• 제목/요약/키워드: thermal capacity

검색결과 1,279건 처리시간 0.029초

천연 제올라이트의 물리화학적 성질 -경북 감포산 제올라이트에 관하여- (Physico-Chemical Properties of Natural Zeolite -On the Zeolite from Kampo Area-)

  • 조승래;이홍기;이주성;심미자;김상욱
    • 한국표면공학회지
    • /
    • 제26권6호
    • /
    • pp.334-340
    • /
    • 1993
  • The physico-chemical properties and characteristics after thermal treatment of natural zeolite from Kampo area were studied. The physico-chemical properties of natural zeolite were studied by investigating chemical composition, x-ray diffraction pattern(XRD), scanning electronic microscope(SEM), infrared spec-tra(IR), thermal analysis(TA), and cation exchange capacity(C.E.C.), and the characteristics of natural zeo-lite after thermal treatment from $400^{\circ}C$ to $900^{\circ}C$ were compared with the natural zeolite. This study showed that clinoptilolite was the predominant costituent in natural zeolite, and the natural zeolite contained a little amount of quartz and feldspar as impurities. Zeolite mineral was seen to develop slowly by the natural alternation of volcanic ash considering the almost amorphous crystal structure. The more temperature of ther-mal treatment increased, the more adsorption capacity decreased, considering the fact that the hydroxy peak diminished on infrared spectra, and that cation exchange capacity also decreased distinctly.

  • PDF

열펌프-잠열축열 시스템 온실에서 토양의 열저장 및 방열 특성 (Thermal Energy Storage and Release Characteristics of the Soil in the Greenhouse Equipped with Heat Pump and Latent Heat Storage System)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제27권1호
    • /
    • pp.39-44
    • /
    • 2002
  • In order to obtain the information of bio-environment control, the thermal characteristics of soil in the greenhouse heated by the heat pump and latent heat storage system were experimentally analyzed. The experimental systems were composed of the greenhouse with a heat pump and a latent heat storage system (system I), the greenhouse with a heat pump (system II), the greenhouse with a latent heat storage system (system III), and the greenhouse without auxiliary heating system (system IV). The thermal characteristics experimentally analyzed in each system were temperature of soil layers, soil heat storage and release, soil heat capacity and soil heat storage ratio. The results could be summarized as follows. 1. Time to reach the highest temperature at 20cm deep in soil layers of the crop routs in case of system I was shown to be delayed by 6 hours in comparison to the time of the highest temperature at the soil surface. 2. In the clear winter days, the stored heat capacity values fur the system I and the system II were shown to be 22.3% and 11.0% higher than the released heat capacity respectively, and the stored heat capacity values for the system III and the system IV were shown to be 6.2% and 29.6% lower than the released heat capacity respectively This confirms that the system I provided the best heat storage effect. j. The heat quantity values stored or released were shown to be highest at 5 cm depth of soil layers. And it was reduced with increasing of depth of soil layers until 20 cm and was not changed under the soil layer of 20 cm depth. 4. The heat absorption rates of soil, the ratio between supplied and stored heat energy, fur both the system I and system II were lower than 23%.

옴가열이 전분의 열적 특성과 흡수력에 미치는 영향 (Effect of Ohmic Heating on Thermal and Water Holding Property of Starches)

  • 차윤환
    • 한국식품영양학회지
    • /
    • 제27권1호
    • /
    • pp.112-119
    • /
    • 2014
  • Ohmic heating uses electric resistance heat which occurs equally and rapidly inside food when the electrical current is transmitted into. Prior to the study, we have researched the potato starch's thermal property changes during ohmic heating. Comparing with conventional heating, the gelatinization temperature and the range of potato starch treated by ohmic heating are increased and narrowed respectively. Herein, we have studied thermal property changes of wheat, corn, potato and sweet potato starch by ohmic heating as well as conventional heating. And then we measure the water holding capacity of starches. Annealing of starch is a heat treatment method heated at 3~4% below the gelatinization point. This treatment changes the starch's thermal property. In the DSC analysis of this study, the $T_o$, $T_p$, $T_c$ of all starch levels have increased, and the $T_c$-$T_o$ narrowed. In the ohmic heating, the treatment sample is extensively changed but not with the conventional heating. From the ohmic treatment, increases from gelatinization temperature are potato ($8.3^{\circ}C$) > wheat ($5.3^{\circ}C$) > corn ($4.9^{\circ}C$) > sweet potato ($4.5^{\circ}C$), and gelatinization ranges are potato ($7.9^{\circ}C$), wheat ($7.5^{\circ}C$), corn ($6.1^{\circ}C$) and sweet potato ($6.8^{\circ}C$). In the case of conventional treatment, water holding capacity is not changed with increasing temperature but the ohmic heating is increased. Water holding capacity is related to the degree of gelatinization for starch. This result show that when treated with below gelatinization temperature, the starches are partly gelatined by ohmic treatment. When viewing the results of the above, ohmic treatment is enhanced by heating and generating electric currents to the starch structure.

