평균 1.6℃ 더 시원한 결과를 보였으며, 야간에는 green curtain의 효과가 나타나지 않았다. 상대습도는 주간에 평균 5.6%, 야간에 평균 1.0% 실내가 더 높은 결과를 보였다. 풍속은 주간에 평균 1.4-1.8ms-1, 야간에 평균 1.4-1.5ms-1로 green curtain의 설치 여부와 관계없이 실외에서 높은 값을 보였다. 평균복사온도는 평균 4.7℃ 감소 효과를 보여주었으며, 야간에는 green curtain의 효과가 나타나지 않았다. 인간 열환경지수인 PET와 UTCI 결과에서는 주간 PET는 평균 2.1℃의 저감 효과를 보여 1/3 단계의 실내 열지각 개선 효과를 나타내었으며, UTCI는 평균 1.1℃로 1/6 단계의 열스트레스 저감 효과를 보이는 것으로 나타났고, 야간에는 PET와 UTCI 모두 green curtain의 효과가 나타나지 않았다. 조경계획 시 여름철 주간시간대의 열환경 개선을 위한 방안으로 green curtain을 활용하는 것도 효과적일 것이다.