• Title/Summary/Keyword: thermal change

Search Result 3,160, Processing Time 0.025 seconds

Strip Tension Control Considering the Temperature Change in Multi-Span Systems

  • Lee Chang Woo;Shin Kee Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.958-967
    • /
    • 2005
  • The mathematical model for tension behaviors of a moving web by Shin (2000) is extended to the tension model considering the thermal strain due to temperature variation in furnace. The extended model includes the terms that take into account the effect of the change of the Young's Modulus, the thermal coefficient, and the thermal strain on the variation of strip tension. Computer simulation study proved that the extended tension model could be used to analyze tension behaviors even when the strip goes through temperature variation. By using the extended tension model, a new tension control method is suggested in this paper. The key factors of suggested tension control method include that the thermal strain of strip could be compensated by using the velocity adjustment of the helper-rollers. The computer simulation was carried out to confirm the performance of the suggested tension control method. Simulation results show that the suggested tension control logic not only overcomes the problem of the traditional tension control logic, but also improves the performance of tension control in a furnace of the CAL (Continuous Annealing Line).

Change of thermal environment in buildings by wind direction (풍향에 따른 건물군에서의 열환경 변화)

  • Kim, Sang-Jin
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.27-32
    • /
    • 2012
  • In recent years, the quality of the outdoor thermal environment has come to be regarded as important as that of the indoor thermal environment. Since the outdoor thermal environment is composed of many elements and is affected by many factors, it is not easy to evaluate the impact of each factor separately. Hence, a comprehensive assessment method is required. In order to evaluate the pedestrian level comfort of an outdoor climate, it is necessary to investigate not only wind velocity but also various physical elements, such as temperature, moisture, radiation, etc. Prediction of wind and thermal environment for a large scale buildings is one of the most important targets for research. Wind and thermal change in a city area is a very complicated phenomenon affected by many physical processes. The purpose of this study is to develop a design plan for wind environment at a large Buildings. In this study, we analyze outdoor wind environment and thermal environment on buildings using the CFD (Computational Fluid Dynamics) method. The arrangement of building models is an apartment in Jeonju. These prediction of wind and thermal environment for a large scale buildings is necessary in a plan before a building is built.

Study on cooling performance and isothermal maintenance of cylindrical type lithium-ion battery cell using phase change material (상변화물질을 활용한 원통형 리튬이온 배터리 셀의 냉각성능 및 등온유지성에 관한 연구)

  • Jae Hyung Yoon;Su Woong Hyun;Hee Jun Jeong;Dong Ho Shin
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2023
  • When lithium-ion batteries operate out of the proper temperature range, their performance can be significantly degraded and safety issues such as thermal runaway can occur. Therefore, battery thermal management systems are widely researched to maintain the temperature of Li-ion battery cells within the proper temperature range during the charging and discharging process. This study investigates the cooling performance and isothermal maintenance of cooling materials by measuring the surface temperature of a battery cell with or without cooling materials, such as silicone oil, thermal adhesive, and phase change materials during discharge process of battery by the experimental and numerical analysis. As a result of the experiment, the battery pack filled with phase change material showed a temperature reduction of 47.4 ℃ compared to the case of natural convection. It proves the advanced utility of the cooling unit using phase change material that is suitable for use in battery thermal management systems.

The characteristics of microencapsulated phase-change materials (상전이 마이크로캡슐 재료의 축열특성)

  • 임대우
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.53-56
    • /
    • 2003
  • The objective of this research is to investigate the thermal behavior of microencapsulated phase-change materials(MEPCM), and a shell of melamine-formaldehyde. These PCM materials were tested using DSC and thermal data station. Fabrics with enhanced thermal properties were prepared by padding the fabrics with the microcapsules containing PCM and acryl binder. The rate of temperature increase was significantly decreased as the amount of MEPCM added on the surface of the fabrics increased.

  • PDF

The Analysis for Thermal Comfort Evaluation during long time operating Air Conditioner (에어컨 장시간 운전시 온열쾌적감 평가에 관한 연구)

  • Kim, Dong-Gyu;Park, Jong-Il;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.59-64
    • /
    • 2007
  • Using air conditioner has been increased in home or office buildings in summer. Also various problems related to air conditioning such as disease induction happened by using air conditioner excessively and operating long. Active operation control is needed for occupant's health when air conditioner operates long. We should think ahead to acquire thermal comfort of occupants which represents psychological and physiological reaction for this operation. Research has been progressed to observe activity of autonomic nervous system by trying to quantitate change of thermal comfort. In this study, questions of the subject and change of body's autonomic nervous system were chosen to evaluate thermal comfort during operation of air conditioner for a long time. Electrocardiogram and questions of the subject which is the progress of changing TSV and CSV by occupants indoor were measured when room air conditioner is operated for a long time, and an air-conditioned adaptability of human body was evaluated by acquiring the change rate of autonomic nervous system through analyzing HRV. As a result of the evaluation, change rate of body's autonomic nervous system corresponded to votes of the subject's question generally, but was distinguished from analysis result of warm-cold sensation in a low temperature area.

