• 제목/요약/키워드: test standard

검색결과 8,501건 처리시간 0.039초

작업차량 장착용 충격흡수장치(TMA) 성능평가기준 수립 및 개발 연구 (A Study on the Development and of Establishment Performance Evaluation Criteria of Working Truck Mounted Attenuator)

  • 주재웅;장대영;박제진
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.185-191
    • /
    • 2012
  • Rear collisions to expressway work trucks result many casualties these days. But, currently, no special measure are being taken except deploying sign trucks behind the working trucks. In the U.S and Europe, trucks with TMA(Truck Mounted Attenuator) are being deployed behind the working truck, which is regarded as the standard method for work area safety, thereby reducing the fatality rates and property damage tremendously. Also, standard for the performance of TMA are established and TMA can be used in the field only when it satisfies the standard. In Korea, neither the standard for nor any guide to the TMA exists. In the situation some manufacturer developed TMA without proper performance evaluation and marketed limited number of TMAs in the field. In the study, NCHRP350, which is the performance standard of expressway safety features of U.S. and materials related to the TMA standard in Europe have been reviewed to establish the Korean performance criteria. Based on the review, and incorporating existing Korean standard for crash cushions, domestic standard for TMA has been proposed and applied in developing Korean TMA and crash tested it to verify the performance. The original design developed was crash tested and modified. The newly proposed design was studied using impact simulation program several times. Modifications were made after each simulation and prototype was built and crash tested as per the newly established TMA performance criteria.

메틸렌 블루 시험을 이용한 콘크리트용 부순모래에 함유된 미세골재의 사용타당성에 관한 기초적 연구 (A Fundamental Study on the Adequacy of Use of Micro Fines Including in Crushed Aggregate Using Methylene Blue Test)

  • 안남식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.205-210
    • /
    • 2002
  • As the deposits of natural sands have slowly been depleted, it has resulted in an increase in manufactured fine aggregate (MFA). Standard specifications for fine aggregate for concrete contained in KS F 2558 permit a maximum of 7 percent finer than the No. 200 sieve (75${\mu}{\textrm}{m}$). Since the production process for MFA normally generates 10 to 20 percent of micro fines-which is defined as aggregates passing the No. 200 sieve (75${\mu}{\textrm}{m}$)-more than permitted by specifications, Excess fines must be removed by screening and/or washing operations. The amount of by-products will continue to grow as production increases with environmental discharge restrictions. This fundamental study focuses on experimental research for the adequacy of use of micro fines included in crushed aggregate using methylene blue test. Total of 63 types of sands from seven different rocks were tested. Based on the test results, the methylene blue test was turned out to be a good indicator of the quality of micro fines for concrete and a supplementary article and an amendment of the KS standard were recommended.

  • PDF

풍력발전기 소음 성능 실증 (Noise Performance Test and Evaluation of a Wind Turbing Generator)

  • 김석현;김태형;박무열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

지하구 케이블의 연소특성 실험 (Experiments on the Behavior of Underground Utility Cable in Fire)

  • 박승민;김운형;윤명오
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.75-80
    • /
    • 2002
  • 지하공동구에 사용되는 케이블의 연소특성 중 열방출량과 연기 유독성 실험을 수행하였다. 열 방출량 실험은 22.9 kv 전력용 케이블을 대상으로 ISO 9705 규격의 공간에서 수행하였으며 유독성가스의 정량적 위험성 평가를 위하여 NES 713(British-Naval Engineering Standard)을 적용하였다. 실험 결과 측정높이 1.2 m를 기준으로 계산한 케이블의 열 방출 율은 60 kW로 예측되었다. 한편, 케이블의 연기유독성을 위한 NES 실험 결과, 인체에 치명적인 CO의 경우 30분 노출시 사망에 이를 수 있고 의식불명상태가 될 수 있는 수준으로 판정되었다