BSCCO(2223) 초전도 선재의 접합공정 연구 (A Study of Joining Method of BSCCO(2223) Tape)

  • 김정호;김중석;김태우;지붕기;주진호;나완수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.1-7
    • /
    • 1999
  • we evaluated the effects of joining process such as contact method. shape of joined area and pressure on the electrical and mechanical properties of Bi-2223 superconducting tape, Specifically. the current capacity of the jointed tape was measured as a function of uniaxial pressure. and the thermal shock, bonding strength and the thermal of the tape were evaluated and correlated to the microstructural evolution. It was observed that the current capacity was significanrly dependent on the uniaxial pressure The jointed tape, fabricated with a pressure of 1,000-1,600 Mpa. showed the highest value of current capacity results from improvements in core density, contacting area and grain alignment, ect. In addition, the strength of jointed tape was measured to be 86 Mpa, which is about 88% of the unjoined ape's strength. The irreversible strain($\varepsilon$irrev) for the jointed tape was measured to be 0.1%, smaller than that of unjoined tape ($\varepsilon$irrev= 0.3%). The decrease in the strength and irreversible strain for jointed tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

경년열화가 증용량 저이도 송전선의 기계적특성에 미치는 영향 (II) (Effect of Mechanical Properties by a Long Term Operation in High Capacity and Low Sag Conductor ( II ))

  • 김상수;김병걸;신구용;이동일;민병욱
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.100-106
    • /
    • 2006
  • Today, restricted energy sources, environmental considerations and the high cost of transporting fuel have limited the number and location of available power plant sites. The pressures resulting from these conditions have tended to require the construction of long, high-capacity, high-voltage power lines. it's used to adapt to STACIR/AW(Super Thermal-resistant Aluminum alloy Conductors, aluminum-clad Invar-Reinforced) conductor for coping with these situations. STACIR/AW conductor was formed by the combination of INVAR/AW as the core for low sag and super thermal-resistant aluminum alloy conductor for current capacity increase. increase of temperature by current capacity and long span lines make the susceptible to the deterioration of thermo-mechanical properties(conductivity, tensile strength, E-modulus and twist property et al). In the present work, changes of thermo-mechanical properties with aging have been studied in STACIR/AW $410 mm^2$ conductor with forms of single wire and strand wire.

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

Effects of Mesh Size in a Flat Evaporator and Condenser Cooling Capacity on the Thermal Performance of a Capillary Pumped Loop

  • Boo, Joon-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.121-129
    • /
    • 2000
  • The thermal performance of a flat evaporator for capillary pumped loop (CPL) applications was investigated. Two to four layers of coarse wire screen wicks were placed onto the heated surface to provide irregular passages for vapor flow. The evaporator and condenser were separated by a distance of 1.2 m and connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for vapor and liquid lines was 9.35 mm or less in diameter and heat was removed from the condenser by convection of air. A heat flux of up to $4.9{\times}10^4$ $W/m^2$ was applied to a flat evaporator having dimensions of 100 mm by 200 mm, 20 mm thick. The thermal resistance of the system as well as the temperature characteristics of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied. The performance of the evaporator and effect of condenser cooling capacity were analyzed and discussed.

  • PDF

피복된 미립 상변화물질 슬러리를 이용한 대류 열전달의 향상에 관한 연구 (Enhancement of Convective Heat Transfer by Using a Micro-Encapsulated Phase-Change-Material Slurry)

  • 정동주;최은수
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1277-1284
    • /
    • 2000
  • To enhance heat transfer characteristics of water, micro-encapsulated octadecane of about $10{\mu}m$ diameter was added to water. Viscosity of the slurry was measured by using a capillary tube viscometer. The measured viscosity decreased as the temperature of the slurry increased, and it increased as the fraction of the capsules in the slurry increased. Thermal characteristics of the octadecane were studied by using a differential scanning calorimeter. The melting temperature and the melting energy of the octadecane were found to be $28.6^{\circ}$ and 34.4kcal/kg, respectively. The convective heat transfer characteristics of the slurry were investigated in a flow loop with a constant heat flux test section. Friction factor of the slurry flow was found to be similar to the expected curve by Petukhov. The Nusselt number of the slurry flow was highest when the octadecane melted. Effective thermal capacity of the 14.2% slurry was found to have 1.67 times of the thermal capacity of water.

커버플레이트를 이용한 다단계 온도프리스트레싱으로 보강된 합성보의 하중-저항성능 분석 (Load-Carrying Capacity Evaluation of the Composite Beam Strengthened by Multi-Stepwise Thermal Prestressing Method Using Cover-Plate)

  • 안진희;정치영;최규태;김상효
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권4호통권56호
    • /
    • pp.159-169
    • /
    • 2009
  • 본 연구는 다단계 온도프리스트레싱 공법으로 보강된 합성보의 하중재하 실험 및 구조해석을 통하여 온도프리스트레싱 공법의 프리스트레스 도입효과와 단면증가효과를 평가하였다. 연구결과 온도프리스트레싱을 이용한 합성보의 보강공법은 온도프리스트레싱에 의한 프리스트레스 도입 뿐 아니라 커버플레이트의 설치에 의한 단면증가로 합성보의 처짐 또한 감소시킬 수 있으므로 합성보의 효율적인 보강공법으로 적용이 가능할 것이다.