Experimental Observations of Boiling and Flow Evolution in a Coiled Tube

  • Ye, P.;Peng, X.F.;Wu, H.L.;Meng, M.;Gong, Y. Eric
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2008
  • A sequence of visually experimental observations was conducted to investigate the flow boiling and two-phase flow in a coiled tube. Different boiling modes and bubble dynamical evolutions were identified for better recognizing the phenomena and understanding the two-phase flow evolution and heat transfer mechanisms. The dissolved gases and remained vapor would serve as foreign nucleation sites, and together with the effect of buoyancy, centrifugal force and liquid flow, these also induce very different flow boiling nucleation, boiling modes, bubble dynamical behavior, and further the boiling heat transfer performance. Bubbly flow, plug flow, slug flow, stratified/wavy flow and annular flow were observed during the boiling process in the coiled tube. Particularly the effects of flow reconstructing and thermal non-equilibrium release in the bends were noted and discussed with the physical understanding. Coupled with the effects of the buoyancy, centrifugal force and inertia or momentum ratio of the two fluids, the flow reconstructing and thermal non-equilibrium release effects have critical importance for flow pattern in the bends and flow evolution in next straight sections.

Satellite Thermal Control Device Enhanced by Latent Heat of the Phase Change Material (응고/융해 잠열을 이용한 위성용 열제어장치의 실험적 연구)

  • Kim, Tae Su;Shin, Yoon Sub;Kim, Taig Young;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.887-894
    • /
    • 2016
  • The thermal control device using solid-liquid phase change material (PCM) is designed, manufactured, and experimented in thermal environment chamber. The n-Hexadecane is selected as a PCM and its melting point is placed within the component working temperature range. The PCM container is made of Al6061 and has the thermal spreading fins inside. To simulate the working condition for on-orbit satellite the heat pipes are used to connect the heater and radiator and the PCM thermal control device (PCMTD) is installed at the middle portion of heat pipes. The thermal buffer mass (TBM), which is same configuration and volume with PCMTD, is also manufactured to compare the thermal control performance. As a result, the PCMTD is not only more efficient than TBM in their temperature control features but both mass and power of compensation heater are reduced.

Electrical and thermal characteristics of PRAM with thickness of phase change thin film (상변화 박막의 두께에 따른 상변화 메모리의 전류 및 열 특성)

  • Choi, Hong-Kyw;Kim, Hong-Seung;Lee, Seong-Hwan;Jang, Nak-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.162-168
    • /
    • 2008
  • In this paper, we analyzed the heat transfer phenomenon and the reset current variation of PRAM device with thickness of phase change material using the 3-D finite element analysis tool. From the simulation, Joule's heat was generated at the contact surface of phase change material and bottom electrode of PRAM. As the thickness of phase change material was decreased, the reset current was highly increased. In case thickness of phase change material thin film was $200\;{\AA}$, heat increased through top electrode and reset current caused by phase transition highly increased. And as thermal conductivity of top electrode decreased, temperature of unit memory cell was increased.

High School Exploration of a Phase Change Material as a Thermal Energy Storage

  • Ardnaree, Kwanhathai;Triampo, Darapond;Yodyingyong, Supan
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.2
    • /
    • pp.145-150
    • /
    • 2021
  • The present study describes a hands-on experiment to help students understand the concept of phase change or phase transition and its application in a phase change material (PCM). PCMs are substances that have the capability of storing and releasing large amounts of thermal energy. They act as energy storage materials that provide an effective way to save energy by reducing the electricity required for heating and cooling. Lauric acid (LA) was selected as an example of the PCM. Students investigated the temperature change of LA and the temperature (of air) inside the test tube. The differences in the temperatures of the systems helped students understand how PCMs work. A one-group pretest and posttest design was implemented with 34 grade-11 students in science and mathematics. Students' understanding was assessed using a multiple-choice test and a questionnaire. The findings revealed that the designed activity helped students understand the concept of phase change and its application to materials for thermal energy storage.

A Study on the Behavior of Brine Lumps Caused by Dropping Brine (염수투하에 따른 염수괴 거동에 관한 연구)

  • ;K. Nakatsuji
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.1
    • /
    • pp.21-28
    • /
    • 1991
  • this paper, two-dimensional behaviors of the brine lumps moving along the inclined boundaries are investigated experimentally and theoretically. It was investigated these factors in the brine lumps which are behaviors. shape. length change. height change. and moving velocity change. The results were compared the above factors with thermal theory. The shape of the brine lumps is well apporximated by a half-ellipse. The shape of the brine lumps was similar with the slope thermal and the moving characteristics were found to reappear with the turbulent thermal theory.

  • PDF