• Title/Summary/Keyword: the mean

Search Result 49,917, Processing Time 0.058 seconds

A Study on the Correlation of Mean Velocity of Basilar Artery and Equilibrium Function with Sasang Constitution (체질에 따른 기저동맥 평균 혈류속도와 균형 기능과의 상관관계에 대한 연구)

  • Lee, Joo-Yong;Choi, Jae-Song;Bae, Na-Young;Ahn, Taek-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.22 no.4
    • /
    • pp.30-39
    • /
    • 2010
  • 1. Objectives This study was carried out to investigate the equilibrium functional difference according to mean velocity of basilar artery with Sasang Constitution. 2. Methods We analyzed the data of 300 adults(194 males, 106 females), who visited oriental hospital of D university for medical examiation, which includes Sasang constitution examination, equilibrium function test, transcranial doppler ultrasonography(TCD). We evaluated the trace length and envelop area of open eyes and closed eyes, mean velocity of basilar artery and analyzed its statistical data. 3. Results and Conclusions 1) Within all subjects, trace length and envelop area of closed eyes were significantly lower, in the order of increased mean velocity of basilar artery group, normal mean velocity of basilar artery group and decreased mean velocity of basilar artery group. 2) No significantly difference was seen between the mean velocity of basilar artery and equilibrium function in Soyangin and Soeumin. 3) When closed eyes, trace length were significantly lower in order of increased mean velocity of basilar artery group, normal mean velocity of basilar artery group and decreased mean velocity of basilar artery group, in Taeeumin.

Nonparametric Estimation of Mean Residual Life by Partial Moment Approximation under Proportional Hazard Model

  • Cha, Young-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.965-971
    • /
    • 2004
  • In this paper we consider several nonparametric estimators for the mean residual life by using the partial moment approximation under the proportional hazard model. Also we compare the magnitude of mean square error of the proposed nonparametric estimators for mean residual life under the proportional hazard model.

  • PDF

ON THE r-TH HYPER-KLOOSTERMAN SUMS AND ITS HYBRID MEAN VALUE

  • Zhang, Tianping;Zhang, Wenpeng
    • Journal of the Korean Mathematical Society
    • /
    • v.43 no.6
    • /
    • pp.1199-1217
    • /
    • 2006
  • The main purpose of this paper is using the properties of Gauss sums, primitive characters and the mean value theorems of Dirichlet L-functions to study the hybrid mean value of the T-th hyper-Kloosterman sums Kl(h, k+1, r;q) and the hyper Cochrane sums C(h, q; m, k), and give an interesting mean value formula.

Tests for Normal Mean Change with the Mean Difference

  • Kim, Jaehee;Yun, Pilkyoung
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.2
    • /
    • pp.353-359
    • /
    • 2003
  • This paper deals with the problem of testing mean change with one change-point with the normal random variables. We propose a test with the mean difference for change in a location parameter. A power comparison study of various change-point test statistics is performed via Monte Carlo simulation with S-plus software.

MEAN ORBITAL ELEMENTS FOR GEOSYNCHRONOUS ORBIT -II -Orbital inclination, longitude of ascending node, mean longitude- (정지위성 궤도의 평균 궤도 요소 - II -궤도 경사각, 승교점 경도, 위성 경도-)

  • 최규홍;박종옥;문인상;배성구
    • Journal of Astronomy and Space Sciences
    • /
    • v.7 no.1
    • /
    • pp.11-21
    • /
    • 1990
  • The osculating orbital elements include the mean, secular, long period, and short period terms. The iterative algorithm used for conversion of osculating orbital elements to mean orbital elements is described. The mean orbital elements of $W_c,\;W_s$, and L are obtained.

  • PDF

The Effects of the Combined Patterns of Proprioceptive Neuromuscular Facilitation on Static Balance (고유수용성 신경근 촉진법의 통합 패턴이 정적 균형에 미치는 영향)

