• 제목/요약/키워드: the basic and the modified type

검색결과 130건 처리시간 0.025초

Fabrication and Characterization of Optically Encoded Porous Silicon Smart Particles

  • Sohn, Honglae
    • 통합자연과학논문집
    • /
    • 제7권4호
    • /
    • pp.221-226
    • /
    • 2014
  • Optically encoded porous silicon smart particles were successfully fabricated from the free-standing porous silicon thin films using ultrasono-method. DBR PSi was prepared by an electrochemical etch of heavily doped $p^{{+}{+}}$-type silicon wafer. DBR PSi was prepared by using a periodic pseudo-square wave current. The surface-modified DBR PSi was prepared by either thermal oxidation or thermal hydrosilylation. Free-standing DBR PSi films were generated by lift-off from the silicon wafer substrate using an electropolishing current. Free-standing DBR PSi films were ultrasonicated to create DBR-structured porous smart particles. Optical characteristics of porous smart particles were measured by FT-IR spectroscopy. The surface morphology of porous smart particles was determined by FE-SEM.

한국형 할인점의 서비스품질 측정 척도에 관한 연구 (The Study of Korean -type Discountstore Service Quality Scales(KD-SQS))

  • 노은정;서용구
    • 한국유통학회지:유통연구
    • /
    • 제13권3호
    • /
    • pp.127-154
    • /
    • 2008
  • 본 논문은 고급화된 대형마트 즉 '한국형 할인점'이라는 독특한 업태 컨셉에 보다 적합한 서비스 품질 측정 적도를 연구하는데 그 목적이 있다. 이를 위해 반복적 FGI와 대형 할인점 방문 소비자 604명을 대상으로 정량적 리서치를 실시하였다. 연구 결과 '한국형 할인점'의 서비스 품질은 본원적 혜택, 프로모션, 인적상호작용, 물리적 측면, 정책, 부가적 편의성의 총 6개 차원, 24개 항목으로 이루어진 측정모형이 도출되었다. 기존의 소매 서비스 품질의 대표적 측정 모형인 RSQS 측정모형과 비교해 보면 3가지 자원(인적상호작용, 물리적 측면, 정책)은 공통적이며, 나머지 차원에서 문제해결은 인적상호작용으로 통합되었으며, 신뢰성은 단일차원성이 결여되어 제거되었다. 특히 본원적 혜택은 할인점의 업태특성을 대표하는 성과품질로서 도출되었으며, 정책 자원은 '재방문 의도'에 가장 큰 영향을 미치는 중요한 서비스 품질 자원으로 확인되었다. 본 연구에서 수정, 보완된 측정도구는 한국형 할인점을 이용하는 고객의 최신 트랜드를 반영하여 업버전 하였다는 것이 그 특징이다. 그 결과 향후 소매 시장 포화상황에서 치열한 서비스 경쟁을 벌여야하는 한국의 대형마트와 기타 소매업체에 전략적 시사점을 주고 있다.

  • PDF

농촌지역 소규모 소택형습지의 유형분류 및 기능평가 연구 (The Type Classification and Function Assessment at Small Palustrine Wetland in Rural Areas)

  • 손진관;김남춘;강방훈
    • 한국환경복원기술학회지
    • /
    • 제13권6호
    • /
    • pp.117-131
    • /
    • 2010
  • This study was conducted to utilize as basic information for the construction of conservation and estimation system for Palustrine wetland, which was badly managed and imprudently reclaimed, through the analysis of distribution characteristics and the estimation of conservation value for sample sites (eight wetlands) in rural area. As the result of wetland type classification, these wetlands was classified by 4 types (Permanent freshwater marshes/pools, ponds, Aquaculture ponds, and Seasonally flooded agricultural land) by Ramsar system, 3 types (Emergent Wetland, Aquatic Bed, and Scrub-Shrub Wetland) by NWI (Cowardin) System, 5 types (Farm Pond Depression, Under-flow wetland, Man-made Pond Depression, Abandoned Paddy Fields Wetland, and Reservoir Shore) by National Wetland's Categorical System, and 3 types (Aquatic Bed Wetland, Emergent Wetland, and Forested Wetland) by Lee (2000) System. These results suggest us developing the new type classification system for small Palustrine wetland in Korean rural areas. The score of function assessment (The Modified RAM) for small Palustrine wetlands was high at the wetlands nearby hills and rice paddy fields, and low at those nearby upper fields, which was mainly affected by land-use and vegetation. The functions as 'Flood/Storm Water Storage', 'Runoff Attenuation', 'Water Quality Protection' were resulted by the structural difference of inflow and outlet. Some functions as 'Wetland size', 'Wetland to immediate watershed ratio', 'Presence of boat traffic', 'Maximum water depth', 'Fetch of water's body' of RAM were not appropriate in evaluation of small wetlands in rural area. Which suggest us developing the new function assessment system for small Palustirne wetland in Korean rural areas.

