• 제목/요약/키워드: thermal analysis simulation

검색결과 1,222건 처리시간 0.025초

동적열해석프로그램을 이용한 대형할인매장의 에너지 소비 특성 분석 (The Energy Performance Analysis of Large Scale Store Using Dynamic Thermal Analysis Simulation Program)

  • 김병수;홍원표
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.44-49
    • /
    • 2010
  • The purpose of this study is to analyze the situation of energy consumption and its characteristics in large scale store. The related survey is carried out in large scale store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and others. The area of large scale discount store is about $65000m^2$, located in Daejeon. For Annual Energy Analysis of building, We surveyed used energy for 1 year and simulated using a building energy simulation(TRNSYS 16). The results of this study are as follows. 1)The amount of annual total energy consumption are 18615.244MWh/yr(286.4KWh/$m^2yr$), The rate of heating, cooling and base energy(for hot water, lighting, ventilation, equipments, cooking and others) is 3054MWh/yr(47kWh/$m^2yr$), 5660.09MWh/yr(87.08kWh/$m^2yr$), 9900.47MWh/yr(152.31KWh/$m^2yr$) respectively. The total used energy is higher than others building in Korea. Especially, The energy consumption of large scale store is very depends on operating period and pattern such as space temperature, occupancy, lighting system, equipments operating schedule and etc.

COB, COH Package LED Module 열 해석 시뮬레이션 (COB, COH Package LED Module Thermal Analysis Simulation)

  • 최금연;어익수
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5117-5122
    • /
    • 2011
  • 본 논문에서는 열 해석 시뮬레이션 프로그램인 COMSOL Multiphysics를 활용하여, LED Module의 제작 시, 가장 선호되는 패키지 종류인 COB Type과 보드를 생략한 COH Type의 열 해석 시뮬레이션을 진행한다. LED Module의 시뮬레이션 결과 방열판을 통과하는 위치에 따라 COB Type은 Max. 약 $78^{\circ}C$ ~ Min. 약 $62^{\circ}C$, COH Type은 Max. 약 $88^{\circ}C$ ~ Min. 약 $67^{\circ}C$에서 온도가 안정이 됨을 확인하였다. COB Type과 비교하여 Max. 온도는 약 $10^{\circ}C$ 차이가 나지만, Min. 온도에서 약 $5^{\circ}C$정도로 격차가 감소함을 확인하였으며, LED Point 온도특성곡선을 확인 한 결과 COB Type은 Max. 약 $100^{\circ}C$ ~ Min. 약 $77^{\circ}C$, COH Type은 Max. 약 $100^{\circ}C$ ~ Min. 약 $86^{\circ}C$온도가 안정이 됨을 확인하였으며, COB Type에 비해 COH Type이 약 $10^{\circ}C$ 온도가 높게 측정되었다.

지열 발전을 위한 HFC-245fa 유기 랭킨 사이클의 성능해석 (Analysis of HFC-245fa organic Rankine cycle for geothermal power generation)

  • 백영진;김민성;장기창;윤형기;이영수;나호상
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 2009
  • In this study, an ORC (Organic Rankine Cycle) is investigated for a low-temperature geothermal power generation by a simulation method. A steady-state simulation model is developed to analyze cycle's performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump are modelled by an isentropic efficiency. Simulations were carried out for the given heat source and sink inlet temperatures, and given flow rate that is based on the typical power plant thermal-capacitance-rate ratio. HFC-245fa is considered as a working fluid of the cycle. Simulation results, at the given secondary working fluids conditions, show that even though the power can be presented by both the evaporating temperature and the turbine inlet superheat, it depends on the evaporating temperature primarily.

  • PDF

A SUMMARY OF 50th OECD/NEA/CSNI INTERNATIONAL STANDARD PROBLEM EXERCISE (ISP-50)

  • Choi, Ki-Yong;Baek, Won-Pil;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제44권6호
    • /
    • pp.561-586
    • /
    • 2012
  • This paper describes a summary of final prediction results by system-scale safety analysis codes during the OECD/NEA/CSNI ISP-50 exercise, targeting a 50% Direct Vessel Injection (DVI) line break integral effect test performed with the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS). This ISP-50 exercise has been performed in two consecutive phases: "blind" and "open" phases. Quantitative comparisons were performed using the Fast Fourier Transform Based Method (FFTBM) to compare the overall accuracy of the collected calculations. Great user effects resulting from the combination of the possible reasons were found in the blind phase, confirming that user effect is still one of the major issues in connection with the system thermal-hydraulic code application. Open calculations showed better prediction accuracy than the blind calculations in terms of average amplitude (AA) value. A total of nineteen organizations from eleven countries participated in this ISP-50 program and eight leading thermal-hydraulic system analysis codes were used: APROS, ATHLET, CATHARE, KORSAR, MARS-KS, RELAP5/MOD3.3, TECH-M-97, and TRACE.

Uncertainty analysis of heat transfer of TMSR-SF0 simulator

  • Jiajun Wang;Ye Dai;Yang Zou;Hongjie Xu
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.762-769
    • /
    • 2024
  • The TMSR-SF0 simulator is an integral effect thermal-hydraulic experimental system for the development of thorium molten salt reactor (TMSR) program in China. The simulator has two heat transport loops with liquid FLiNaK. In literature, the 95% level confidence uncertainties of the thermophysical properties of FLiNaK are recommended, and the uncertainties of density, heat capacity, thermal conductivity and viscosity are ±2%, ±10, ±10% and ±10% respectively. In order to investigate the effects of thermophysical properties uncertainties on the molten salt heat transport system, the uncertainty and sensitivity analysis of the heat transfer characteristics of the simulator system are carried out on a RELAP5 model. The uncertainties of thermophysical properties are incorporated in simulation model and the Monte Carlo sampling method is used to propagate the input uncertainties through the model. The simulation results indicate that the uncertainty propagated to core outlet temperature is about ±10 ℃ with a confidence level of 95% in a steady-state operation condition. The result should be noted in the design, operation and code validation of molten salt reactor. In addition, more experimental data is necessary for quantifying the uncertainty of thermophysical properties of molten salts.

