• 제목/요약/키워드: the double ray

검색결과 481건 처리시간 0.025초

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF

양측폐에 발생한 종괴 (A Case of Large Mass on Both Lung)

  • 한민수;강홍모;유지홍
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권1호
    • /
    • pp.234-237
    • /
    • 1998
  • A 64-year-old male was admitted due to weight loss of 5kg during a month. Chest X-ray showed two large, lobulated masses on both lower lobe. Chest CT showed ill-defined, multilobulated mass on left lower lobe and irregular, relatively homogenous mass with air-bronchogram on right lower lobe. Left lower lobectomy and right lower lobectomy was performed sequentially with three months interval. Microscopic findings showed squamous cell carcinoma of both mass. It was thought that this patient had synchronous double primary lung cancer.

  • PDF

라미노그라피를 이용한 전자회로기판의 납땜부 형상 복원 (Shape reconstruction of solder joints on PCB using laminography)

  • 박원식;강성택;김형철;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.264-267
    • /
    • 1996
  • This paper is aimed to develop a very reliable method for automatic inspection of the solder joints on PCBS. There have been lots of previous works using vision technologies, but they can not be used for inspecting BGA, FCA or other newly used devices. Thus we adopt X-ray technologies for solder joint inspection. We put our attention on reconstructing the 3D shapes of solder joints since it gives us the most detailed information on quality of solder joints. Laminography principle is used to reject the interferences from neighboring parts or leads. To verify the effectiveness of laminography, a simulation study is performed in the case of a solder joints on double sided PCB using.

  • PDF

AES/XPS를 이용한 Au/V, Au/Ti 박막의 표면산화물 분석 (Characterization of Surface Oxides in Gold Thin Films with V- and Ti- underlays by AES and XPS)

  • Kim, Jin -Young
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.100-105
    • /
    • 1992
  • Au/V, Au/Ti의 이중구조 박막을 대기 중에서 $500^{\circ}C$에서 열처리한 후 Auger electron spectroscopy(AES)와 X-ray photoelectron spectroscepy(XPS)를 이용하여 분석 하였다. 열처리 과정에서 Au와 SiO2 기판 사이의 V-와 Ti- 하층박막은 Au 표면 위에 산화 물을 형성하였다. 산화물의 화학조성은 Au/V, Au/Ti 박막에서 V2O5와 TiO2로 각각 판명되었다.

  • PDF

Cumambrin A in Chrysanthemum boreale Makino Preparation, X-ray Crystal Structure and $^{13}C-$ and $^1H$-NMR Study of Cumambrin A

  • Park, Ki-Hun;Jang, Dae-Sik;Choi, Sang Uk;Nam, Sang-Hae;Shiro, Mooto;Yang, Min-Suk
    • 생약학회지
    • /
    • 제27권3호
    • /
    • pp.207-211
    • /
    • 1996
  • Cumambrin A has been isolated from the dried flowers of Chrysanthemum boreale Makino. The complete $^1H$ and $^{13}C$ NMR assignment of cumambrin A was achieved from two-dimensional $^1H$-$^1H$ COSY and $^{13}C$-$^1H$ COSY spectra with the aid of homonuclear and heteronuclear double resonance experiments. The its structure has been verified by single crystal X-ray diffraction.

  • PDF

액정 소자의 위치 민감도 및 수차 특성에 대한 연구 (The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements)

  • 허태연;유호식;유장훈;박수한;정수진
    • 정보저장시스템학회논문집
    • /
    • 제1권1호
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

