• Title/Summary/Keyword: the Unit

Search Result 29,213, Processing Time 0.061 seconds

Mineralogical and Geochemical Properties and Origin of Clay-silt Sediments, Suwon, Korea (경기도 수원시에서 산출되는 적갈색 점토-실트 퇴적물의 광물 및 지화학 특성과 기원)

  • Jeong, Gi Young
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.3
    • /
    • pp.153-163
    • /
    • 2020
  • Mineral and geochemical analysis were conducted on two sections (~3.5 m) of red-brown claysilt sediments covering the gneiss and granite weathering zones in Suwon-si for establishing Quaternary paleoenvironmental changes in Korea. The sections were divided into four sedimentary layers (Unit 1-4) by vertical changes in mineral composition and chemical composition. The lowermost unit 1 was a sandy sediment with a high K-feldspar content with a significant contribution of weathered bedrock. Unit 2 was a transition layer showing intermediate characteristics. Unit 3 was a reddish brown clay-silt sediment, with a total clay content of 58% on average, and the main clay minerals were illite-smectite mixed layer minerals and hydroxy-interlayered vermiculite/smectite. Unit 3 contained almost no plagioclase, while the content of kaolin minerals derived by the plagioclase weathering was higher than in the other layers. Unit 4 had similar mineral composition and chemical properties to Unit 3, but had a higher content of plagioclase and chlorite and lower content of kaolin minerals. The chemical compositions of the sections were compared with those in other regions of Korea, suggesting the eolian origin of Units 3 and 4. The paleoenvironmental change in the sedimentary section of this region was interpreted as follows. Weathered products of gneiss and granite, which are bedrocks of this region, were eroded and deposited as sandy sediments in the periphery to form the lower layers (Unit 1, 2), followed by the deposition of the claysilty rich eolian sediments (Unit 3) during the glacial. Unit 3 was chemically weathered during the warm humid climate during the last interglacial, developing a reddish brown color. After that, a eolian sediment layer (Unit 4) was deposited during the last glacial.

Development and Evaluation of Fixation Equipment for Transporting Unit Modules

  • Park, Su-Yeul;Kim, Kyoon-Tai;Park, Nam-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.609-618
    • /
    • 2013
  • The unit modular construction system is a building technique in which unit modules are manufactured at a factory and then assembled at the construction site. It has many benefits, including reduction of the construction period and improvement in quality. For this reason, it is utilized for various purposes in Japan and England. While it has been introduced in Korea, there have been few Korean studies conducted on the unit modular system. In particular, little research has been done on the method of safely fixating the unit modules to a truck. Therefore, this study reviewed the fixation methods of unit modules for transport, analyzed the problems, and designed a fixation device for unit modules. In addition, a device for the fixation of unit modules to a truck was developed, and a structural simulation was implemented for a safety test by considering the maximum stress generated during the transport of the unit modules fixed on a truck. When the device for the fixation of unit modules is manufactured based on the results of the structural simulation done in this study, it is expected to aid the development of a more practical fixation device for unit modules.

A Study on the Homemakers' Housing Notion according to Unit Size in Apartment - focus on 20pyung∼50pyung - (공동주택 평형별 주부들의 주거관에 관한 조사연구 - 20평형대∼50평형대를 중심으로 -)

  • 장경수;김경순
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.116-124
    • /
    • 2003
  • The purpose of this study was provide basic data for homemakers' housing notion according to unit size in apartment. This study was conducted by questionnaires that concerning about middle class homemakers whom they lived in Bundang. The results of this study were as follows; 1) In research on the homemakers' general quality, 20pyung unit size was alike 30pyung unit size and 40pyung unit size was similar to 50pyung unit size. 2) Homemakers' perception according to unit size in apartment was various; (a) 20pyungㆍ30pyung unit size-effective household space for husbands' participation, more sports facilities, parking lot space etc. (b) 40pyungㆍ50pyung unit size-homemakers' individual room, ordering and variable unit plan etc. 3) In research on the homemakers' needs, each of unit size was analogous to storage, common facility, new design and new housing form etc.

Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses (공동주택 단위난방부하 계산을 위한 단위동법 제안)

  • Yoo Ho-Seon;Chung Joo-Hyuk;Moon Jung -Hwan;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

Human and organizational factors for multi-unit probabilistic safety assessment: Identification and characterization for the Korean case

  • Arigi, Awwal Mohammed;Kim, Gangmin;Park, Jooyoung;Kim, Jonghyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.104-115
    • /
    • 2019
  • Since the Fukushima Daiichi accident, there has been an emphasis on the risk resulting from multi-unit accidents. Human reliability analysis (HRA) is one of the important issues in multi-unit probabilistic safety assessment (MUPSA). Hence, there is a need to properly identify all the human and organizational factors relevant to a multi-unit incident scenario in a nuclear power plant (NPP). This study identifies and categorizes the human and organizational factors relevant to a multi-unit incident scenario of NPPs based on a review of relevant literature. These factors are then analyzed to ascertain all possible unit-to-unit interactions that need to be considered in the multi-unit HRA and the pattern of interactions. The human and organizational factors are classified into five categories: organization, work device, task, performance shaping factors, and environmental factors. The identification and classification of these factors will significantly contribute to the development of adequate strategies and guidelines for managing multi-unit accidents. This study is a necessary initial step in developing an effective HRA method for multiple NPP units in a site.

