• Title/Summary/Keyword: the distribution of water flow

Search Result 1,191, Processing Time 0.04 seconds

Simulation of Velocity Distribution in the Lake "Paldang" using the RMA-2 Model (수리모형(RMA-2)을 이용한 팔당호의 유속분포 모의실험)

  • Shin, Dong-Seok;Kwun, Soon-Kuk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.18-23
    • /
    • 1999
  • A numerical model of flow velocity in the standing water system is presented. This model(RMA-2), based on the 2-dimensional unsteady momentum and continuity equations, uses finite element techniques to simulate the distribution of velocity over a spatial location of lakes. The present model represents an improvement over existing numerical water quality models in that it can model the unsteady state and can, therefore, cope with time with a spatial location of standing waters such as lakes and large reservoirs. The model thus allows the engineer to do more accurate estimation of water flows and thus water qualities in standing waters where directions and velocities of the flow become more important for the simulation of the water quality than in running waters. Tests for the data collected in the lake "Paldang" indicates that the model works well under limited circumstances. However, to be more accurate estimation of velocity with the present model, accumulation of data for the measurement of velocities and renovation of geometrical conditions of the lake would be needed.

  • PDF

Experimental Study on the Flow Characteristics of High Pressurized Jets Depending upon Aspect Ratio (노즐 형상비에 따른 고압 분사류의 유동특성에 관한 실험적 연구)

  • Namkung J.H.;Lee S.J.;Kim K.C.;Lee S.G.;Rho B.J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.233-236
    • /
    • 2002
  • The high-pressurized spray nozzle is used f3r special washing and cutting with strong impact force. The performance of this nozzle, which focused on spray penetration and radial dispersion, was mainly investigated to maximize the momentum and minimize the flow loss. Hence, our experimental research was conducted by changing the aspect ratio ranging from 0 to 3 with nozzle outlet of 1.1. The spray trajectory far high-pressurized water was experimentally investigated using PDPA diagnostics, which was available at spray downstream region. As the spray at upstream near the nozzle exit did not show the improved disintegration. The results showed empirical correlation with regard to non-dimensional axial velocity distribution, spray penetration, and radial spreading rate with photographic visualization.

  • PDF

A Study on the Characteristics of Stream Flow Path and Water System Distribution in Gugok Garden, Korea (한국 구곡원림(九曲園林)의 하천 유로 및 수계별 분포 특성)

  • Rho, Jae-Hyun;Choi, Young-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.39 no.4
    • /
    • pp.50-65
    • /
    • 2021
  • In this study, the water flow system by measuring the flow-way type and distance of flow path that composes the Gugok through literature survey, field survey, and map work on Gugok gardens in Korea whose existence has been confirmed, while investigating and analyzing watersheds, river orders, and river grades. It was intended to reveal the watershed distribution and stream morphological characteristics of the Gugok gardens and to use them as basic data for future enjoyment and conservation of the Gugok gardens. The conclusion of the study is as follows. First, Of the 93 Gugok gardens that have been confirmed to exist, it was found that 11 places(11.8%) were found to have a descending(top-down) type of Gugok that develops while descending along a stream. Second, As a result of analysis of the length of the flow path for each valley, Okryudonggugok(玉流洞九曲, Namsan-gugok) in Gimcheon, Gyeongsangbuk-do was found to have the shortest length of 0.44km among the surveyed valleys, while the flow distance of Muheulgugok(武屹九曲) located in Seongju-gun and Gimcheon-si, Gyeongsangbuk-do was 31.1km, showing the longest flowing distance. The average flow path length of the Gugok Garden in Korea was 6.24km, and the standard deviation was 4.63km, indicating that the deviation between the 'curved type'e and the 'valley type' was severe. In addition, 14(15.1%) Gugok gardens were found to be partially submerged due to dam construction. Third, As a result of analyzing the waters area where Gugok garden is located, the number of Nakdong river basins was much higher at 52 sites(55.9%), followed by the Hangang river basin at 27 sites(28.7%), the Geum river basin at 9 sites(9.7%), and the Yeongsan river and Seomjin river basins at 5(5.4%). Fourth, All Gugok gardens located in the Han river region were classified as the Han river system, and the Gugok garden located on the Nakdong river was classified as the main Nakdong river system, except for 7 places including 5 places in the Nakdong Gangnam Sea water system and 2 places in the Nakdong Gangdong sea water system. As a result of synthesizing the river order of the flow path where Gugok garden is located, Gugok, which uses the main stream as the base of Gugok, is 3 places in the Hangang water system, 5 places in the Nakdong river system, 2 places in the Geumgang water system, and 1 place in the Yeongsangam/Seomjin river system. A total of 11 locations(11.5%) were found, including 36 locations(38.2%) in the first branch, 29 locations(31.2%) in the second branch, and 16 locations(17.0%) in the third branch. And Gugok garden, located on the 4th tributary, was found to be Taehwa Five-gok(太華五曲) set in Yonghwacheon Stream in Cheorwon in the Han river system, and Hoenggyegok(橫溪九曲) in Yeongcheon Hoenggye Stream in the Nakdong river system. Fifth, As a result of the river grade analysis of the rivers located in the Gugok garden Forest, the grades of the rivers located in the Gugok garden were 13 national rivers(14.0%), 7 local first-class rivers(7.5%), and 74 local second-class rivers(78.5%) was shown.