내압력.온도센서를 갖는 표준 인장시편용 사출금형 (Injection Mold with Cavity Pressure/Temperature Sensors for Standard Tensile Test Specimen)

  • 이도명;한병기;이성희
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.84-90
    • /
    • 2007
  • In this study, design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed fur tensile test specimen. International standard system for plastic tensile specimen was applied to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of the injection mold to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and then tensile test of the manufactured polycarbonate specimens was also performed. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

고도모사 환경챔버 개념 설계 (Design Principals of High Altitude Environmental Test Chamber)

  • ;공창덕;최경호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.403-406
    • /
    • 2009
  • 본 연구는 MIL-HDBK-310을 기준으로 한 고도별 대기상태 즉, 온도, 습도 및 압력을 모사하여 고도에 따른 피시험물의 성능을 MIL-STD-810F 및 AIAA-2466에서 정한 시험 절차에 따라 평가하는 챔버를 개발하는 것이다. 이를 위한 대기차단 구조물, 시험부 및 공기순환유로, 고도모사 배기장치, 온도제어장치, 습도제어장치 및 설비제어장치 등을 설계하는데 고려하여야 할 사항을 기술하였다.

  • PDF

전류변성기 비교기의 비오차 평가 기술 (Evaluation Technique for Ratio Error of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.

통신 프로토콜 시험항목의 오류 발견 능력 평가 방법 (Fault coverage evaluation method of test case for communcation protocol)

  • 김광현;허기택;이동호
    • 한국통신학회논문지
    • /
    • 제21권8호
    • /
    • pp.1948-1957
    • /
    • 1996
  • 통신 프로토콜의 적합성 시험은 구현된 프로토콜이 표준규격과 동일하게 구현되었는지를 검사하는 과정을 말한다. 생성된 시험 항목이 어느 정도의 오류를 발견해 낼 수 있는지를 평가함으로써 적합성 시험의 효율성을 평가하는 하나의 기준으로 사용될 수 있다. 시험 항목의 오류 발견 능력의 평가 방법은 주로 수학적 평가 방법과 시뮬레이션을 이용한 연구가 이루어져 왔다. 본 논문에서는 기존 평가 방법의 문제점을 지적하고 오류 모델을 사용하여 생성된 시험항목에 대한 새로운 오류 발견 평가 모델을 제시하였다. 그리고 제안된 평가 모델을 기존의 방법과 비교, 분석하여 타당성을 입증하였다.

  • PDF

사출성형과정의 잔류응력을 고려한 표준인장시편의 선형구조해석 (Linear Structural Analysis of Standard Plastic Tensile Specimen with Residual Stress Induced by Injection Molding)

  • 이도명;한병기;이성희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.579-580
    • /
    • 2006
  • In this study, an injection mold of tensile test specimen was manufactured by international standard. Pressure and temperature in the cavity of the injection mold was measured by sensors. Simulation of injection molding process was performed with the same condition of experiment and linear structural tensile analysis was also performed with the initial condition of the residual stress induced by injection molding analysis. Normalized elastic coefficient of tensile test was compared with that of structural analysis. It was shown that the residual stress induced by injection molding has an effect on both the experiment of tensile test and linear structural analysis.

  • PDF

항공기 왕복엔진 냉각설계 및 인증시험 (Cooling Design and Flight Test for Airplane Reciprocating Engine)

  • 이강이;박종혁;박성환
    • 항공우주시스템공학회지
    • /
    • 제6권2호
    • /
    • pp.35-41
    • /
    • 2012
  • A reciprocating engine installed on a normal category airplane shall be effectively cooled by air flown through the engine compartment. A airplane powerplant designer has to design cooling air inlets, baffles, seals, and outlets to maintain cylinder head temperatures and oil temperature under the limits, and show compliance with appropriate airworthiness standard. In this study, cooling designs of the installed engine and compliance requirements applicable to the cooling designs were reviewed, and engine cooling flight test results were evaluated for design changes. Engine cooling certification test will be conducted in a next step.