• 제목/요약/키워드: test system

검색결과 26,704건 처리시간 0.052초

매단 천장의 실간 공기전달음 실험실 측정 방법 고찰 (Investigation on the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling)

  • 양관섭;이근희;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1126-1131
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO or ASTM have been used for evaluating sound performance in domestic so far. In this study, every regulation from ISO, ASTM, especially for airborne sound insulation against suspended ceiling system, is analyzed in order to apply to establishment of Korean Standards on test methods and test facility of suspended ceiling system and materials.

  • PDF

대차틀의 구조해석 및 하중시험에 관한 연구 (A study on the Structural Analysis and Loading Test of Bogie Frame)

  • 김원경;윤성철
    • 한국철도학회논문집
    • /
    • 제8권6호
    • /
    • pp.566-572
    • /
    • 2005
  • This paper describes the results of structural analysis and loading test of a bogie frame. The purpose of the analysis and test is to evaluate the safety and functionality of the bogie frame under maximum load. The bogie system consist of the bogie frame, suspensions, wheel-sets, a brake system and a transmission system. Of these components, the bogie frame is the major components subjected to the vehicle and passenger loads. The evaluation method used the JIS E 4207 specifications throughout the FEM analysis and static load test. The test results have shown the bogie frame to be safe and stable under design load conditions.

Insulation Design and Reliability Evaluation of ±80kV HVDC XLPE Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1002-1008
    • /
    • 2014
  • This paper describes insulation design and its reliability evaluation of ${\pm}80kV$ HVDC XLPE cable. Recently, the construction of HVDC transmission system, which is combined overhead line with underground cable, has been completed. This system is installed with existing 154 kV AC transmission line on the same tower. In this paper, the lightning transient analysis is firstly reviewed for selection of basic impulse insulation level and nominal insulation thickness. Then the electrical performance tests including load cycle test and superimposed impulse test based on CIGRE TB 496 are performed to evaluate the reliability of newly designed HVDC cable. There is no breakdown for ${\pm}80kV$ HVDC XLPE cable during electrical performance test. Finally, this system is installed in Jeju island based on successful electrical performance test (Type test). After installation tests are also successfully completed.

Imaging System Wavefront Analysis Using Ronchi Test

  • Lee, Sunwoo;Park, Woojin;Yu, Joonkyu;Pak, Soojong
    • 천문학회보
    • /
    • 제43권2호
    • /
    • pp.56.2-56.2
    • /
    • 2018
  • Ronchi test is an optical test to check the quality of an imaging system. Wavefront of the optical system can be obtained from the Ronchi patterns. In this poster, we present the Ronchi test module and the optical quality evaluation results. The test module consists of a light source, a pinhole, a beam splitter, a Ronchi ruling and a flat mirror. The test module can be simply adapted to any optical systems. We compare measured surface data for both aluminum and glass parabolic mirrors by analyzing the Ronchi patterns.

  • PDF

소형콘관입시험(Miniature CPT)의 국내현장적용 사례분석 (Case Studies on the Field Application of Miniature CPT's in South Korea)

  • 윤성수;황대진;김준오;지완구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.269-281
    • /
    • 2010
  • The cone penetration test(CPT) has been increasingly used for in situ site characterization. However, the use of CPT is often limited due to specific site conditions depending on the cone size, geometry, and capacity of the CPT system used. In South Korea, it has generally been considered that the CPT could be satisfactorily performed only in soft soils. Louisiana State University/ Louisiana Transportation Research Center has implemented a field-rugged continuous intrusion miniature cone penetration test (CIMCPT) system since the 1990s. The miniature cone penetrometer of the CIMCPT system has a cross-sectional cone area of $2cm^2$ allowing finer soil profiles compared to the standard $10cm^2$. The reduced cross-sectional area also enables a system capacity reduction leading to cost saving and ease in maintenance. In addition, the continuous intrusion mechanism allows fast and economic site investigations. Samsung C&T Corporation has recently implemented a similar CIMCPT system. In this study, case studies on the field application of Samsung CIMCPT system for the last 2 years are presented to illustrate its performance investigation and its usefulness and limitation. Results of the case studies show that the CIMCPT system can be applied to soils with cone tip resistance($q_c$) values up to about 30MPa and allows a reliable and useful way to characterize soft soils. The results also show that the rod buckling limits the investigation depth by the system and the large contact pressure of the CIMCPT truck prevents the use of the system at sites with soft surface soils. According to the results of the case studies, the Samsung CIMCPT system has been being upgraded with a miniature cone with a longer rod, a crawler-type transportation system, a pre-boring system, and so on.

