• Title/Summary/Keyword: the automatic

Search Result 14,197, Processing Time 0.043 seconds

The Monitoring of Agricultural Environment in Daegwallyeong Area (대관령 지역의 농업환경 모니터링)

  • Park, Kyeong-Hun;Yun, Hye-Jeong;Ryu, Kyoung-Yul;Yun, Jeong-Chul;Lee, Jeong-Ju;Hwang, Hyun-Ah;Kim, Ki-Deog;Jin, Yong-Ik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1027-1034
    • /
    • 2011
  • In order to provide the basic information on the agricultural environment in Daegwallyeong Highland, the characters of weather, water, and soil quality were investigated. The meteorological characteristics was monitored by automatic weather system (AWS) at 17 sites. The quality of water for samples were collected monthly at 24 sites depending on landuse style. Soil samples were collected from a forest, grassland, and the major vegetable cultivation areas such as potato, carrot, Chinese cabbage, onion, head lettuce, and welsh onion field. The weather showed the mountain climate, and the average yearly temperature is $6.4^{\circ}C$, the average temperature in January is $-7.6^{\circ}C$ and the average temperature in July is $19.1^{\circ}C$, and the change of temperature on the districts of Daegwallyeong is severe. The yearly record of precipitation shows 1717.2 mm. The water quality of crop field was worse than forest or grassland in Daewallyeong highland. In 2005, annual T-N, T-P, SS distribution of Chinese cabbage field showed 7.4~11.3, 0.061~0.1, and $3.0{\sim}53.0mg\;L^{-1}$. The potato field showed 3.1~7.2, 0.019~0.056 and $0.5{\sim}3.0mg\;L^{-1}$, respectively. Being compared of water quality between potato field and chinese cabbage field, it showed that the water quality of Chinese cabbage field was worse than potato field. On farming, the soil of crop cultivation showed pH 5.6 to 6.8, $18.0{\sim}42.4g\;kg^{-1}$ of OM, $316{\sim}658mg\;kg^{-1}$ of Avail. $P_2O_5$. The content of cations showed $0.41{\sim}0.88cmol_c\;kg^{-1}$ of Exch. K, $3.73{\sim}7.07cmol_c\;kg^{-1}$ of Exch. Ca and $1.17{\sim}1.90cmol_c\;kg^{-1}$ of Exch. Mg.

Improvement of Oxygen Isotope Analysis in Seawater samples with Stable Isotope Mass Spectrometer (질량분석기를 이용한 해수 중 산소안정동위원소 분석법의 개선)

  • Park, Mi-Kyung;Kang, Dong-Jin;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Oxygen isotope has not been used actively in water mass studies because of difficulties on the analysis though it has advantages as a water mass tracer. The most popular method to analysis the oxygen isotope ratio in water samples is equilibration method: isotopic equilibrium of water with $CO_2$ at constant temperature. The precision of oxygen isotope analysis using commercial automatic $H_2O/CO_2$ equilibrator is ${\pm}0.1%o$. This value is not sufficient for studies in open ocean. The object of this study is to improve the analytical precision enough to apply open ocean studies by modification of the instrument. When sample gas is transferred by the pressure difference, the fractionation which is preferential transportation of light isotope can be occurred since the long transportation path between the equilibrator and mass spectrometer. And the The biggest source of error during the analysis is long distance and large volume of the pathway of sample gas between. Therefore, liquid nitrogen trap and high vacuum system are introduced to the system. The precisions of 14 time analysis of same seawater sample are ${\pm}0.081%o$ and ${\pm}0.021%o$ by built-in system and by modified system in this study, respectively.

Myelin Content in Mild Traumatic Brain Injury Patients with Post-Concussion Syndrome: Quantitative Assessment with a Multidynamic Multiecho Sequence

