• Title/Summary/Keyword: testing and evaluating

Search Result 550, Processing Time 0.027 seconds

Evaluating the Accuracy of Blood Pressure Measurement (혈압측정의 정확성 평가)

  • Cho, Sung-Hyun;Hwang, Jeong-Hae;Kim, Eun-Gyung;Oh, Byung-Hee;Kim, Chang-Yup
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF

Development of Quantitative Methods for Evaluating Failure Safety of Level 3 Autonomous Vehicles (SAE Level 3 자율주행자동차의 고장 안전성 정량적 평가 방법 개발에 관한 연구)

  • Kim, Dooyong;Lee, Sangyeop;Lee, Hyuckkee;Choi, Inseong;Shin, Jaekon;Park, Kihong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.1
    • /
    • pp.91-102
    • /
    • 2019
  • Autonomous vehicles can be exposed to severe danger when failure occurs in any of its components. For this reason many countries are making efforts on the legislative issue how to objectively evaluate failure safety of an autonomous vehicle when such a vehicle is commercially available to a customer in the near future. In level-3 automation, a driver must take over the control of his vehicle when failure occurs, and the driver's controllability must be secured for escape from the imminent danger. In this paper, quantitative methods have been developed for evaluating failure safety of the level-3 autonomous vehicle, and they were validated by simulation. And also, we confirmed that the proposed evaluation method can quantitatively evaluate the failure safety.

Effects of Students' Prior Knowledge on Scientific Reasoning in Density (학생들의 사전 지식이 밀도과제의 과학적 추론에 미치는 영향)

  • Yang, II-Ho;Kwon, Yong-Ju;Kim, Young-Shin;Jang, Myoung-Duk;Jeong, Jin-Woo;Park, Kuk-Tae
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.2
    • /
    • pp.314-335
    • /
    • 2002
  • The purpose of this study was to investigate the effects of students' prior knowledge on scientific reasoning process performing a task of controlling variables with computer simulation and to identify a number of problems that students encounter in scientific discovery. Subjects for this study included 60 Korean students: 27 fifth-grade students from an elementary school; 33 seventh-grade students from a middle school. The sinking objects task involving multivariable causal inference was used. The task was presented as computer simulation. The fifth and seventh-grade students participated individually. A subject was interviewed individually while the investigating a scientific reasoning task. Interviews were videotaped for subsequent analysis. The results of this study indicated that students' prior knowledge had a strong effect on students' experimental intent; the majority of participants focused largely on demonstrating their prior knowledge or their current hypothesis. In addition, studnets' theories that were part of one's prior knowledge had significant impact on formulating hypotheses, testing hypothesis, evaluating evidence, and revising hypothesis. This study suggested that students' performance was characterized by tendencies to generate uninformative experiments, to make conclusion based on inconclusive or insufficient evidence, to ignore, reject, or reinterpret data inconsistent with their prior knowledge, to focus on causal factors and ignore noncausal factors, to have difficulty disconfirming prior knowledge, to have confirmation bias and inference bias (anchoring bias).

An Effectiveness Verification for Evaluating the Amount of WTCI Tongue Coating Using Deep Learning (딥러닝을 이용한 WTCI 설태량 평가를 위한 유효성 검증)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.226-231
    • /
    • 2019
  • A WTCI is an important criteria for evaluating an mount of patient's tongue coating in tongue diagnosis. However, Previous WTCI tongue coating evaluation methods is a most of quantitatively measuring ration of the extracted tongue coating region and tongue body region, which has a non-objective measurement problem occurring by exposure conditions of tongue image or the recognition performance of tongue coating. Therefore, a WTCI based on deep learning is proposed for classifying an amount of tonger coating in this paper. This is applying the AI deep learning method using big data. to WTCI for evaluating an amount of tonger coating. In order to verify the effectiveness performance of the deep learning in tongue coating evaluating method, we classify the 3 types class(no coating, some coating, intense coating) of an amount of tongue coating by using CNN model. As a results by testing a building the tongue coating sample images for learning and verification of CNN model, proposed method is showed 96.7% with respect to the accuracy of classifying an amount of tongue coating.