S형 보도사장교의 케이블이 횡방향 거동에 미치는 영향 연구 (Study on the effect of cable on the lateral behavior of S-shaped Pedestrian-CSB)

  • 지선근;임성순
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.577-584
    • /
    • 2019
  • 최근 국내 사장교는 경관적인 요소를 위하여 비정형적인 형태가 시도되고 있다. 새로운 기하구조가 적용된 사장교는 그 특성을 명확히 분석하여 구조안전성을 확보할 필요가 있다. 본 연구 대상 교량은 S자형 곡선 보도사장교로 S자형 평면곡선과 역삼각형트러스 횡단면을 가진 보강거더, 곡선반경 내측에 1면으로 배치된 경사 주탑과 modified Fan 타입 주케이블, 수직 백스테이케이블이 적용되었다. 곡선사장교는 직선사장교와 같이 종방향의 거동에만 초점을 두고 장력을 조정할 경우 횡방향으로 과다한 변위와 모멘트가 발생 할 수 있다. 본 연구는 주케이블이 교량의 횡방향 거동에 미치는 영향을 분석하기 위해서, 장력에 의한 주탑의 횡방향 변위 방향에 따라 케이블을 2개 그룹으로 나누었다. 지간중앙부 케이블 그룹을 GR1, 주탑지점부 케이블 그룹을 GR2라 할 때 GR1과 GR2의 조합비율이 보강거더, 받침, 주탑 그리고 수직앵커케이블에 미치는 영향을 분석하였다. 연구대상 교량에 적용된 장력비율을 1.0GR1+1.0GR2라 하였을 때, 1.2GR1+0.8GR2의 조합에서 주탑지점부 보강거더의 좌측과 우측 상현재 응력이 최소가 되었고, 좌우 부재의 편차도 최소가 되었다. 또한, 받침의 수평력, 주탑의 횡방향 변위와 모멘트, 수직백스테이케이블의 장력도 감소하였다. 본 연구는 유사한 기하구조를 가진 사장교의 장력 결정시 기초 자료로 활용될 것으로 기대된다.

큰느타리버섯 재배사의 구조설계용 자료 분석 (Data Analysis for Structural Design of Pleurotus Eryngii Cultivation Facilities)

  • 서원명;윤용철
    • 한국농공학회논문집
    • /
    • 제47권3호
    • /
    • pp.29-37
    • /
    • 2005
  • This study was carried out to file up structural design data for optimizing Pleurotus eryngii growing houses. Design data are including current farm status of Pleurotus eryngii growing houses in the aspect of structural configuration as well as environmental conditions to be controlled and maintained inside. A structural analysis was performed for the on-farm structures as well as some structures modified and suggested through field survey and analysis. The results are summarized as follows. According to the results of status analysis, Pleurotus eryngii growing houses were categorized as arch-roofed simple type and sandwich panel type. Though the size of Pleurotus eryngii cultivation facilities were considerably diverse, the basic dimensions of Pleurotus eryngii cultivation facilities showed relatively similar pattern: more or less of 20m of length, $6.6\~7.0m$ of width, $4.6\~5.0m$ of peak height, $1.2\~1.6m$ of bed width, and 4 layers of bed. In the aspect of spatial use of cultivation facilities, suggested models were shown to be mostly reasonable in the aspect of heating and cooling, micro-meteorological stability, land use efficiency per unit floor area, etc.. Especially, the standard models suggested so far were thought to be not efficient in its surface area and spatial volume per unit floor area as well as its uneffective structural design in the area around ceiling. In the results of structural analysis for the models suggested through this study by using those section frames to be found on farms, the panel type structures of both single span and double span were estimated to be over designed, whereas arch-roofed pipe houses were mostly found to be under-designed.