  • Roh-Eul Yoo;Seung Hong Choi;Sung-Won Youn;Moonjung Hwang;Eunkyung Kim;Byung-Mo Oh;Ji Ye Lee;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Ji-hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.226-236
    • /
    • 2022
  • Objective: This study aimed to explore the myelin volume change in patients with mild traumatic brain injury (mTBI) with post-concussion syndrome (PCS) using a multidynamic multiecho (MDME) sequence and automatic whole-brain segmentation. Materials and Methods: Forty-one consecutive mTBI patients with PCS and 29 controls, who had undergone MRI including the MDME sequence between October 2016 and April 2018, were included. Myelin volume fraction (MVF) maps were derived from the MDME sequence. After three dimensional T1-based brain segmentation, the average MVF was analyzed at the bilateral cerebral white matter (WM), bilateral cerebral gray matter (GM), corpus callosum, and brainstem. The Mann-Whitney U-test was performed to compare MVF and myelin volume between patients with mTBI and controls. Myelin volume was correlated with neuropsychological test scores using the Spearman rank correlation test. Results: The average MVF at the bilateral cerebral WM was lower in mTBI patients with PCS (median [interquartile range], 25.2% [22.6%-26.4%]) than that in controls (26.8% [25.6%-27.8%]) (p = 0.004). The region-of-interest myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (1.87 cm3 [1.70-2.05 cm3] vs. 2.21 cm3 [1.86-3.46 cm3]; p = 0.003) and brainstem (9.98 cm3 [9.45-11.00 cm3] vs. 11.05 cm3 [10.10-11.53 cm3]; p = 0.015). The total myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (0.45 cm3 [0.39-0.48 cm3] vs. 0.48 cm3 [0.45-0.54 cm3]; p = 0.004) and brainstem (1.45 cm3 [1.28-1.59 cm3] vs. 1.54 cm3 [1.42-1.67 cm3]; p = 0.042). No significant correlation was observed between myelin volume parameters and neuropsychological test scores, except for the total myelin volume at the bilateral cerebral WM and verbal learning test (delayed recall) (r = 0.425; p = 0.048). Conclusion: MVF quantified from the MDME sequence was decreased at the bilateral cerebral WM in mTBI patients with PCS. The total myelin volumes at the corpus callosum and brainstem were decreased in mTBI patients with PCS due to atrophic changes.

Distribution characteristics on volatile organic compounds at the forest of Mt. mudeung and downtown (무등산 숲과 도심에서 휘발성유기화합물질의 분포 특성)

  • Lee, Dae-haeng;Park, Kang-soo;Lee, Se-hang;Song, Hyeong-myeong;Lee, Ki-won;Jeong, Hee-yoon;Seo, Gwang-yeob;Cho, Young-gwan;Kim, Eun-sun
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.246-254
    • /
    • 2015
  • From 2013 to 2014, volatile organic compounds (VOCs) were analyzed to determine biogenic volatile organic compounds (BVOCs) and anthropogenic volatile organic compounds (AVOCs) at eight sites in Mt. Mudeung and one site in downtown, by using a GC/Mass-ATD (automatic thermal desorber). The concentration of terpene noted as biogenic volatile organic compounds at Pungamjeong (PA), in a forest of Chamaecyparis obtusa, was 821 pptv, which was the highest among the eight sites. This value was followed by Wonhyogyegok (WH: 785 pptv), Norritzae (NZ, coniferous forest: 679 pptv), Dongjeokgol (DJ, mixed species forest: 513 pptv), Jangbuljae (JB, Abies koreana: 476 pptv), and Seinbongsamgerri (SS, pine trees: 464 pptv). 11~15 species of terpene was detected in the forest depending on the site. At PA in May, α-pinene showed the highest value, occupied 20% of terpene followed by coumarin, sabinene, phellandrene, myrcene, borneol, eucalyptol, β-pinene, cymene, δ-limonene, γ-terpinene, camphor, camphene, and mentol in the order. The mean concentrations of AVOCs were 0.74~2.52 ppbv in the forests and 3.14 ppbv in the downtown area. From May to July, the AVOCs ratios of the downtown to each forest were 1.9~4.0. Among 10 species of AVOCs, the sum of toluene and benzene was 2.34 ppbv and occupied 75%. In June, the ratios of toluene were 44.1% at DJ site and 53.1% at JW site (downtown). The BVOCs showed a positive correlation with the AVOCs at the forest sites (r = 0.328), which was statistically insignificant (p = 0.184).