A Study on the Development of Soil-based PTMs for Analysis of BTEX (BTEX 분석용 토양 숙련도 표준시료(PTMs) 개발에 관한 연구)

  • Lee, Minhyo;Lee, Guntaek;Lee, Bupyoel;Lee, Wonseok;Kim, Gumhee;Hong, Sukyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.15-25
    • /
    • 2013
  • In this study, two kinds of soil-based proficiency testing materials (PTMs), NICE-012L and NICE-012R were prepared and certified for Benzen, Toluene, Etylbenzene and Xylene with evaluation of uncertainties. In order to analyse BTEX (Benzen Toluene Etylbenzene Xylene) for the candidate materials, GC/MS was used after pretreatment according to methods of soil analysis by Ministry of Environment. For the homogeneity test among bottles in terms of candidate materials, ISO 13528 and IUPAC Protocol were used and according to the result, both candidate materials showed sufficient homogeneity. Also, the stability test over the candidate materials was accessed according to the ISO Guide 35 by classifying short-term and long-term stability and the result showed that both candidate materials showed decent stability. The reference values of the two candidate materials depending on BTEX components were derived from the average of the 11 samples that were used for verification of the samples' homogeneity. Uncertainty of measurement was combined by uchar that was caused by a characteristic value, $u_{bb}$ that was caused by between-bottle homogeneity, and $u_{stab}$ that was caused by stability, and then combined uncertainty ($u_{PTM}$) was multiplied to the coverage factor (k) derived from the effective degree of freedom from each factor that leads to expanded uncertainty (U) in about 95% of confidence level. The proficiency testing materials developed through this study were supplied to National Institute of Environmental Research (NIER) and utilized as an external proficiency testing materials for evaluating analysis capacity of soil agencies with specialty in terms of soil analysis approved by Minister of Environment.

A real-time hybrid testing based on restart-loading technology for viscous damper

  • Guoshan Xu;Lichang Zheng;Bin Wu;Zhuangzhuang Ji;Zhen Wang;Ge Yang
    • Smart Structures and Systems
    • /
    • v.32 no.6
    • /
    • pp.349-358
    • /
    • 2023
  • Real-Time Hybrid Testing (RTHT) requires the numerical substructure calculations to be completed within the defined integration time interval due to its real-time loading demands. For solving the problem, A Real-Time Hybrid Testing based on Restart-Loading Technology (RTHT-RLT) is proposed in this paper. In the proposed method, in case of the numerical substructure calculations cannot be completed within the defined integration time interval, the experimental substructure was returned back to the initial state statically. When the newest loading commands were calculated by the numerical substructure, the experimental substructure was restarted loading from the initial state to the newest loading commands so as to precisely disclosing the dynamic performance of the experimental substructure. Firstly, the methodology of the RTHT-RLT is proposed. Furthermore, the numerical simulations and experimental tests on one frame structure with a viscous damper are conducted for evaluating the feasibility and effectiveness of the proposed RTHT-RLT. It is shown that the proposed RTHT-RLT innovatively renders the nonreal-time refined calculation of the numerical substructure feasible for the RTHT. The numerical and experimental results show that the proposed RTHT-RLT exhibits excellent performance in terms of stability and accuracy. The proposed RTHT-RLT may have broad application prospects for precisely investigating the dynamic behavior of large and complex engineering structures with specific experimental substructure where a restarting procedure does not affect the relevant hysteretic response.

Developing and Evaluating a Drug Information Leaflet of Antidiabetics for Senior Citizens; Employing Performance-based User-testing (노인용 당뇨치료제 안전사용설명서 개발 및 평가: 수행능력 기반 사용자 평가 활용)

  • Kim, Jin;Shim, Haeri;Lee, Iyn-Hyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.27 no.3
    • /
    • pp.171-177
    • /
    • 2017
  • Objective: The study purpose was to develop a drug information leaflet for the elderly and to evaluate it with performance-based user-testing. Methods: We performed a stratified randomized controlled trial. We recruited 62 elderly patients with age of 65 or above who were taking antidiabetic medications at the point of participating and excluded those who suffered illiteracy. We randomly allocated them into the intervention group with a leaflet for the elderly and the control group with a leaflet for the general public. Main outcome measures were to 'be able to find information' and to 'be able to understand information.' We measured outcome variables by employing performance-based user-testing and analyzed data to find any differences between two groups with t-tests, chi-squared tests or Fisher's exact tests accordingly. Results: More participants in the intervention group understood how to store their medications than those in the control group (intervention group 93% vs. control group 70%; p=0.02). There were no significant differences in other information items between two groups. Mostly 'being able to understand information' was lower than 'being able to find information.' The gaps between two outcome variables were about 10% in the intervention group and about 18% in the control group. The lowest understanding was observed in information relating to drug names and their potential adverse events. Conclusion: Without providing personalized drug information, it might be hard for the elderly to improve their drug knowledge even with leaflets that were developed specifically for the elderly.