The effect of forced convection on boiling heat transfer from a horizontal tube (수평 원관의 비등 열전달에서 강제대류의 영향)

  • 이승홍;이억수;정은행
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.558-568
    • /
    • 1998
  • This paper presents the results of experiments involving external forced convection on boiling heat transfer from electrically heated horizontal tube to water in cross flow. In these experiments, all of the following primary variables were varied: heat flux, cross flow velocity, pressure and degree of subcooling. Local surface temperatures were measured at nine peripheral positions. Surface temperature distributions are classified into four groups as a function of heat flux. The characteristics of the boiling curve at different velocity, degree of subcooling and pressure are examined.

  • PDF

Optimal Design of Irrigation Pipe Network with Multiple Sources

  • Lyu, Heui-Jeong;Ahn, Tae-Jin
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.9-18
    • /
    • 1997
  • Abstract This paper presents a heuristic method for optimal design of water distribution system with multiple sources and potential links. In multiple source pipe network, supply rate at each source node affects the total cost of the system because supply rates are not uniquely determined. The Linear Minimum Cost Flow (LMCF) model may be used to a large scale pipe network with multiple sources to determine supply rate at each source node. In this study the heuristic method based on the LMCF is suggested to determine supply rate at each source node and then to optimize the given layout. The heuristic method in turn perturbs links in the longest path of the network to obtain the supply rates which make the optimal design of the pipe network. Once the best tree network is obtained, the frequency count of reconnecting links by considering link failure is in turn applied to form loop to enhance the reliability of the best tree network. A sample pipe network is employed to test the proposed method. The results show that the proposed method can yield a lower cost design than the LMCF alone and that the proposed method can be efficiently used to design irrigation systems or rural water distribution systems.

  • PDF

A Study on the Optimum Design Flowrate for Tunnel-Type Small Hydro Power Plants

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.81-96
    • /
    • 1992
  • This study represents the methodology for feasibility analysis of small hydro power SHP plant. Cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP candidate site. The perfomance prediction model and construction cost estimation model for tunnel-type SHP plant were developed. Eight tunnel -type SHP candidate sites existing on Han-river were selected and surveyed for actual site reconnaissance. The performance characteristics and economical feasibility for these sites were analyzed by using developed models. As a result, it was found that the optimum design flowrate with the lowest unit generation cost for tunel-type SHP candidate site were the flowrate concerming with between 20% and 30% of time ratio on the flow duration curve. Additionally, primary design specifications such as design flowrate, effective head, capacity, annual averageload factor, annual electricity production were estimated and discussed for eight surveyed SHP candidate sites.

  • PDF

A Study on the Optimum Design Flowrate for Tunnel-Type Small Hydro-Power Plants (터널식 소수력 발전소의 최적 설계유량에 관한 연구)

  • 이철형;박완순
    • Water for future
    • /
    • v.24 no.1
    • /
    • pp.63-71
    • /
    • 1991
  • This study represents the methodology for feasibility analysis of small hydro power plants. Cumulative density function of Weibull distribution and Thi-essen method were adopted to beside flow duration curve at candidate sites. The performance prediction model and construction cost estimation model for tunnel-type small hydro power plants were developed. Eight candidate sites existing on Han river selected and surveyed for actual sites reconnaissance. The performance characteristics and economical feasibility for these sites were analyzed by using developed models. As a result, it was found that the optimum design flowrates with the lowest unit generation cost for tunnel-type small hydro power plants were the flowrate concerning with between 20 % and 30 % of time ratio on the flow duration curve. Additionally, primary design specifications such as design flowrate, effective head, capacity, annual average load factor, annual electricity production were estimated and discussed for surveyed sites.