Comparison of End-to-side and End-to-end Anastomosis in Circular Stapled Gastroduodenostomy (원형 봉합기를 이용한 위십이지장연결술 시 단측연결과 단단연결의 비교)

  • Seo, Min-Woo;Kim, Yong-Jin;Song, Dan;Kang, Gil-Ho;Cho, Gyu-Seok;Lee, Moon-Soo;Hur, Kyung-Yul;Kim, Jae-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: The use of automatic circular staplers for gastroduodenostomy after distal gastrectomy is now widely accepted. We compared the clinical outcomes of two different methods. Materials and Methods: Between March 2005 and February 2008, 134 patients with gastric cancer underwent distal gastrectomies. Seventy-six consecutive patients received end-to-side gastroduodenostomies (ES) between March 2005 and September 2006. The remaining 58 consecutive patients received end-to-end gastroduodenostomies (EE) between November 2006 and February 2008. We analyzed the surgical outcomes between the two groups (ES versus EE) on the basis of prospectively collected data. Results: Among the clinical factors, there were no differences between the two groups. The overall complication rates were 19.7% in the ES group and 13.8% in the EE group (P=0.489). With respect to anastomosis-related complications, 2 cases had bleeding and 2 cases had stenoses in the ES group, while 2 cases in the EE group had bleeding. Re-operation was needed in the case of intraluminal bleeding in the ES group. There were no mortalities in our study. Conclusion: The two methods for gastroduodenostomy were safe and technically feasible. Although there was no statistical difference in the overall complications, including anastomosis-related complications, we demonstrated better outcomes with respect to anastomotic stenosis in the EE group.

  • PDF

Pediatric Endoscopic Sedation in Korea: A Survey of the Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition (소아청소년 진정내시경: 대한소아소화기영양학회 학술위원회 조사 보고)

  • Ryoo, Eell;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Purpose: The aim of this survey was to analyze the choice of sedative drugs and their side effects during pediatric endoscopic sedation in Korea. We also evaluated doctors, caretakers and patient satisfaction with the procedures. Methods: Between June 2006 and July 2006, a 16-item survey regarding current sedation practices, during one month, was mailed to 28 hospitals in Korea. The results of the survey responses were then analyzed. Results: Endoscopy performed under conscious sedation was reported in 89.0% of the responders and endoscopy under general anesthesia in 0.9% of 465 endoscopic procedures. Endoscopy under conscious sedation was performed in 89.1% for upper gastrointestinal endoscopy (GFS) and 88.1% for lower GFS. Midazolam was used for conscious sedation during the endoscopy in 84.5% of cases and propofol was used in two cases (0.5%). In addition, a bezodiazepine/opioid combination was used iin 84.6% (44 cases) for lower GFS. Patients were monitored with pulse oxymetry, EKG (91.4%) as well as automatic BP (5.1%). Transient hypoxia was the only side effect noted and was treated with supplemental oxygen (4.6%). Flumazenil was used in 2.71% of cases. The choice of sedation was made by the endoscopist (84%). The satisfaction rate for endoscopists was 68%, and for the patients and caretakers was 84% (as reported by the endoscopists). Conclusion: Midazolam was used only for the upper GFS and benzodiazepine/opioid combination was used for the lower GFS in Korea. The rate of satisfaction was relatively high and there were no significant side effects noted during the endoscopy under conscious sedation.

  • PDF

A Study of Below Knee Surrounding Dose depends on whether Using Collimator Shielding or not while Percutaneous Coronary Intervention (경피적 관상동맥 중재술 시 차폐 유·무에 따른 슬 하부 주변부 선량에 관한 연구)

  • Park, Jae Jin;Ko, Seong Jin;Kang, Se Sik;Kim, Chang Soo;Kim, Jung Hoon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.353-358
    • /
    • 2013
  • Recently, the Percutaneous Coronary Intervention has become a main treatment for treating Coronary because of increase of Circulatory Disease. Because of this reason, the increase of intervention using radiation causes the radiation exposure to workers. Therefore, the latent radiation injury can be increased. Thus, this study/experiment measured around under knee whether using radiation collimator shielding or not. We measured the exposure does by the experiment methods which are using 60kV, 200mA, and 10ms of Automatic exposure conditions and using the major method of the Cinefluography of Coronary in our hospital. As the result of right coronary artery test cases, LAO $30^{\circ}$ when the curtains if you use lead 98.4%, $Cranial30^{\circ}$ 98.3% have a protective effect of the radiation. left circumflex coronary artery test cases, Caudal $30^{\circ}$ if the shielding effect of 90.2%, Caudal $30^{\circ}LAO$ $30^{\circ}$ 88.7% have a protective effect of the radiation. left anterior descending artery test cases, Cranial $30^{\circ}$ 98.3%, Cranial $30^{\circ}RAO$ $30^{\circ}$ 80.3%, Cranial $30^{\circ}$LAO $30^{\circ}$ 98% of the radiation has a protective effect. OS(Spider view) in the case of test Caudal $40^{\circ}LAO$ $40^{\circ}$ 71.2% appeared to have the effect of radiation shielding. For these reasons, radiation workers need to be aware on taking care of their radiation exposure by using the radiation collimator shielding even though it is uncomfortable for them.

