• Title/Summary/Keyword: the power method

Search Result 22,377, Processing Time 0.045 seconds

A CLB-based CPLD Low-power Technology Mapping Algorithm considered a Trade-off

  • Youn, Choong-Mo;Kim, Jae-Jin
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.1
    • /
    • pp.59-63
    • /
    • 2007
  • In this paper, a CLB-based CPLD low-power technology mapping algorithm considered a Trade-off is proposed. To perform low-power technology mapping for CPLDs, a given Boolean network has to be represented in a DAG. The proposed algorithm consists of three steps. In the first step, TD(Transition Density) calculation has to be performed. Total power consumption is obtained by calculating the switching activity of each node in a DAG. In the second step, the feasible clusters are generated by considering the following conditions: the number of inputs and outputs, the number of OR terms for CLB within a CPLD. The common node cluster merging method, the node separation method, and the node duplication method are used to produce the feasible clusters. In the final step, low-power technology mapping based on the CLBs packs the feasible clusters. The proposed algorithm is examined using SIS benchmarks. When the number of OR terms is five, the experiment results show that power consumption is reduced by 30.73% compared with TEMPLA, and by 17.11 % compared with PLA mapping.

Voltage Source Equipment for the Grid Fault Testing and Analysis of Total Harmonic Distortion According to PWM Methods

  • Gwon, Jin-Su;Kim, Chun-Sung;Kang, Dae-Wook;Park, Jung-Woo;Kim, Sungshin
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1081-1092
    • /
    • 2014
  • Renewable energy is being spotlighted as the electric power generating source for the next generation. Due to an increase in renewable energy systems in the grid system, their impact on the grid has become non-negligible. Thus, many countries in the world, including Europe, present their own grid codes for grid power conversion devices. In order to experiment with these grid codes, grid fault test equipment is required. This paper proposes both equipment and a control method, which are constructed with a 7-level cascaded H-bridge converter, that are capable of generating various grid faults. In addition, the Pulse Width Modulation (PWM) method for multilevel converters is compared and analyzed. The proposed structure, the control method, and the PWM method are verified through simulation and experimental results.

Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling (포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

A PROJECTION ALGORITHM FOR SYMMETRIC EIGENVALUE PROBLEMS

  • PARK, PIL SEONG
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.3 no.2
    • /
    • pp.5-16
    • /
    • 1999
  • We introduce a new projector for accelerating convergence of a symmetric eigenvalue problem Ax = x, and devise a power/Lanczos hybrid algorithm. Acceleration can be achieved by removing the hard-to-annihilate nonsolution eigencomponents corresponding to the widespread eigenvalues with modulus close to 1, by estimating them accurately using the Lanczos method. However, the additional Lanczos results can be obtained without expensive matrix-vector multiplications but a very small amount of extra work, by utilizing simple power-Lanczos interconversion algorithms suggested. Numerical experiments are given at the end.

  • PDF

A Method to Monitor the Reliability of In-house Power Supply Systems in Nuclear Power Plants Based on Probabilistic Assessment (확률론적 평가를 이용한 원자력발전소 소내전력공급계통 신뢰도 감시 방법)

  • Park, Jin-Yeub;Jerng, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.444-449
    • /
    • 2009
  • This paper introduces a method to establish performance criteria of the in-house power supply system in nuclear power plants. The performance criteria of the system is presented in terms of the number of function failures and amount of the out-of-service time that can be allowed commensurate with the probabilistic safety assessment results of the nuclear power plants. To obtain the performance criteria such as reliability and availability, the functions of the system were analyzed and probabilistic assessment results were utilized. This method provides quantitative guidelines in selecting and monitoring system functions to determine an adequate level of maintenance quality in order to ensure the probabilistic goals for the safety of the nuclear power plants.

A Study on the High-Accuracy Power Meter and Reliability Verification Plan (고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구)

  • Lee, Sanghun;LEE, Changhwa
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

Low Power Smart Sensing Algorithm based on Context Aware (상황인지 기반 스마트 저전력 센싱 기술)

  • Kim, Seong-Joong;Park, Woo-Chool;Seo, Hae-Moon;Park, Man-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.44-47
    • /
    • 2011
  • In this paper, we propose context-aware based on Low Power Sensing Algorithm. The proposed sensing algorithm reduces power consumptions using low-power sensing algorithms and low-power sensing protocols. Experimental results show that the average power consumption of the proposed method is up to half consumption that of the conventional method.

Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines (자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법)

  • Kwon, Gookmin;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

An Improved Variable Step Size MPPT Algorithm Based on INC

  • Xu, Zhi-Rong;Yang, Ping;Zhou, Dong-Bao;Li, Peng;Lei, Jin-Yong;Chen, Yuan-Rui
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.487-496
    • /
    • 2015
  • In order to ensure that photovoltaic (PV) systems work at the maximum power point (MPP) and maximize the economic benefits, maximum power point tracking (MPPT) techniques are normally applied to these systems. One of the most widely applied MPPT methods is the incremental conductance (INC) method. However, the choice of the step size still remains controversial. This paper presents an improved variable step size INC MPPT algorithm that uses four different step sizes. This method has the advantages of INC but with the ability to validly adjust the step size to adapt to changes of the PV's power curve. The presented algorithm also simultaneously achieves increased rapidity and accuracy when compared with the conventional fixed step size INC MPPT algorithm. In addition, the theoretical derivation and specific applications of the proposed algorithm are presented here. This method is validated by simulation and experimental results.

Analysis on Attraction Power and Holding Power of Exhibition Areas at Science Museum(II) - Focused on Analysis on Exhibition Method of Exhibition Spaces - (과학계 박물관 전시공간의 흡입력과 지속력 분석(II) - 전시영역별 연출매체의 분포특성 분석을 중심으로 -)

  • Lim, Che-Zinn;Choo, Sung-Won;Park, Moo-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.4
    • /
    • pp.174-182
    • /
    • 2011
  • This study analyzed visitors' behaviors in the viewpoint of Attraction Power and Holding Power of exhibits on the basis of exhibition layout of real science museums. Through the analysis, the study grasped efficiency of analysis index and exhibition environment elements which might have an effect on planning the exhibition space of a large-scale museum and producing detailed ranges of exhibition. The main indicators used are: 1. Attraction Power: it indicates the relative incidence of people who have stopped in front of an object/exhibit during the exhibition tour. It is calculated by dividing the number of people who stop by the total number of people who have visited the museum or gallery. 2. Holding Power: it measures the average time spent in front of an information/communication element. It is calculated by dividing the average time of stay by the time "necessary" to read an element. As a result of analyzing the exhibition areas of National Science Museum (Daejeon) and National Museum of Emerging Science and Innovation(Tokyo), the Holding Power was found to be relatively lower than the Attracting Power. This means that 3.5 out of 10 visitors stop in front of the exhibit in 6 exhibition areas, and among these, only 1/10 is used when compared to the user required time of the exhibits. In other words, like the method of deriving an analysis index, the stage of viewing can be categorized as Attracting Power and Holding Power, and because the stage from Attracting Power to the stage of Holding Power are strongly linked, it shows that it is not easy to display a meaningful result. Except, the general distribution of Attracting Power was shown to be high from the entrance area of the exhibition hall based on the standard of viewing sequence. Also, the Holding Power became sequentially lower according to the sequence of exhibition viewing and displayed a meaningful interrelationship with the distribution ratio of island exhibits. In the case of island exhibition method, it is less influenced by the movement flow of visitors when compared to the wall type method of exhibition and can be understood as an exhibition method that provides spatial chances enabling stopping and viewing.