Effects of Two Traditional Chinese Cooking Oils, Canola and Pork, on pH and Cholic Acid Content of Faeces and Colon Tumorigenesis in Kunming Mice

  • He, Xiao-Qiong;Duan, Jia-Li;Zhou, Jin;Song, Zhong-Yu;Cichello, Simon Angelo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권15호
    • /
    • pp.6225-6229
    • /
    • 2015
  • Faecal pH and cholate are two important factors that can affect colon tumorigenesis, and can be modified by diet. In this study, the effects of two Chinese traditional cooking oils (pork oil and canola/rapeseed oil) on the pH and the cholic acid content in feces, in addition to colon tumorigenesis, were studied in mice. Kunming mice were randomized into various groups; negative control group (NCG), azoxymethane control group (ACG), pork oil group (POG), and canola oil Ggroup (COG). Mice in the ACG were fed a basic rodent chow; mice in POG and COG were given 10% cooking oil rodent chow with the respective oil type. All mice were given four weekly AOM (azoxymethane) i.p. injections (10mg/kg). The pH and cholic acid of the feces were examined every two weeks. Colon tumors, aberrant crypt foci and organ weights were examined 32 weeks following the final AOM injection. The results showed that canola oil significantly decreased faecal pH in female mice (P<0.05), but had no influence on feces pH in male mice (P>0.05). Pork oil significantly increased the feces pH in both male and female mice (P<0.05). No significant change was found in feces cholic acid content when mice were fed 10% pork oil or canola oil compared with the ACG. Although Kunming mice were not susceptible to AOM-induced tumorigenesis in terms of colon tumor incidence, pork oil significantly increased the ACF number in male mice. Canola oil showed no influence on ACF in either male or female mice. Our results indicate that cooking oil effects faecal pH, but does not affect the faecal cholic acid content and thus AOM-induced colon neoplastic ACF is modified by dietary fat.

6축 휠 동력계의 구조설계 및 평가 (Structural Design and Evaluation of Six-component Wheel Dynamometer)

  • 김만기;주진원
    • 대한기계학회논문집A
    • /
    • 제40권1호
    • /
    • pp.53-63
    • /
    • 2016
  • 자동차 주행 중 도로면으로부터 차량 바퀴에 전달되는 동하중을 측정하기 위해 휠 동력계가 사용된다. 본 논문에서는 전단 변형과 굽힘 변형을 이용한 두 가지 타입의 6축 휠 동력계를 설계하고 비교 평가하였다. 유한요소해석을 이용하여 휠 동력계 기본 구조에 대한 전단 변형 거동과 굽힘 변형 거동을 분석하였으며 이로부터 전단형 휠 동력계와 굽힘형 휠 동력계를 설계하였다. 변형률 해석을 반복 수행하여 각 하중에 대한 출력변형률이 미리 결정된 비슷한 값이 되도록 하고 상호간섭 변형률이 최소화 되도록 설계를 수정하고 브리지 회로를 구성하였다. 전단형 휠 동력계는 균일한 변형률 분포를 얻을 수 있어 제작시 안정된 특성치를 얻을 수 있는 반면에, 굽힘형 휠 동력계는 각 하중에 대한 출력 변형률 값이 더 일정하여 균일한 감도의 좋은 성능을 얻을 수 있을 것으로 예측된다.