Impacts of Three-dimensional Land Cover on Urban Air Temperatures (도시기온에 작용하는 입체적 토지피복의 영향)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The purpose of this study is to analyze the impacts of three-dimensional land cover on changing urban air temperatures and to explore some strategies of urban landscaping towards mitigation of heat build-up. This study located study spaces within a diameter of 300m around 24 Automatic Weather Stations(AWS) in Seoul, and collected data of diverse variables which could affect summer energy budgets and air temperatures. The study also selected reflecting study objectives 6 smaller-scale spaces with a diameter of 30m in Chuncheon, and measured summer air temperatures and three-dimensional land cover to compare their relationships with results from Seoul's AWS. Linear regression models derived from data of Seoul's AWS revealed that vegetation volume, greenspace area, building volume, building area, population density, and pavement area contributed to a statistically significant change in summer air temperatures. Of these variables, vegetation and building volume indicated the highest accountability for total variability of changes in the air temperatures. Multiple regression models derived from combinations of the significant variables also showed that both vegetation and building volume generated a model with the best fitness. Based on this multiple regression model, a 10% increase of vegetation volume decreased the air temperatures by approximately 0.14%, while a 10% increase of building volume raised them by 0.26%. Relationships between Chuncheon's summer air temperatures and land cover distribution for the smaller-scale spaces also disclosed that the air temperatures were negatively correlated to vegetation volume and greenspace area, while they were positively correlated to hardscape area. Similarly to the case of Seoul's AWS, the air temperatures for the smaller-scale spaces decreased by 0.32% ($0.08^{\circ}C$) as vegetation volume increased by 10%, based on the most appropriate linear model. Thus, urban landscaping for the reduction of summer air temperatures requires strategies to improve vegetation volume and simultaneously to decrease building volume. For Seoul's AWS, the impact of building volume on changing the air temperatures was about 2 times greater than that of vegetation volume. Wall and rooftop greening for shading and evapotranspiration is suggested to control atmospheric heating by three-dimensional building surfaces, enlarging vegetation volume through multilayered plantings on soil surfaces.

Utilization of Smart Farms in Open-field Agriculture Based on Digital Twin (디지털 트윈 기반 노지스마트팜 활용방안)

  • Kim, Sukgu
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2023.04a
    • /
    • pp.7-7
    • /
    • 2023
  • Currently, the main technologies of various fourth industries are big data, the Internet of Things, artificial intelligence, blockchain, mixed reality (MR), and drones. In particular, "digital twin," which has recently become a global technological trend, is a concept of a virtual model that is expressed equally in physical objects and computers. By creating and simulating a Digital twin of software-virtualized assets instead of real physical assets, accurate information about the characteristics of real farming (current state, agricultural productivity, agricultural work scenarios, etc.) can be obtained. This study aims to streamline agricultural work through automatic water management, remote growth forecasting, drone control, and pest forecasting through the operation of an integrated control system by constructing digital twin data on the main production area of the nojinot industry and designing and building a smart farm complex. In addition, it aims to distribute digital environmental control agriculture in Korea that can reduce labor and improve crop productivity by minimizing environmental load through the use of appropriate amounts of fertilizers and pesticides through big data analysis. These open-field agricultural technologies can reduce labor through digital farming and cultivation management, optimize water use and prevent soil pollution in preparation for climate change, and quantitative growth management of open-field crops by securing digital data for the national cultivation environment. It is also a way to directly implement carbon-neutral RED++ activities by improving agricultural productivity. The analysis and prediction of growth status through the acquisition of the acquired high-precision and high-definition image-based crop growth data are very effective in digital farming work management. The Southern Crop Department of the National Institute of Food Science conducted research and development on various types of open-field agricultural smart farms such as underground point and underground drainage. In particular, from this year, commercialization is underway in earnest through the establishment of smart farm facilities and technology distribution for agricultural technology complexes across the country. In this study, we would like to describe the case of establishing the agricultural field that combines digital twin technology and open-field agricultural smart farm technology and future utilization plans.

  • PDF

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.