• Title/Summary/Keyword: the Unit

Search Result 29,213, Processing Time 0.06 seconds

A Study on the Cooling Load of South and East Facing Apartment Houses (남향과 동향 집합주택의 냉방부하에 관한 연구)

  • 박근우;이경희
    • Journal of the Korean housing association
    • /
    • v.11 no.2
    • /
    • pp.129-137
    • /
    • 2000
  • This study is about the difference of South and East facing Cooling load of Apartment s Houses using Dynamic Heat-flow Calculation. Therefore, the purpose of this study is come in to use Material for the Thermal Environments of Apartment Houses. The results of the analysis are below. (1) For the peak load of degree hour; The highest is "I" unit and the next high load is H, F, E, C, B, G, D and A unit for the south facing Apartment houses. The higher load is "H" unit and the next high load is I, E, F, B, C, G, D, A Unit for the east facing Apartment houses. (2) For the total load of degree day; The highest load is "I" unit and the next high load is H, G, F, E, C, B, D and A Unit for the south facing Apartment houses. The highest load is "H" unit and the next high load is I, G, E, F, B, C, D, A Unit for the east facing Apartment houses. (3) For the total load of degree day; The highest load is "H" Unit for the east facing Apartment houses and the Lowest load is "A" Unit for the south facing Apartment houses.is "A" Unit for the south facing Apartment houses.nt houses.

  • PDF

A Study on the Derivation of the Unit Hydrograph using Multiple Regression Model (다중회귀모형으로 추정된 모수에 의한 최적단위유량도의 유도에 관한 연구)

  • 이종남;김채원;황창현
    • Water for future
    • /
    • v.25 no.1
    • /
    • pp.93-100
    • /
    • 1992
  • A study on the Derivation of the Unit Hydrograph using Multiple Regression Moe이. The purpose of this study is to deriver an optimal unit hydrograph suing the multiple regression model, particularly when only small amount of data is available. The presence of multicollinearity among the input data can cause serious oscillations in the derivation of the unit hydrograph. In this case, the oscillations in the unit hydrograph ordinate are eliminated by combining the data. The data used in this study are based upon the collection and arrangement of rainfall-runoff data(1977-1989) at the Soyang-river Dam site. When the matrix X is the rainfall series, the condition number and the reciprocal of the minimum eigenvalue of XTX are calculated by the Jacobi an method, and are compared with the oscillation in the unit hydrograph. The optimal unit hydrograph is derived by combining the numerous rainfall-runoff data. The conclusions are as follows; 1)The oscillations in the derived unit hydrograph are reduced by combining the data from each flood event. 2) The reciprocals of the minimum eigen\value of XTX, 1/k and the condition number CN are increased when the oscillations are active in the derived unit hydrograph. 3)The parameter estimates are validated by extending the model to the Soyang river Dam site with elimination of the autocorrelation in the disturbances. Finally, this paper illustrates the application of the multiple regression model to drive an optimal unit hydrograph dealing with the multicollinearity and the autocorrelation which cause some problems.

  • PDF

Study of Improved Transporting Methods on Unit Module (유닛모듈 운송 방법의 개선방향 연구)

  • Park, Su-Yeul;Kim, Kyoon-Tai;Park, Nam-Cheon;Jung, In-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.243-244
    • /
    • 2012
  • Recently, research has been actively conducted for getting interested in unit module housing. However, the domestic unit modular housing research in the early stages yet, so the major process for research is lacking. Explore all these reasons fit with domestic unit housing development this paper, focusing on the process of shipping cargo by truck, transport unit module was studied. The purpose of this paper is to present new ideas and derive the direction of the development of the equipment safely and effectively fixed to the unit module of the transport unit module that will be helpful in the development of the equipment required for the transport process of the next unit module.