S 대역 선형 배열 안테나 급전회로를 위한 저손실, 저부엽 20-출력 스트립라인 전력분배기 (A 20-way Stripline Power Divider for an S band Linear Array Antenna with Low Loss and Low Side Lobe Level)

  • 권태민;김동욱
    • 대한전자공학회논문지TC
    • /
    • 제47권7호
    • /
    • pp.128-134
    • /
    • 2010
  • 본 논문에서는 저부엽과 저손실 특성을 갖는 고전력 20-출력 스트립라인 전력분배기를 설계, 제작하고 측정하였다. 20-출력전력분배기는 S 대역 선형 배열 안테나의 급전회로를 위해 설계되었으며, 좁은 빔폭과 매우 낮은 저부엽 특성을 위해 Dolph-Chebyshev 전류 분포를 활용하였다. 20-출력 전력분배기는 8-출력 분배기 1개, 4-출력 분배기 3개와 링 하이브리드 전력분배기 3개로 구성되었으며, 전력분배의 기본적인 구조로는 T-접합 분배 구조를 사용하였다. 삽입손실과 반사손실을 개선하기 위해서 노치를 T-접합 분배 구조에 적용하였으며 N형 커넥터와 스트립라인 사이의 천이구조를 수정하였다. 설계, 제작된 전력분배기는 대역 내에서 약 0.3 dB의 삽입손실과 8o 보다 작은 rms 위상 부정합 특성을 보였다. 20-출력 전력분배기 2개를 대칭적으로 구성할 경우 40 dB 이상의 저부엽 특성 결과를 20-출력 전력분배기 측정 결과로부터 합성할 수 있었다.

변형된 Elman 신경회로망을 이용한 제어방식 (A Control Method using the modified Elman Neural Network)

  • 최우승;김주동
    • 한국컴퓨터정보학회논문지
    • /
    • 제4권3호
    • /
    • pp.67-72
    • /
    • 1999
  • 신경회로망은 학습능력과 근사화 능력으로 말미암아 패턴인식 및 시스템제어분야에서 많이 사용되고 있으며, 입력층. 출력층. 하나 이상의 은닉층으로 구성된 네드워크이다. Elman 신경회로망은 J. Elman에 의해 제안되었으며. recurrent network의 형태로 구성되어 있다. Elman 신경회로망은 기존의 신경회로망에 context층을 새로 추가하여, 은닉층의 출력을 context층의 입력으로 피드백 하는 구조로 되어 있다. 본 논문에서는 새로운 형태의 Elman 신경회로망을 제안한다. 제안한 방식은 Elman 신경회로망을 변형한 형태로. 은닉층 뿐 만 아니라 출력층의 출력도 context층으로 피드백 하는 형태이다. 제안한 방식의 유용성을 확인하기 위해 multi target system에 적용한다. 시뮬레이션 결과는 제안한 방식이 기존의 신경회로망 및 Elman 신경회로망 보다 우수한 방식임을 보여 주고 있다.

전압 크기의 품질 및 전력수요 변동모델을 고려한 배전계통의 통합적인 신뢰도 및 비용 평가 (Unified Reliability and Its Cost Evaluation in Power Distribution Systems Considering the Voltage Magnitude Quality and Demand Varying Load Model)

  • Yun, Sang-Yun
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.705-712
    • /
    • 2003
  • In this paper, we propose new unified methodologies of reliability and its cost evaluation in power distribution systems. The unified method means that the proposed reliability approaches consider both conventional evaluation factor, i.e. sustained interruptions and additional ones, i.e. momentary interruptions and voltage sags. Because the three voltage quality phenomena generally originate from the outages on distribution systems, the basic and additional reliability indices are summarized considering the fault clearing mechanism. The proposed unified method is divided into the reliability evaluation for calculating the reliability indices and reliability cost evaluation for assessing the damage of customer. The analytic and probabilistic methodologies are presented for each unified reliability and its cost evaluation. The time sequential Monte Carlo technique is used for the probabilistic method. The proposed DVL(Demand Varying Load) model is added to the reliability cost evaluation substituting the average load model. The proposed methods are tested using the modified RBTS(Roy Billinton Test System) form and historical reliability data of KEPCO(Korea Electric Power Corporation) system. The daily load profile of the each customer type in domestic are gathered for the DVL model. Through the case studies, it is verified that the proposed methods can be effectively applied to the distribution systems for more detail reliability assessment than conventional approaches.