Abstract
Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.
도심지 특성상 주변구조물에 근접한 발파로 발생되는 지반진동은 인체에 간접피해와 구조물에 물적피해를 줄 수 있다. 설계단계 또는 시공 전 민원발생 시 구조물의 피해정도를 평가하는 방법으로는 단순 진동파형을 정량적으로 표현하는데 가장 접근성이 좋은 시추공 발파시험이 주로 이용되고 있다. 본 연구는 소량의 폭약으로 인위적인 진동에너지를 발생시키는 발파시험에 전자뇌관 기폭시스템을 처음 적용하였다. 전기뇌관 시추공 발파와 전자뇌관 시추공발파의 뇌관 지연시차 상관관계, 시험장소의 터널본선과 유사 암층에 시설된 구조물에서 측정한 PPV와 서로 다른 매개 층을 포함한 터널상부 지상도로에서 측정한 PPV의 상관관계, 기존 연구결과 얻어진 시추공발파 및 터널발파 PPV와의 상관관계를 비교 분석하여 시추공 발파의 유용성과 뇌관 지연시차의 중요성을 언급하고자 한다.