A study on development of CRM chrysotile in soil (토양 중 백석면 표준물질 개발에 관한 연구)

  • Choi, Yun-Ho;Kwon, Ye-Bin;Lee, Jin-Wook;Kim, Nam-Jun;Jeong, Min-Jong;Hwang, Beom-Goo;Lee, Jae-Hyung;Sun, Yle-Shik;Kim, Bak-Gil
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • Interested in NOA (Naturally Occurring Asbestos), Korea as well as the USA has been making geologic maps of asbestos distributed mines and surrounding areas, restoring mines, evaluating hazard, and so on. The result can be used to improve the reliability of analysts and analysis institutions by judging the amount of asbestos and set up PLM(Polarizing Light Microscope) information by analyzing in soil. The certification value of 2 kinds of CRM(Certified Reference Material) was performed by counting total 400 points with EPA 600-R-93-116 method using by PLM. The following is the result of homogeneity and stability of 2 kinds of manufactured CRM analyzed by ANOVA (Analysis of variance) and Regression Analysis. Based on the analyzation, the results are satisfied with homogeneity and long-term stability. The analyzed certification value of CRM includes the range of minimum and maximum value of point counting result for chrysotile; low concentration-1% (range, 0.25~3.00), high concentration-4% (range, 2.25~5.50).

Evaluation of Acute Toxicity of Black Pepper extracts, Clove bud, Rosemary and Origanum Essential oils (식물추출물 후추, 클로브버드, 로즈마리 및 오리가늄오일의 급성독성평가)

  • Jeong, Mi-Hye;Park, Soo-Jin;Kwon, Mi-Jeong;You, Are-Sun;Park, Kyung-Hun;Park, Jae-Yup
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Highly bio-active plant essential extracts and oils from pepper, clove bud, rosemary and origanum which are selected to develop environment-friendly insecticides was studied for their acute toxicity. The results of acute oral toxicity using rats showed $LD_{50}$ value of over 2,000 mg/kg bw for pepper, clove bud, rosemary and origanum oils. The calculated acute dermal $LD_{50}$ value of pepper was over 4,000 mg/kg bw and anther testing materials was over 4,000 mg/kg bw. The skin irritation test showed that pepper, clove bud and rosemary oils had no irritation while origanum oil had a moderate irritation. According to the eye irritation test, it showed that there was no irritation for pepper and rosemary oils, while there were irritation for clove bud and origanum oils. Consequently, pepper and rosemary oils were shown to be low in toxicity whereas clove bud oil was indicated to cause a mild eye irritability and origanum oil, causing a moderate skin and eye irritability.

Designing an Evaluation Method for the in-situ Impact Strength of Rollable Devices

  • Hyojung Son;Ki-Yong Lee;Byoung-Seong Jeong
    • Applied Chemistry for Engineering
    • /
    • v.35 no.2
    • /
    • pp.148-153
    • /
    • 2024
  • In this study, a methodology for evaluating impact strength in rollable devices was developed, focusing on measuring impact strength and evaluating rolling and unrolling durability simultaneously, with findings reported from tests on a real demonstration unit. The study utilized a flexible and rollable polyimide (PI) substrate for the evaluations. The chosen parameters for this methodology were a flat-type impactor, weights of 300 g, 500 g, and 1000 g, a rolling shaft ranging from 30 R to 5 R, and the positioning of the impactor. The results revealed that the difference in defect rates when comparing the 300 g and 500 g weights was minimal. However, the adoption of a 1000 g weight markedly increased the defect count due to damage to the PI film's surface. Furthermore, an uptick in rolling and unrolling cycles led to more pronounced surface scratches on the PI film. These methods and findings are poised to make a substantial contribution towards refining reliability testing for a wide array of rollable device applications, including smartphones, watches, pads, and wearable technology.