• Title/Summary/Keyword: tested result

Search Result 4,507, Processing Time 0.028 seconds

X-ray Micro-Imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-Bubbles (X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시 측정기술 개발)

  • Kim, Seok;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.659-664
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of 20∼60$\mu\textrm{m}$ diameter moving upward in an opaque tube (${\Phi}$=2.7mm) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

Assessment of Image Registration for Pressure-Sensitive Paint (Pressure Sensitive Paint를 이용한 압력장 측정기술의 이미지 등록에 관한 연구)

  • Chang, Young-Ki;Park, Sang-Hyun;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.271-280
    • /
    • 2004
  • Assessment of image registration for Pressure Sensitive Paint (PSP) was performed. A 16 bit camera and LED lamp were used with Uni-FIB paint (ISSI). Because of model displacement and deformation at 'wind-on' condition, a large error of the intensity ratio was induced between 'wind-on' and' wind-off images. To correct the error, many kinds of image registrations were tested. At first, control points were marked on the model surface to find the coefficients of polynomial transform functions between the 'wind-off' 'wind-on' images. The 2nd-order polynomial function was sufficient for representing the model displacement and deformation. An automatic detection scheme was introduced to find the exact coordinates of the control points. The present automatic detection algorithm showed more accurate and user-friendly than the manual detection algorithm. Since the coordinates of transformed pixel were not integer, five interpolation methods were applied to get the exact pixel intensity after transforming the 'wind-on' image. Among these methods, the cubic convolution interpolation scheme gave the best result.

Drag Reduction Effect by a Self-Adjustable Splitter Plate on the Flow over a Circular Cylinder (원형실린더 후류내의 가동형 와류분할판에 의한 항력 감소효과)

  • 박운진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1262-1275
    • /
    • 1993
  • The drag reduction effect of a freely-rotatable splitter plate was experimentally investigated in the 2-D wake behind a circular cylinder. By arranging the splitter plate to be aparted with a certain gap from the cylinder, the splitter plate was able to be aligned itself automatically to the flow direction in the tested range of 6.2$\times$$10^3$$\times$$10^4$. As a result, it was proven that the self-adjustable splitter plate always reduced effectively the drag imposed on the body against any arbitrary flow directions. In a specific range of Reynolds numbers, the drag reduction effect was dependent not only on the length of the splitter plate but also on the gap distance between the plate and the trailing edge of the body. For a splitter plate with a specific length, there existed a unique optimum range of gap distance to obtain successfully the drag reduction effect, however, the optimum range of gap distance was dependent on Reynolds number.

A Study on a Morphological Identification of Adenophora triphylla var. japonica, Codonopsis lanceolata, Adenophora remotiflora and Codonopsis pilosula (사삼(沙參), 양유근(羊乳根), 제니 및 당삼(黨參)의 형태(形態) 감별에 관한 연구)

  • Kim, Joo-Young;Lee, Young-Jong
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.121-126
    • /
    • 2007
  • Objectives : A morphological classification among Adenophora triphylla var. japonica, Codonopsis lanceolata, Adenophora remotiflora and Codonopsis pilosula was made through microscopic observation. Method : The slice of the tested material made by paraffin section technique was colored with Safranine Malachite Green contrast methods, and then observed and photographed by olymphus-BHT. Result : 1. Codonopsis pilosula is like a long cone, with amole-like projected parts at the beginning of the roots. 2. Adenophora triphylla var. japonica, Codonopsis lanceolata, Adenophora remotiflora, and Codonopsis pilosula are all similar as following: 1) Cork layers are composed of a few to over 10 subsidiary cells, with individual or a group of stone cells among them. 2) Phloem is wide and has a milk tube. Conclusion : Adenophora triphylla var. japonica, Codonopsis lanceolata, Adenophora remotiflora, and Codonopsis pilosula are all similar and difficult to be distinguished through microscopic observation, so that chemical experiments should be conducted for their identification.

  • PDF

A Study on a Morphological Identification of Sinomenium acutum, Cocculus trilobus and Aristolochia fangchi (방기류(防己類)의 형태(形態) 감별에 관한 연구)

  • Cho, Young-Du;Han, Hyo-Sang;Lee, Young-Jong
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • Objectives : A morphological classification among Sinomenium acutum, Cocculus trilobus and Aristolochia fangchi was made through microscopic observation. Method : The slice of the tested material made by paraffin section technique was colored with Safranine Malachite Green contrast methods, and then observed and photographed by olymphus-BHT. Result : 1. Fiber bundles of pericycle in S. acutum are like a crescent moon, stone cells were found among fiber bundles, and starch grain and raphides of calcium oxalate were included in parenchyma. 2. C. trilobus has the fiber bundle of pericycle resembling a crescent moon, but does not have the raphidesof calcium oxalate. 3. A. fangchi has the raphides of calcium oxalate, but does not have the fiber bundles of pericycle. 4. Stems and roots of S. acutum arc mostly similar, but only stems have the pith. Conclusion :' C. trilobus and A. fangchi can be distinguished from each other by the fiber bundles of pericycle and the raphides of calcium oxalate.

