• Title/Summary/Keyword: the ground vibrations

Search Result 166, Processing Time 0.024 seconds

A Study on the Construction Vibrations Prediction of Bridge Structures using the Reliability Index (신뢰성 지수를 이용한 교량 구조물의 건설진동 예측에 관한 연구)

  • 박연수;우정하;전양배;김응록;김동현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.442-449
    • /
    • 2003
  • This study presents a new analysis of blast vibration equations of a bridge structures using a reliability index. Changing the reliability makes each blast vibration equation. The blast equations are divided into three classes, having 50%, 90% and 99.9% at ${\beta}$=0, 1.28 and 3 respectively. In the result of this research, the assumption equations which used ${\beta}$=1.28 is suitable. By using these blast equations, it is possible for users to predict reliable ground vibration values upon demand.

  • PDF

Effects of multiple MR dampers controlled by fuzzy-based strategies on structural vibration reduction

  • Wilson, Claudia Mara Dias
    • Structural Engineering and Mechanics
    • /
    • v.41 no.3
    • /
    • pp.349-363
    • /
    • 2012
  • Fuzzy logic based control has recently been proposed for regulating the properties of magnetorheological (MR) dampers in an effort to reduce vibrations of structures subjected to seismic excitations. So far, most studies showing the effectiveness of these algorithms have focused on the use of a single MR damper. Because multiple dampers would be needed in practical applications, this study aims to evaluate the effects of multiple individually tuned fuzzy-controlled MR dampers in reducing responses of a multi-degree-of-freedom structure subjected to seismic motions. Two different fuzzy-control algorithms are considered, a traditional controller where all parameters are kept constant, and a gain-scheduling control strategy. Different damper placement configurations are also considered, as are different numbers of MR dampers. To determine the robustness of the fuzzy controllers developed to changes in ground excitation, the structure selected is subjected to different earthquake records. Responses analyzed include peak and root mean square displacements, accelerations, and interstory drifts. Results obtained with the fuzzy-based control schemes are compared to passive control strategies.

Non-Stationary Response of a Vehicle Obtained From a Series of Stationary Responses

  • Karacay, Tuncay;Akturk, Nizami;Eroglu, Mehmet;Ba
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1565-1571
    • /
    • 2004
  • Ride characteristics of a vehicle moving on a rough ground with changing travel velocity are analyzed in this paper. The solution is difficult due to the non-stationary characteristics of the problem. Hence a new technique has been proposed to overcome this difficulty. This new technique is employed in the analysis of ride characteristics of a vehicle with changing velocity in the time/frequency domain. It is found that the proposed technique gives successful results in modelling non-stationary responses in terms of a series of stationary responses.

Fatigue of tubular steel lighting columns under wind load

  • Peil, U.;Behrens, M.
    • Wind and Structures
    • /
    • v.5 no.5
    • /
    • pp.463-478
    • /
    • 2002
  • Lighting and traffic signal columns are mainly stressed by excitation due to natural, gusty wind. Such columns typically have a door opening about 60 cm above ground level for the connection of the buried cable with the column's electric system. When the columns around this notch are inadequately designed, vibrations due to gusty winds will produce considerable stress amplitudes in this area, which lead to fatigue cracks. To give a realistic basis for a reliable and economic design of lighting and traffic signal columns, a number of experimental and theoretical investigations have been made. The proposed design concept allows the life of such columns to be assessed with a satisfactory degree of accuracy.

Direct Ritz method for random seismic response for non-uniform beams

  • Lin, J.H.;Williams, F.W.;Bennett, P.N.
    • Structural Engineering and Mechanics
    • /
    • v.2 no.3
    • /
    • pp.285-294
    • /
    • 1994
  • Based on a fast and accurate method for the stationary random seismic response analysis for discretized structures(Lin 1992, Lin et al. 1992), a Ritz method for dealing with such responses of continuous systems in developed. This method is studied quantitatively, using cantilever shear beams for simplicity and clarity. The process can be naturally extended to deal with various boundary conditions as well as non-uniform Bernoulli-Euler beams, or even Timoshenko beams. Algorithms for both proportionally and non-proportionally damped responses are described. For all of such damping cases, it is not necessary to solve for the natural vibrations of the beams. The solution procedure is very simple, and equally efficient for a white or a non-white ground excitation spectrum. Two examples are given where various power spectral density functions, variances, covariances and second spectral moments of displacement, internal force response, and their derivatives are calculated and analyses. Some Ritz solutions are compared with "exact" CQC solutions.