  • PDF

발사체 열제어/화재안전 시스템 설계 및 시험 (Design and Test of Thermal Control and Fire Safety System for Space Launch Vehicle)

  • 고주용;오택현;이준호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1006-1010
    • /
    • 2017
  • 본 논문은 발사체의 지상대기 및 운용 중 격실 내부의 열제어 및 화재/폭발 방지를 위해서 적용되는 열제어/화재안전계에 대한 설계 및 시험에 대해서 기술한다. 고려된 시스템은 한국형발사체 개발의 일환으로 진행되고 있는 시험발사체의 열제어/화재안전 시스템으로 이 시스템은 나로호의 경험을 토대로 고압 시스템을 적용한다. 고압 및 저압 시스템의 선정은 발사대의 가스공급 설비 및 발사체의 특성을 고려해서 선정하며 이에 따라 시스템의 구성도 달라진다. 결과적으로 개발된 시스템은 시험을 통해서 초기의 설계 조건을 만족하는 결과를 얻을 수 있음이 확인되었으며, 이러한 시스템은 한국형발사체의 개발에 그대로 확장되어 적용될 예정이다.

  • PDF

비행제어시스템 설계 및 검증 절차 (Flight Control System Design and Verification Process)

  • 김종섭
    • 제어로봇시스템학회논문지
    • /
    • 제14권8호
    • /
    • pp.824-836
    • /
    • 2008
  • Relaxed static stability(RSS) concept has been applied to improve aerodynamic performance of modern version supersonic jet fighter aircraft. Therefore, flight control systems are necessary to stabilize an unstable aircraft, and provides adequate handling qualities and achieve performance enhancements. Standard FCSDVP (Flight Control System Design and Verification Process) is provided to reduce development period of the flight control system. In addition, if this process is employed in developing flight control system, it reduces the trial and error for development and verification of flight control system. This paper addresses the flight control system design and verification process for the RSS aircraft utilizing design goal based on military specifications, linear and nonlinear system design and verification based on universal software, handling quality test based on HILS(Hardware In-the-Loop Simulator) environment, and ground and flight test results to verify aircraft dynamic flight responses.

슬리브관을 갖는 로드셀을 이용한 주퇴봉 당김력 계측시스템 개발 (A Development of the Recoil Rod Pull Force Measurement System Using the Load Cell with Sleeve)

  • 최주호;홍성수;유준
    • 제어로봇시스템학회논문지
    • /
    • 제7권2호
    • /
    • pp.152-159
    • /
    • 2001
  • This paper presents a development of the recoil rod pull force measurement system suing the load cell with a sleeve normally available in the recoil system test. The commercial load cell cannot be used in the test of recoil system floating the breach contact point freely in the air. The load cell is designed and manufactured to meet the recoil system test condition. Theoretical analysis and experimental results show that the accuracy of the developed measurement system is within $\pm$0.5%. We notice that the measurement technique proposed in this paper is accurate and useful in the recoil rod pull force measurement of the recoil system.

  • PDF

500MW 동기발전기용 시뮬레이터 탑재형 디지털 삼중화 여자시스템 개발 (Development of the Triple Modular Redundant Excitation System with Simulator for 500MW Synchronous Generator)

  • 류호선;차한주
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.70-75
    • /
    • 2014
  • TMR(triple modular redundant) digital excitation system with simulator is developed for tuning optimal control parameters during commissioning test and coping with system faults rapidly. A new system which mocks up virtual generator, turbine, grid can simulate as if excitation system is connected to a real generator system by setting four switches. The maintenance crew using the simulator is able to test perfectly the phase controller rectifiers, field breaker, sequence relays as well as TMR controller of the excitation system. Commissioning and performance results about the excitation system with simulator is discussed. The trial product was installed and operated at a 500MW thermal power plant after the commissioning test.

지상연소시험설비의 제어시스템 구축 방안 (A Construction Scheme of Control System in a Ground Hot-firing Test Facility)

  • 이광진;김지훈;김승한;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.468-471
    • /
    • 2012
  • 본 논문은 우주발사체에 사용되는 추진기관의 성능평가를 수행하기 위한 지상연소시험설비의 이중화 또는 삼중화 제어시스템의 구축 방안을 다루고 있다. 이중화된 제어시스템의 경우 수동제어 콘솔을 설치하여 삼중화 제어시스템을 모사할 수 있었고, 운용자들의 무분별한 조작을 통제하기 위한 제어실 내 제어 콘솔의 배치 안을 제시하였다.

  • PDF