  • PDF

A Development of Recycled Glass Powder using Asphalt Concrete Filler and Evaluation of Practical Use at the Field (아스콘 채움재용 폐유리 미분말 개발 및 현장 적용 평가)

  • Ryu, Deug-Hyun;Jeon, Jun-Young;Jo, Shin-Haeng;Jun, Soon-Je
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.113-116
    • /
    • 2007
  • This is a research for evaluated recycled glass powder to add asphalt concrete filler. To make a comparative study, Mechanical performance of lime stone and slag dust Mixtures was evaluated according to test procedure. Lab. performance tests included marshall stability, indirect tensile strength, resilient modulus and wheel tracking. Water resistance tests were evaluated by marshall strength ratio and tensile strength ratio. In conclusion, Results of mechanical performance showed that recycled glass powder mixtures were equivalent to conventional mixtures. Especially, result of tensile strength ratio tested recycled glass powder mixtures was superior to conventional mixtures.

  • PDF

Development of Conversion Tools from V2 to V3 based on caAdapter (caAdapter에 기반 한 V2-V3 변환 도구 개발)

  • Um, Ki-Sung;Kim, Hwa-Sun;Hong, Hae-Sook;Cho, Hune
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.809-813
    • /
    • 2010
  • Although the goals of HL7 Version 2(V2) and Version 3(V3) are identical, the concepts of the implementation and technological basis are different; this makes their versions inconvertible. This problem interrupts technological innovation advanced from V2 to V3 and has been raised as a new type of barrier in the field of medical information system. This study intends to develop software to convert V2 to V3 which can be utilized in the actual medical environment. Since it is practically difficult to develop the whole tools that automatically change total V2 messages into V3 messages, this article has designed, implemented, and tested the software that allows mapping between V2 and V3 which function as tools. In order to test this program, it has used ADT^A03 of five V2 messages to generate V3 messages. It is expected that the result of this research will be one of the new methods allowing conversion between V2 and V3.

Purification of Isoflavone from Soybean Hypocotyls using Various Resins

  • Choi Yeon-Bae;Kim Kang-Sung
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.3
    • /
    • pp.221-226
    • /
    • 2005
  • Isoflavone was extracted with various concentration of aqueous methanol using whole hypocotyls as the starting material. Whole hypocotyls were preferred as the raw material because the residue could be easily removed from the solvent after the extraction process. Extraction yield was almost constant at the methanol concentration of $20-80\%$. Most of the isoflavone was extracted within 1 hr, and the extraction yield remained almost constant thereafter. When the concentration of methanol was $80\%$, the content of total solid was reduced due to the reduced extraction of contaminating protein as the result of protein insolubilization. Among resins tested, Diaion HP-20, Amberlite XAD-16, and Amberlite IRC-50 showed the highest capacity to absorb the compound. Open column chromatography with Diaion HP-20 showed that $80\%$ aqueous ethanol was most efficient as the eluting solvent with final recovery of the phytochemical being more than $95\%$. Maximum adsorption of the phytochemical occurred at the acidic pH 2-4. When the spatial velocity was increased to 15 and more, the degree of adsorption was decreased, whereas below spatial velocity of 15, the adsorption capacity of isoflavone to the resin was almost constant. The purity of the isoflavone purified by column chromatography was $78\%$.

Mechanical Anisotropy of Jurassic Granites in Korea (국내 주라기 화강암의 역학적 이방성)

  • 서용석;박덕원
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.257-266
    • /
    • 2003
  • Jurassic granites of three sites, Pocheon, Geochang and Habcheon, were tested to investigate the effect of microcracks on Physical and mechanical properties of the granites. Fifteen oriented core specimens were used for the physical property test. The test result shows that porosity is almost proportioned to water content. P-wave velocity is the highest in the direction of axis ‘H’, intersection of two major microcrack sets and the lowest in the axis ‘R’, normal to the rift plane. Compressional strength tests were carried out for each core specimen taken parallel with axes ‘R’, ‘G’ and ‘H’, measuring strains. The results revealed a strong correlation between microcrack orientation and other mechanical properties such as rock strength.

A Study on PWM Converter/Inverter Drive System by a Fuel Cell Simulator (연료전지 Simulator에 의한 PWM 컨버터/인버터 구동시스템에 관한 연구)

  • 이태원;장수진;김진태;구자성;원충연;김창현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.222-230
    • /
    • 2004
  • In this paper, a 3㎾ fuel cell generation system with an active fuel cell simulator has been proposed. The developed fuel cell simulator generates the actual voltage and current output characteristics of the Polymer Electrolyte Membrane Fuel Cell (PEMFC), so that the overall performance and the dynamics of the proposed system could be effectively examined and tested. In This paper, at first, the system configuration and operational principle of the developed fuel cell simulator has been investigated and the design process of the fuel cell generation system is explained in detail. In addition, the validity of the proposed system has been verified lly the informative simulation and experimental result