Spectral Analysis of $CO_2$ Corrosion Product Scales on 13Cr Tubing Steel

  • Lin, Guan-fa;Xu, Xun-yuan;Bai, Zhen-quan;Feng, Yao-rong
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.201-207
    • /
    • 2008
  • $CO_2$ corrosion product scales formed on 13 Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the paper. The surface and cross-section profiles of the scales were observed by scanning electron microscopy (SEM), the chemical compositions of the scales were analyzed using energy dispersion analyzer of X-ray (EDAX), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) to confirm the corrosion mechanism of the 13 Cr steel in the simulated $CO_2$ corrosion environment. The results show that the corrosion scales are formed by the way of fashion corrosion, consist mainly of four elements, i.e. Fe, Cr, C and O, and with a double-layer structure, in which the surface layer is constituted of bulky and incompact crystals of $FeCO_3$, and the inner layer is composed of compact fine $FeCO_3$ crystals and amorphous $Cr(OH)_3$. Because of the characteristics of compactness and ionic permeating selectivity of the inner layer of the corrosion product scales, 13 Cr steel is more resistant in $CO_2$ corrosion environment.

Structural Design of a Cathode-ray Tube (CRT) to Improve its Mechanical Shockproof Character

  • Park, Sang-Hu;Kim, Won-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1361-1370
    • /
    • 2006
  • An electronic beam mis-landing phenomenon on the RGB (red/green/blue) -fluorescent surface has been considered as one of serious problems to be solved in cathode-ray tube (CRT), which is generally caused by mechanical shock and vibration. In this work, structural design concepts on the major parts of the CRT, such as a frame, a shadow mask, and a spring, are studied to improve the mechanical shockproof character of a CRT by FEM-analyses and experimental approaches ; a frame is newly designed to have strength employing the double-corner-beads which reduces considerably the distortion of the frame and the shadow mask : the edge-bead of a shadow-mask is redesigned to maintain the wide curved surface of a shadow-mask after mechanical shock : finally, a spring supporting the frame and the shadow-mask is designed to have enough flexibility along drop-direction. As an example, a conventional type of a 15inch CRT was utilized to demonstrate the feasibility and usefulness of this work. Overall, some favorable information on the structural design of the CRT is achieved, and the mechanical shockproof character of a 15-inch CRT is improved in the degree of 3G $(1G=9.81m/s^2)$ as an average-value.

사파이어 웨이퍼 연마공정에서의 표면처리효과에 대한 X-선 회절분석 (X-ray diffraction analysis on sapphire wafers with surface treatments in chemical-mechanical polishing process)

  • 김근주;고재천
    • 한국결정성장학회지
    • /
    • 제11권5호
    • /
    • pp.218-223
    • /
    • 2001
  • 수평 Bridgman 방법으로 성장한 사파이어 인고트를 절단 연마한 후, 사파이어 결정기판의 표면을 우레탄 천 위에서 실리카 졸을 사용하여 폴리싱하였다. 표면의 결정성을 X-선 회절을 통하여 조사하였으며, 2중 결정회절에 의한 반치폭은 200~400 arcsec을 가지며, 결정 인고트의 절편화 또는 양면 연삭 연마에 따른 잔류응력에 의한 표면에서의 기계적인 스트레스에 의해 결정성이 손상되어진다. 화학-기계적인 폴리싱공정을 수행한 수에 표면처리로 $1,200^{\circ}C$로 4시간 열처리 및 산처리를 연속적으로 수행할 경우 결정성이 반치폭 8.3 arcsec까지 줄어들어 향상됨을 확인하였다.

  • PDF

Proton and γ-ray Induced Radiation Effects on 1 Gbit LPDDR SDRAM Fabricated on Epitaxial Wafer for Space Applications

  • Park, Mi Young;Chae, Jang-Soo;Lee, Chol;Lee, Jungsu;Shin, Im Hyu;Kim, Ji Eun
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권3호
    • /
    • pp.229-236
    • /
    • 2016
  • We present proton-induced single event effects (SEEs) and γ-ray-induced total ionizing dose (TID) data for 1 Gbit lowpower double data rate synchronous dynamic random access memory (LPDDR SDRAM) fabricated on a 5 μm epitaxial layer (54 nm complementary metal-oxide-semiconductor (CMOS) technology). We compare our radiation tolerance data for LPDDR SDRAM with those of general DDR SDRAM. The data confirms that our devices under test (DUTs) are potential candidates for space flight applications.