• Title/Summary/Keyword: the bio current

Search Result 774, Processing Time 0.025 seconds

Schottky barrier poly-Si thin film transistor by using erbium-silicided source and drain (어븀-실리사이드를 이용한 쇼트키 장벽 다결정 실리콘 박막 트랜지스터)

  • Shin, Jin-Wook;Koo, Hyun-Mo;Jung, Myung-Ho;Choi, Chel-Jong;Jung, Won-Jin;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.75-76
    • /
    • 2007
  • Poly-Si Schottky barrier Thin Film Transistor (SB-TFT) is manufactured with erbium silicided source/drain. High quality poly-Si film was obtained by crystallizing the amorphous Si film with Excimer laser annealing (ELA) method. The fabricated poly-Si SB-TFT devices showed low leakage current and large on/off current ratio. Moreover, the electrical characteristics were considerably improved by 3% $H_2/N_2$ gas annealing, which is attributed to the reduction of trap states at the grain boundaries and interface trap states at gate oxide/poly-si channel.

  • PDF

Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge (전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향)

  • Hong, Sung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) process is known to consume enormous energy to control membrane fouling. To solve this problem, electro-coagulation technique has been applied to MBR. A series of electro-coagulation was applied to activated sludge suspension under different current density condition. After the electro-coagulations, membrane filtration of the activated sludge suspensions was conducted to investigate the effect of electro-coagulation on the fouling. As current density increased 10 to 40A/m2, the total fouling resistance (Rc+Rf) decreased from 18 to 79%, showing that the electro-coagulation improved the membrane filtration efficiency. Both the organic concentration in bulk and the particles size distribution were not nearly changed before and after the electro-coagulation. The enhanced filtration efficiency might be due to the aluminum hydroxide generated from chemical precipitation, which can be acted as a dynamic membrane preventing a deposition of foulants on membrane surfaces.

Bio-Jet Fuel Production Technologies for GHG Reduction in Aviation Sector (항공분야 온실가스 감축을 위한 바이오항공유 제조기술)

  • KIM, JAE-KON;PARK, JO YONG;YIM, EUI SOON;MIN, KONG-IL;PARK, CHEON-KYU;HA, JONG-HAN
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.6
    • /
    • pp.609-628
    • /
    • 2015
  • Thie study presents the biomass-derived jet (bio-jet) fuel production technologies for greenhouse gas (GHG) reduction in aviation sector. The aviation sector is responsible for the 2% of the world anthropogenic $CO_2$ emissions and the 10% of the fuel consumption: airlines' costs for fuel reach 30% of operating costs. In addition, the aviation traffic is expected to double within 15 years from 2012, while fuel consumption and $CO_2$ emissions should double in 25 years. Biojet fuels have been claimed to be one of the most promising and strategic solutions to mitigate aviation emissions. This jet fuel, additionally, must meet ASTM International specifications and potentially be a100% drop-in replacement for current petroleum jet fuel. In this study, the current technologies for producing renewable jet fuels, categorized by alcohols-to-jet, oil-to-jet, syngas-to-jet, and sugar-to-jet pathways are reviewed for process, economic analysis and life cycle assessment (LCA) on conversion pathways to bio-jet fuel.

A Tunable Band-Pass Filter for Multi Bio-Signal Detection (대역폭 조정 가능한 다중 생체 신호 처리용 대역 통과 필터 설계)

  • Jeong, Byeong-Ho;Lim, Shin-Il;Woo, Deok-Ha
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • This paper presents a tunable band pass filter (BPF) for multi bio-signal detection. The bandwidth can be controlled by the bias current of transconductance (gm), while conventional BPF exploited switchable capacitor array for band selection. With this design technique, the die area of proposed BPF reduced to at least one tenth the area of conventional design. The simulation results show the high cut-off frequency tuning range of from 100Hz to 1Khz. The circuit was implemented with a 0.18um CMOS standard technology. Total current consumption is 1uA at the supply voltage of 1V with sub-threshold design technique.

Effects or air current speeds on the growth or eggplant plug seedlings in a wind tunnel under artificial lighting (인공광하의 풍동내에서 기류속도가 가지 플러그묘의 생장에 미치는 영향)

  • 김용현
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.9-14
    • /
    • 1998
  • Air current speeds were controlled of 0.3, 0.5, 0.7 and 0.9 m.s$^{-1}$ to investigate the effects of air current speeds on the growth of eggplant plug seedlings (Solanum melongena L.) in a wind tunnel under artificial lighting. Growth of plug seedlings was influenced by the magnitude of air current speed and the traveling distance of regulated air flow. Stem length. ratio of length to diameter in stem, plant height .and number of leaves of plug seedlings decreased with the increasing air current speed and were significantly different at 5% level. Net photosynthetic rates of plug stand increased with the increasing air current speed and took a maximum value at the air current speed of 0.7~09 m.s$^{-1}$ . Stem diameter decreased and leaf area increased with the traveling distance of regulated air flow. Fresh weight and T/R ratio of dried weight were not influenced by the air current speed. Optimum control for microclimates inside the plug stand is needed to produce the uniform growth and high quality of plug seedlings in a semi-closed plant Production system under artificial lighting.