A Derivation of a Hydrograph by Using Smoothed Dimensionless Unit Kernel Function (평활화된 무차원 단위핵함수를 이용한 단위도의 유도)

  • Seong, Kee-Won
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.6
    • /
    • pp.559-564
    • /
    • 2008
  • A practical method is derived for determining the unit hydrograph and S-curve from complex storm events by using a smoothed unit kernel approach. The using a unit kernel yields more convenient way of constructing a unit hydrograph and its S-curve than a conventional method. However, with use of real data, the unit kernel oscillates and is unstable so that a unit hydrograph and S-curve cannot easily obtained. The use of non-parametric ridge regression with a Laplacian matrix is suggested for deriving an event averaged unit kernel which reduces the computational efforts when dealing with the Nash instantaneous unit hydrograph as a basis of the kernel. A method changing the unit hydrograph duration is also presented. The procedure shown in this work will play an efficient role when any unit hydrograph works is involved.

An Analysis of Call Demands of Two Squads In Kyonggi Provincial fire and Disaster Headquarters (경기도 소방재난본부에 소속된 두 구급대의 출동수요 분석)

  • Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • The purposes of this research which was conducted by surveying lost/added unit hours reports, unit hour demand analysis worksheets from prehospital care reports of two squads in Kyonggi Provincial Fire and Disaster Headquarters for 20 weeks (January 1, 2002 - May 20, 2002) are to get Unit Hour Utilizations. Call Demands such as Unit Hour Demand, Simple Average Demand, High Average Demand, Peak Average Demand, the High Actual Demand. The conclusions from this analysis were summarized as follows: (1) By revealing Unit Hour Produced 3223.9, Call Volume 964, Unit Hour Utilization 0.299 at the Squad A and Unit Hour Produced 3328.4, Call Volume 901, Unit Hour Utilization 0.271 at the Squad B induced Korean Squads to chance identification, definition, direction of Unit Hour Utilization. (2) By revealing Simple Average Demand 7.4 on Monday Tuesday, High Average Demand 9.6 on Tuesday Friday. Peak Average Demand 11.5 on Tuesday, the High Actual Demand 12 on Tuesday Wednesday at the Squad A and Simple Average Demand 6.8 on Sunday, High Average Demand 10.4 on Monday, Peak Average Demand 11.5 on Monday, the High Actual Demand 13 on Monday at the Squad B enabled Korean Squads to utilize System Status Management. (3) The Maximum Calls per Unit Hour were 115 for 23:00~23:59, the Minimum Calls per Unit Hour were 46 for 05:00~05:49 in two squads. The Maximum Calls per Unit Hour were 7.4 on Tuesday Saturday, the Minimum Calls per Unit Hour were 6.1 on Thursday at the Squad A. The Maximum Calls per Unit Hour were 7.3 on Monday Saturday, the Minimum Calls per Unit Hour were 5.6 on Thursday at the Squad B. (4) Analyzing demand for EMTs in the optimum emergency medical service of Korea, we have been able to utilize this Unit Hour Utilization in company with the established estimation methods such as international comparisons or the number of ambulances for scientific reasonable estimation. (5) These Call Demands which were limited to the demand time in this study will make us expect some following studies including demand time, demand time, demand map for Strategic Deployment.

  • PDF

Design of a Dispatch Unit & Operand Selection Unit for Improving the SIMT Based GP-GPU Instruction Performance (SIMT구조 GP-GPU의 명령어 처리 성능 향상을 위한 Dispatch Unit과 Operand Selection Unit설계)

  • Kwak, Jae Chang
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.455-459
    • /
    • 2015
  • This paper proposes a dispatch unit of GP-GPU with SIMT architecture to support the acceleration of general-purpose operation as well as graphics processing. If all the information of an operand used instructions issued from the warp scheduler is decoded, an unnecessary operand load occurs, resulting in register loads. To resolve this problem, this paper proposes a method that can reduce the operand load and the load on the resister by decoding only the information of the operand using a pre-decoding method. The operand information from the dispatch unit is passed to the operand selection unit with preventing register bank collisions. Thus the overall performance are improved. In the simulation test, the total clock cycles required by processing 10,000 arbitrary instructions issued from the wrap scheduler using ModelSim SE 10.0b are measured. It shows that the application of the dispatch unit equipped with the pre-decoding function proposed in this paper can make an improvement of about 12% in processing performance compared to the conventional method.

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.

Analysis and Design of Low Pass Filter using Unit Cell based on CRLH Transmission Line

  • Yang, Lei;Yang, Doo-Yeong
    • International Journal of Contents
    • /
    • v.8 no.3
    • /
    • pp.100-104
    • /
    • 2012
  • In this paper, a unit cell for low pass filter design by using composite right and left-handed transmission line in conductor-backed coplanar waveguide is proposed. The characteristics of the unit cell are analyzed in order to design a low pass filter in small sizes. By changing the sizes of the unit cell, the parameters of right-handed and left-handed immittance components are changed and the desired characteristics of the unit cell are achieved. The equivalent circuit of the unit cell is extracted and analyzed either. As a result, the simulation results of the unit cell and the equivalent circuit are almost identified. The movement and energy distributions of electromagnetic field are shown to confirm the property of the unit cell. In the end, a low pass filter is demonstrated by cascading three proposed unit cells, which shows cutoff frequency of 1.53GHz and deep attenuation from 2.23GHz to 4.49GHz lower than -50dB.