  • PDF

Modification of TOPMODEL Considering Spatial Connectivity of Saturated Area (공간적 포화면적의 공간적 연결을 고려한 TOPMODEL의 개선과 적용)

  • Kim, Sang-Hyeon;Kim, Gyeong-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.5
    • /
    • pp.515-524
    • /
    • 1999
  • A methodology to resolve a TOPMODEL problem has been suggested, which is associated with the spatial distribution of soil moisture behaviour in a runoff mechanism. A procedure to integrate the spatial information of saturation deficit in the TOPMODEL reflects the connectivity of saturated area in a watershed. The developed algorithm includes an improved basis in tracing the runoff path without increasing the number of parameters. The performance of the developed algorithm has been tested to an upland subwatershed, namely Dongok, which is the IHP watershed located at Wichon, Korea. Comparing with the original statistical version of the TOPMODEL, it has been found that the suggested algorithm can relax an overestimation of peak rate in the runoff simulation.

  • PDF

Spatiotemporal distribution of downscaled hourly precipitation for RCP scenarios over South Korea and its hydrological responses

  • Lee, Taesam;Park, Taewoong;Park, Jaenyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.247-247
    • /
    • 2015
  • Global Climate Model (GCM) is too coarse to apply at a basin scale. The spatial downcsaling is needed to used to permit the assessment of the hydrological changes of a basin. Furthermore, temporal downscaling is required to obtain hourly precipitation to analyze a small or medium basin because only few or several hours are used to determine the peak flows after it rains. In the current study, the spariotemporal distribution of downscaled hourly precipitation for RCP4.5 and RCP8.5 scenarios over South Korea is presented as well as its implications over hydrologica responses. Mean hourly precipitation significantly increases over the southern part of South Korea, especially during the morning time, and its increase becomes lower at later times of day in the RCP8.5 scenario. However, this increase cannot be propagated to the mainland due to the mountainous areas in the southern part of the country. Furthermore, the hydrological responses employing a distributed rainfall-runoff model show that there is a significant increase in the peak flow for the RCP8.5 scenario with a slight decrease for the RCP4.5 scenario. The current study concludes that the employed temporal downscaling method is suitable for obtaining the hourly precipitation data from daily GCM scenarios. In addition, the rainfall runoff simulation through the downscaled hourly precipitation is useful for investigating variations in the hydrological responses as related to future scenarios.

  • PDF

Multidimensional data generation of water distribution systems using adversarially trained autoencoder (적대적 학습 기반 오토인코더(ATAE)를 이용한 다차원 상수도관망 데이터 생성)

  • Kim, Sehyeong;Jun, Sanghoon;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.7
    • /
    • pp.439-449
    • /
    • 2023
  • Recent advancements in data measuring technology have facilitated the installation of various sensors, such as pressure meters and flow meters, to effectively assess the real-time conditions of water distribution systems (WDSs). However, as cities expand extensively, the factors that impact the reliability of measurements have become increasingly diverse. In particular, demand data, one of the most significant hydraulic variable in WDS, is challenging to be measured directly and is prone to missing values, making the development of accurate data generation models more important. Therefore, this paper proposes an adversarially trained autoencoder (ATAE) model based on generative deep learning techniques to accurately estimate demand data in WDSs. The proposed model utilizes two neural networks: a generative network and a discriminative network. The generative network generates demand data using the information provided from the measured pressure data, while the discriminative network evaluates the generated demand outputs and provides feedback to the generator to learn the distinctive features of the data. To validate its performance, the ATAE model is applied to a real distribution system in Austin, Texas, USA. The study analyzes the impact of data uncertainty by calculating the accuracy of ATAE's prediction results for varying levels of uncertainty in the demand and the pressure time series data. Additionally, the model's performance is evaluated by comparing the results for different data collection periods (low, average, and high demand hours) to assess its ability to generate demand data based on water consumption levels.