  • PDF

Analysis of Population Depending on Spatial Unit for Setting Suitable Spatial Unit to Rural Planning (농촌계획 수립에 적합한 공간단위 설정을 위한 공간 단위에 따른 인구 비교 분석)

  • Lee, Jimin
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.3
    • /
    • pp.1-9
    • /
    • 2019
  • Population is important as a fundamental element of local industry and economy, and census data is essential to regional planning and policy making. Although there have been many researches on population and regional planning, there are few studies on population considering spatial unit. In this study, the population of three spatial scales were compared in order to establish the spatial unit suitable for the rural planning. The study area is Gangwon, Chungcheong-Nam, Chungcheong-Buk, Jeolla-Nam, Jeolla-Buk, Gyeonsang-Nam, Gyeonsang-Buk and Jeju province. Population were compared using statistical data analysis, GIS visualization, and spatial statistics. The mean, maximum, minimum, and variance of population were calculated and the coefficient of variation according to spatial unit was compared. The mean, maximum, minimum, and variance of population were calculated and the coefficient of variation according to spatial unit was compared. As the results, the census output area unit is difficult to interpret spatial analysis results. Administrative district unit has the limit that includes areas where the population does not live. The grid unit is well suited to the geographical characteristics but has many disadvantages of the grid with small population. Therefore, It is necessary to complement the limits of the Eup and Myeon-dong administrative district through the grid unit data.

A Study on the Plan Formation of University Dormitory's Living Unit by Modular Unit (모듈러 유닛에 의한 대학 기숙사 단위 생활공간의 평면 구성에 대한 고찰)

  • Kim, Jung-Heon;Kim, Jin-Mo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.2
    • /
    • pp.37-45
    • /
    • 2009
  • The purpose of this study is to suggest the plan formation for university dormitory's living unit by the modular unit of the pre-fabricated architecture, Pursuing this, this study conducts the investigation of present domestic situation of prefabricated construction and practices plan formation for living unit concentrating on the dweller's satisfaction by solving the problems which hitherto constructed dormitory had, especially collapse of dweller's territoriality. Consequently, this study presents the feasibility of modular unit of present prefabricated construction as a new method of dormitory's living unit construction, and suggests the pertinent plan formation for the improvement of the dweller's territoriality.

A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit (실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

Review on Application Tolerance of Unit Hydrograph for Calculating Flood Runoff Hydrograph (홍수 유출 수문곡선 산출에 단위유량도 적용 오차의 정도 검토)

  • Yoo, Ju-Hwan;Yoon, Yeo-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.346-349
    • /
    • 2010
  • In this study several unit hydrographs by rainfall storms are derived and moving averaged unit hydrograph is extracted from them based on the rainfall-runoff data in a small basin 8.5 $km^2$ wide. And peak discharges and peak times of the unit hydrographs are investigated and reviewed. And then a representative unit hydrograph of the moving averaged one is applied to the linear convolution integration for obtaining the flood discharge hydrograph and peak discharge and time of its result are researched and inspected. Variance in application of the representative unit hydrograph in a basin on assumption of linearity is appeared and this is given as a counterevidence about that the runoff response from rainfall on a basin has nonlinear characteristics. And As a result of application of derived representative unit hydrograph the errors in peak discharge and time are investigated.

  • PDF

Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin (낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석)

  • Lee, Hongshin;Son, Gontae;Gu, Jungeun;Konboonraksa T.;Lee, Hongtae;Lee, Seunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

Comparison of Estimation Method of Pollutant Unit Loads from Bridge Area (교량지역의 다양한 비점오염물질 원단위 산정방법 비교)

  • Kim, Taewon;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.597-604
    • /
    • 2011
  • This research analyzed the runoff patterns and estimated unit loads of selected pollutatnts using monitored data conducted for three years in a bridge area. Three estimating methods; the arithmetic average method, the regression method and the rainfall class method were used to estimate the unit load. Results of three estimating methods were compared with the unit pollutant loads from landuses in Korea and the unit pollutant loads from urban watersheds in Milwaukee, USA. Unit load using the arithmetic mean method were found to be overestimated. In terms of TSS, unit loads of two estimate were half lower than that of USA. Estimated TN and TP unit loads of three estimate were lower than that of Ministry of Environment in Korea.

Blazed $GxL^{TM}$ Device for Laser Dream Theater at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nishida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.556-559
    • /
    • 2006
  • We successfully developed a high performance and highly reliable blazed GxL device with a high optical efficiency and a high contrast ratio. The device demonstrated superior resistance against a high power laser, which is suitable for a large-area laser projector. We operated the world's largest laser projection screen using this device at the 2005 World Exposition in Aichi, Japan, problem free.

  • PDF