Finite-element modeling and analysis of time-dependent thermomechanical distortion of optical sheets in a LCD module

  • Lee, Jae-Won;Hwang, Hak-Mo;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1436-1441
    • /
    • 2006
  • Each type of optical sheets in a LCD module experiences a characteristic behavior for thermal loading and unloading. During thermal cycling, a polymeric behavior is reversible and recyclable, depending on a material stiffness critically affected by temperature and time. Some critical issues on temperature- and time-dependent themomechanical deformation of the polymeric sheet are addressed by finite-element thermal results, followed by structural simulation results in this study.

  • PDF

SMC 압축성형 공정에 관한 유한요소해석 (Finite Element Analysis of SMC Compression Molding Processes)

  • 이충호;허훈
    • 소성∙가공
    • /
    • 제4권3호
    • /
    • pp.204-213
    • /
    • 1995
  • A finite element program is developed to analyze the flow phenomena in SMC compression molding as a viscoplastic model. The calculation of temperature distribution is also carried out by uncoupling the thermal analysis from the flow analysis. SMC molding processes with a flat plate substructure and the one with a T-shaped rib are considered in numerical simulation. The numerical results provide deformed shapes, temperature distribution in a SMC charge, and the forming load. The simulation of compression molding of a flat plate with a T-shaped rib requires a remeshing technique for the whole process.

  • PDF

사무소 건설의 설계변수 열성능 평가 및 부하예측방정식 개발 (Thermal Performance Evaluation of Design Parameters and Development of Load Prediction Equations of Office Buildings)

  • 석호태;김광우
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.914-921
    • /
    • 2001
  • The objective of this study is to evaluate the design parameters and to develop the cooling and heating load prediction equations of office buildings. The building load calculation simulation was carried out using the DOE-2.1E program. The results of the simulation was used as a data for ANOVA and multiple regression analysis which could develop the load prediction equations.

  • PDF

Study on The Development of Basic Simulation Network for Operational Transient Analysis of The CANDU Power Plant

  • Park, Jong-Woon;Lim, Jae-cheon;Suh, Jae-seung;Chung, Ji-bum;Kim, Sung-Bae
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.423-428
    • /
    • 1995
  • Simulation models have been developed to predict the overall behavior of the CANDU plant systems during normal operational transients. For real time simulation purpose, simplified thermal hydraulic models are applied with appropriate system control logics, which include primary heat transport system solver with its component models and secondary side system models. The secondary side models are mainly used to provide boundary conditions for primary system calculation and to accomodate plant power control logics. Also, for the effective use of simulation package, hardware oriented basic simulation network has been established with appropriate graphic display system. Through validation with typical plant power maneuvering cases using proven plant performance analysis computer code, the present simulation package shows reasonable capability in the prediction of the dynamic behavior of plant variables during operational transients of CANDU plant, which means that this simulation tool can be utilized as a basic framework for full scope simulation network through further improvements.

  • PDF

Climate Analysis Seoul (CAS)를 이용한 서울 도심 녹지 주변의 열 환경 분석 (Analysis of the Thermal Environment around an Urban Green Area in Seoul, Korea Using Climate Analysis Seoul (CAS))

  • 이지수;이영곤;김백조
    • 대기
    • /
    • 제26권3호
    • /
    • pp.413-421
    • /
    • 2016
  • Climate Analysis Seoul (CAS) which provides gridded data relevant for thermal assessment was applied to one of the urban green areas, the Seonjeongneung, in Seoul, Korea. The thermal environment in the Seonjeongneung was evaluated from the CAS simulation for the five heat-wave issued cases during the last five years (2011~2015). The CAS has been improved continuously since it was developed. An updated version with a higher resolution of the CAS simulation domain and an addition of the vegetation information was used in this study. The influence of vegetation in the Seonjeongneung is estimated through the amount of the cold air generation ($Q_{ca}$) and air temperature deviation at each grid points, which are calculated by incorporating Geographic Information System (GIS) analysis on the simulation domain and meteorological analysis with the METeorology and atmospheric PHOtochemistry mesoscale MODel (MetPhoMod) in the CAS. The average amount of the cold air generation ($Q_{ca}$) at the Seonjeongneung is about $25.5m^3m^{-2}h^{-1}$ for the whole cases, and this value is similar to the ones in a forest or a well-wooded region. The average value of the total air temperature deviation (TD) is $-2.54^{\circ}C$ at the Seonjeongneung for the five cases. However, this cooling effect of the urban green area disappeared when the region is replaced by high-rise buildings in the CAS simulation. The $Q_{ca}$ drastically decreases to about $1.1m^3m^{-2}h^{-1}$ and the average TD shows an increase of $1.14^{\circ}C$ for the same events. This result shows that the vegetation in the Seonjeongneung supposes to keep down temperature during the heat-wave issued day and the average cooling effect of the green region is $3.68^{\circ}C$ quantitatively from the TD difference of the two simulations. The cooling effect represented with the TD difference is larger than $0.3^{\circ}C$ within 200 m distance from the boundary of the Seonjeongneung. Further improvements of the thermodynamical and advection processes above the model surface are required to consider more accurate assessment of the cooling effect for the urban green area.