Suggestion of Vibration Criteria for Fresh Concrete Considering Early Strength Increase (Fresh 콘크리트의 초기 강도 증가를 고려한 진동규준치 제안)

  • Park, Sun-Joon;Park, Yeon-Soo;Kang, Sung-Hoo;Kim, Hong-Ki;Kim, Eung-Rok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.453-460
    • /
    • 2002
  • In this paper, vibration criteria for fresh concrete are suggested considering relationship of strength and ages of concrete. Vibration criteria of fresh concrete subjected to construction vibration are not to be certain in abroad countries without question within a country. Before 12 hours cured, vibration criterion is suggested 0.25 cm/s. Used 4.0 cm/s by vibration criterion after 28 days. And the interval extent used relation with strength and ages of concrete. Vibration criteria proposed in this paper are thought may satisfy properties of fresh concrete as well as generally used those in domestic. Also, the actual ground vibrations due to pile driving have been measured, and data are analyze using the nitration equation applying to reliability index.

A Study on Delay Time Control for Lowering Grounding Vibration and Noise Induced by Blasting (발파에 의한 지반진동 및 소음 저감을 위한 지연시차 조절에 관한 연구)

  • Lee, Bong-Hyun;Choi, Sung-Oong
    • Explosives and Blasting
    • /
    • v.32 no.3
    • /
    • pp.18-25
    • /
    • 2014
  • Ground vibration and noise from blasting operation are known to be the most representative constituents which can cause human and material damage. In this study, the effect of delay time on ground vibration is investigated by adopting seven different delay times in bench blasting. For each delay time, three blasting operations were performed. The prediction equations for blasting vibration are derived from 50 sets of measurement and the time theory of Langefors is evoked in the analysis of the blasting vibrations and frequencies. For the delay times of 8 ms and 28 ms, the average values of ground vibration are 5.76 cm/sec and 5.75 cm/sec, respectively, which are considerably low. Also the cyclic variation in the vibration measurements with the delay time confirms the interference effect. From the application of the measurements of blasting vibration and frequency to the time theory of Langefors, it is concluded that the optimum delay times are 8 ms and 24 ms for the test site.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.

A Case Study on a Large Scale Borehole Test Blasting to Generate Man-made Earthquake (인공지진 발생을 위한 대규모 시추공 시험발파 사례연구)

  • Jeong, Ju-Hwan;Choi, Byung-Hee;Ryu, Chang-Ha;Min, Hyung-Dong;Choi, Hyung-Bin
    • Explosives and Blasting
    • /
    • v.27 no.2
    • /
    • pp.48-55
    • /
    • 2009
  • In the process of identifying the earth's crust structures to accurately locate the seismic epicenter, man-made earthquakes need to be generated. Such a large-scale ground vibration can be generated by a deep borehole blasting, but it can also accompany some environmental impacts on the surroundings. In this respect, a borehole test blasting was carried out to determine the maximum charge weight that could be used without affecting the various structures around the blast site. Total 400kg of gelatine-type dynamites was used in the test blast. As a result, a prediction equation for ground vibrations was derived from the measured data. With the allowable level of 3.0 mm/s for residential structures, the maximum charge weight was determined to be 677kg if military structures near the site were considered. But if the military structures were not considered, it was found that up to 2100kg of explosives could be used without affecting old houses in the nearby village.

Estimation of Ground Vibrations Around a Pillar Due to Blast Loading and the Impact of Flyrocks (발파하중 및 비석의 충격에 의한 광주의 지반진동의 예측 연구)

  • Lee, Sang-Gon;Kang, Choo-Won;Chang, Ho-Min;Ryu, Pog-Hyun;Kim, Jang-Won;Song, Ha-Rim;Kim, Seung-Eun
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • In blasting for lighting, fatigue behaviors of pillars such as destruction and deformation may occur due to blasting vibration and flyrock, which may cause collapses of cavities. This study aims to identify dynamic behavior of pillars to maintain efficient safety of cavities in large drafts. when they collide with flyrocks under blasting for the excavation. For the purpose, we compared ground vibration around pillar when flyrock collided with the pillar and that when explosive blast happened for the excavation. we conducted fragmentation analysis of the flyrock and compared impact vibration obtained from empirical equation with ground vibration obtained from regression analysis of real vibration data. also we compared those with results analyzed from numerical analysis.