  • Choi, Won-Jye;Kim, Yoon-Hwan;Lee, Seung-Yub
    • PNF and Movement
    • /
    • v.6 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Purpose : The purpose of this study was to investigate the effects of the combined patterns of PNF(proprioceptive neuromuscular facilitation) on the static balance ability. Methods : The measurements of the static balance ability were completed by 10 subjects for 6 weeks, from October to November 2007. The combined patterns of PNF were carried out by means of self-exercising suggested by Dietz, which were designed as four cases: two positions (standing and quadruped) for both patterns(sprinter and skater), respectively. The exercises were practiced once a day, 3 times a week in same condition. By using the GOOD BALANCE system, assessment of the static balance ability was taken at before and after exercise from 6 positions: normal standing, one leg left and one leg right standing when eye open and close, respectively. For each case, the experimental data was obtained in 3 items: mean X speed, mean Y speed and velocity moment. Results : The results of this study were as follows : 1. There were statistically significant differences of Mean X speed, Mean Y speed and Velocity moment between the before and the after exercise in the case of normal standing when eye open and close(NSEO and NSEC), respectively. 2. There was statistically significant difference of Mean X speed between the before and the after exercise in the case of one leg left standing when eye open(OLLEO). In this case, however, the statistically significant differences were not found in both terms of Mean Y speed and Velocity moment. 3. There were statistically significant differences of Mean X speed and Mean Y speed between the before and the after exercise in the case of one leg left standing when eye close(OLLEC). In this case, however, the statistically significant difference was not found in term of Velocity moment. 4. There were statistically significant differences of Mean X speed, Mean Y speed and Velocity moment between the before and the after exercise in the case of one leg right standing when eye close(OLREC). 5. There was statistically significant difference of Mean X speed between the before and the after exercise in the case of one leg right standing when eye open(OLREO). In this case, however, the statistically significant differences were not found in both terms of Mean Y speed and Velocity moment. 6. There were statistically significant differences of total Mean X speed, total Mean Y speed and total Velocity moment between the before and the after exercise. Conclusions : The above results from this study indicated that the combined patterns of PNF have improved the static balance ability. However the used self-exercise can be applied to normal people, i.e., the exercise is difficult to apply into clinical patients. The further study should be focused at development of various modified forms of the combined patterns of PNF in keeping up the improvement effect of this exercise.

  • PDF

An Efficient Method Of The Suspended Sediment-Discharge Measurement Using Entropy Concept

  • Choo, Tai-Ho
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2000
  • A method is presented which enables easily the computation of the suspended sediment discharge as the mean sediment concentration and mean flow velocity. This method has significant advantages over the traditional method, which principally depend on a set of measured concentration data. The method is based on both a new sediment concentration and mean sediment concentration equations which have been derived from the entropy concept used in statistical mechanics and information theory: (1) The sediment concentration distribution equations derived, are capable of describing the variation of the concentration in the vertical direction. (2) The mean concentration equation derived, is capable of calculating easily the mean concentration by using only one measured concentration in open channel. The present study mainly addresses the following two subjects : (1) new sediment concentration and mean sediment concentration equations are derived from the entropy concept : (2) An efficient and useful method of suspended sediment-discharge measurements is developed which can facilitate the estimation of suspended sediment-discharge in open channel. Flume and laboratory data are used to carry out the research task outlined above. An efficient method for determining the suspended sediment-discharge in the open channel has been developed. The method presented also is efficient and applicable in estimating the sediment transport in rivers and the sediment deposit in the reservoirs, and can drastically reduce the time and cost of sediment measurements.

  • PDF

EFFECTS OF DIFFERENT PREPARATION METHODS ON THE MORPHOLOGIC CHANGE OF SIMULATED ROOT CANALS IN RESIN BLOCK (수종 근관형성방법에 따른 레진모형상의 근관형태의 변화)

  • Park, Mi-Hee;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.85-96
    • /
    • 1994
  • In this study, 24 curved resin blocks were prepared by one of the following four methods: 1) Conventional technique using K-flexo files 2) Step-back technique using K-flexo files 3) Crown-down technique using K-flexo files 4) Canal Master instrumentation using Canal Master Resin blocks were sectioned, photographed, and evaluated the mean centering ratio and the mean area of dentin removed before and after the instrumentation. The results were as follows : I. the mean centering ratio 1. In the level 1 and level 3, there was no significant difference in the mean centering ratio. 2. In the level 2, Step-back technique showed the worst mean centering ratio among the tested groups(p<0.001) and there was no significant difference between the other three groups. 3. In the level 4, Canal Master instrumentation and Step-back technique showed better mean centering ratio than the other two techniques(p<0.001) and there was no significant difference between the two techniques. II. the mean area of dentin removed 1. In the level l and level 3, there was no significant difference in the mean area of dentin removed. 2. In the level 2, Canal Master instrumentation removed less dentin than the other three techniques(P<0.01). 3. In the level 4, Crown-down technique removed less dentin than the other three techniques(P<0.05).

  • PDF