  • PDF

Analog Front-End Circuit Design for Bio-Potential Measurement (생체신호 측정을 위한 아날로그 전단 부 회로 설계)

  • Lim, Shin-Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.130-137
    • /
    • 2013
  • This paper presents analog front-end(AFE) circuits for bio-potential measurement. The proposed AFE is composed of IA(instrument amplifier), BPF(band-pass filter), VGA(variable gain amplifier) and SAR(successive approximation register) type ADC. The low gm(LGM) circuits with current division technique and Miller capacitance with high gain amplifier enable IA to implement on-chip AC-coupling without external passive components. Spilt capacitor array with capacitor division technique and asynchronous control make the 12-b ADC with low power consumption and small die area. The total current consumption of proposed AFE is 6.3uA at 1.8V.

Effect of Potassium Formate, Glycine and Oxalic Acid in Sulfate Bath on Trivalent Chromium Deposition Composition and Current Efficiency (Potassium formate, Glycine, Oxalic acid가 황화물계 3가 크롬도금층의 조성과 전류효율에 미치는 영향)

  • Kim, Man;Kim, Dae-Young;Park, Sang-Eon;Kwon, Sik-Chul;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.86-91
    • /
    • 2004
  • Effect of potassium formate, glycine and oxalic acid in a sulfate solution on the deposit composition and current efficiency of trivalent chromium plating was studied. The trivalent chromium layers prepared by solutions with potassium formate, glycine and oxalic acid contain a few carbon inside. The solutions containing potassium formate, glycine and oxalic acid are relatively stable with pH change. The solution with the potassium formate shows 6-30% current efficiency with current density, whereas, the solutions with oxalic acid and glycine show about 5% current efficiency, respectively. The improved current efficiency is related to enough supply of chromium ions to the electrode due to the increase of pH at the front of electrode.

Appropriate Soil Heat Treatment Promotes Growth and Disease Suppression of Panax notoginseng by Interfering with the Bacterial Community

  • Li, Ying-Bin;Zhang, Zhi-Ping;Yuan, Ye;Huang, Hui-Chuan;Mei, Xin-Yue;Du, Fen;Yang, Min;Liu, Yi-Xiang;Zhu, Shu-Sheng
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.3
    • /
    • pp.294-301
    • /
    • 2022
  • In our greenhouse experiment, soil heat treatment groups (50, 80, and 121℃) significantly promoted growth and disease suppression of Panax notoginseng in consecutively cultivated soil (CCS) samples (p < 0.01), and 80℃ worked better than 50℃ and 121℃ (p < 0.01). Furthermore, we found that heat treatment at 80℃ changes the microbial diversity in CCS, and the inhibition ratios of culturable microorganisms, such as fungi and actinomycetes, were nearly 100%. However, the heat-tolerant bacterial community was preserved. The 16S rRNA gene and internal transcribed spacer (ITS) sequencing analyses indicated that the soil heat treatment had a greater effect on the Chao1 index and Shannon's diversity index of bacteria than fungi, and the relative abundances of Firmicutes and Proteobacteria were significantly higher than without heating (80 and 121℃, p < 0.05). Soil probiotic bacteria, such as Bacillus (67%), Sporosarcina (9%), Paenibacillus (6%), Paenisporosarcina (6%), and Cohnella (4%), remained in the soil after the 80℃ and 121℃ heat treatments. Although steam increased the relative abundances of most of the heat-tolerant microbes before sowing, richness and diversity gradually recovered to the level of CCS, regardless of fungi or bacteria, after replanting. Thus, we added heat-tolerant microbes (such as Bacillus) after steaming, which reduced the relative abundance of pathogens, recruited antagonistic bacteria, and provided a long-term protective effect compared to the steaming and Bacillus alone (p < 0.05). Taken together, the current study provides novel insight into sustainable agriculture in a consecutively cultivated system.

On-chip Magnetic Sensor with Embedded High Inductance Coil for Bio-magnetic Signal Measurement (생체자기 신호측정을 위한 고인덕턴스 코일 내장형 온칩 자기센서)

  • Lyu, HyunJune;Choi, Jun Rim
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.91-98
    • /
    • 2013
  • Magnetic sensor chip for measuring bio-magnetism is implemented in $0.18{\mu}m$ CMOS technology. The magnetic sensor chip consists of a small-sized high inductance coil sensor and an instrumentation amplifier (IA). High inductance coil sensor with suitable sensitivity and bandwidth for measurement of bio-magnetic signal is designed using electromagnetic field simulation. Low gm operational transconductance amplifier (OTA) using transconductance reduction techniques is designed for on-chip solution. Output signal sensitivity of magnetic sensor chip is $3.25fT/{\mu}V$ and reference noise of 21.1fT/${\surd}$Hz. Proposed IA is designed along with band pass filters(BPF) to reduce magnetic signal noise by using current feedback techniques. Proposed IA achieves a common mode rejection ratio of 117.5dB while the input noise referred is kept below $0.87{\mu}V$.

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF