• 제목/요약/키워드: test standard

검색결과 8,477건 처리시간 0.035초

부산 402호의 조종 성능에 관한 연구 (Maneuverabilities of the M . S . Pusan 402)

  • 김삼곤
    • 수산해양기술연구
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 1986
  • The maneuverabilities of the M. S. PUSAN 402 are studied, based on maneuvering indices and the data obtained from her Z test. The results obtained are summarized as follows: 1. The maneuvering indices K' and T' of the M. S. PUSAN 402 are 1. 490, 1.030 at 10$^{\circ}$ Z test and 2.644, 1.153 at 20$^{\circ}$ Z test and 3.382. 1. 027 at 30$^{\circ}$ Z test respectively. The above calculated values K', T' showed that her maneuverabilities are more increased when the rudder is used to large angle than to smaIl angle. 2. As her maneuvering indices K' and T' at 10$^{\circ}$ Z test are higher than the standard maneuvering indices of fishing boats, her turning ability was found to be higher but her obeying ability lower. 3. When the M. S. PUSAN 402 took a turn at her 10$^{\circ}$ test, running distance was about 8.4 times her own length and didn't exceed the standard maneuvering distance, 5 to 11 times ship's own length, therefore she was considered to have good maneuverabilities syntheticaIly.

  • PDF

Quantile-based Nonparametric Test for Comparing Two Diagnostic Tests

  • Kim, Young-Min;Song, Hae-Hiang
    • Communications for Statistical Applications and Methods
    • /
    • 제14권3호
    • /
    • pp.609-621
    • /
    • 2007
  • Diagnostic test results, which are approximately normal with a few number of outliers, but non-normal probability distribution, are frequently observed in practice. In the evaluation of two diagnostic tests, Greenhouse and Mantel (1950) proposed a parametric test under the assumption of normality but this test is inappropriate for the above non-normal case. In this paper, we propose a computationally simple nonparametric test that is based on quantile estimators of mean and standard deviation, instead of the moment-based mean and standard deviation as in some parametric tests. Parametric and nonparametric tests are compared with simulations under the assumption of, respectively, normality and non-normality, and under various combinations of the probability distributions for the normal and diseased groups.

대용량 사이리스터 특성평가 장비의 설계 및 제작 (Design of Characteristics Test Equipment for a Large Capacity Thyristor)

  • 서길수;김형우;김기현;김남균;김은동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.567-572
    • /
    • 2005
  • Recently, application area of the thyristor is extends to power conversion systems, such as HVDC, BTB, SVC and FACTS. Therefore, reliability diagnostic technique on thyristor is needed to obtain stability and maintenance of power conversion systems. To measure the characteristics of the thyristor, test equipments which based on IEC 747-6 and KS C 7023 standard are needed. In this paper, we presents the design and manufacture of the test equipments for 6.5kV/4.2kA thyristor which used in thyristor valve of HVDC conversion systems by using test standard. Voltage, current, dv/dt and turn-off time test equipments were designed and manufactured. Each systems were made separately, but unity operation can possible.

750kW 풍력발전기의 소음실증 (Noise Test and Evaluation of a 750kW Wind Turbine Generator)

  • 김석현;허욱;이현우
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

소구경 총열 표면처리에 관한 연구 (Study on Surface Treatment over the Barrel of Small Arms)

  • 채제욱;김인우;이영신
    • 한국군사과학기술학회지
    • /
    • 제7권1호
    • /
    • pp.5-12
    • /
    • 2004
  • This paper includes the comparative study between Cr plating and nitriding process with an aim at improving corrosion, wear and maintainability for KNR(Korean Next Generation Rifle) 5.5mm barrel. The endurance test was conducted to compare the performance of standard barrel, Cr plating barrel and nitriding barrel. Main activities are described as follows; optimal Cr plating and nitriding process set-up for KNR 5.56mm barrel; durability test of each barrel(20,000 rounds); salt water immersion test; dispersion, initial velocity, inner diameter data acquisition. According to the results of this firing test, Cr plating barrel is superior to standard barrel and nitriding barrel in view of corrosion, wear and maintainability.

The Admissibility of Some Nonparametric Tests

  • Li, Seung-Chun
    • Journal of the Korean Statistical Society
    • /
    • 제26권2호
    • /
    • pp.223-229
    • /
    • 1997
  • It is demonstrated that many standard nonparametric test such as the Mann-Whitney-Wilcoxon test, the Fisher-Yates test, the Savage test and the median test are admissible for a two-sample nonparametric testing problem. The admissibility of the Kruskal-Wallis test is demonstrated for a nonparametric one-way layout testing problem.

  • PDF

국내 현장가열재생아스팔트 시공 혼합물 시험평가 (A Case Study of Hot In-Place Recycling Asphalt Mixture in Korea)

  • 권수안;양성린;이재준;홍재청;임재규
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.57-63
    • /
    • 2013
  • PURPOSES: This study is to investigate the Hot In-Place recycling asphalt mixture in Korea using field produced materials. METHODS: Hot In-Place reclaimed asphalt mixture was investigated to evaluate the mixture properties based on various test results such as Marshall Test, Indirect Tensile Test, TSR, and Wheel Tracking Test. These test values were compared with domestic standard specification. RESULTS: The result of the laboratory experiment indicates that the Hot In-Place Reclaimed(HIR) asphalt mixture produced at the field constrution site was satisfied all of the test criteria such as Indirect tensile test, Marshall and TSR test, and wheel tracking test. During the test, the research team found that current HIR system is required an extention of mixing time to improve quality and to reduce variation of sample to sample. Although the current HIR mixture was passed the test criteria, there is a potential capability to enhance the mixture properties as extend mixting time. CONCLUSIONS: Based on these laboratory test results, It would be concluded that domestic HIR mixture's properties were satisfied all standard specification related with evaluation of recycling asphalt mixtures. Based on this case study result, there is a chance to save construction cost and increase the usage of reclaimed asphalt concrete in the future.

제강슬래그의 매체접촉형 재활용에 따른 중금속 용출특성 및 물벼룩 생태독성 평가 (Leaching and Acute Toxicity Test of Steel-making Slags for Media Contact Recycling)

  • 김동현;조봉석;신원식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제29권1호
    • /
    • pp.72-83
    • /
    • 2024
  • Most of the slags generated from steel-making industry in Korea are recycled into media-contact aggregates such as fill and cover materials. For their use as media-contact aggregates, the slags must meet not only the waste quality criteria, but also the Daphnia magna acute toxicity test criteria. In this study, Korean Leaching Test ES 06150.e (Korea), Japanese Leaching Test JIS K 0058-1(Japan), Detuch Leaching Test DIN 19529 (Germany), Toxicity Characteristic Leaching Procedure (USA) were conducted for batch leaching test of slags from 6 Korean steel-making companies. In addition, Korean Standard up-flow percolation test (ES 06151.1) mimicking field conditions was conducted to assess the impact of the slag leachate on the surrounding environment indirectly. Heavy metals such as Cr6+ and Zn2+ were detected from both extractant and leachate samples, but all of them did not exceed waste quality criteria of each country. However, Daphnia magna acute toxicity tests using the leachate samples from up-flow percolation test with slag alone and slag/natural soil conditions exceeded ecotoxicity standard (TU=2) due to their high pH (11.3-12.5). After neutralizing the pH of the slag leachate to 6.5~8.5, the Daphnia magna mortality and immobilization were reduced to satisfy ecotoxicity standard. As the reducing pH of slag leachate would be extremely difficult, appropriate recycling management considering the physicochemical characteristics of he slags should be stuided further.

불꽃試驗용 標準試片 의 熱擴散 係數 (The Thermal Diffusivity of Standard Pieces for Spark Test)

  • 차경옥;이관수;이흥주
    • 대한기계학회논문집
    • /
    • 제7권3호
    • /
    • pp.319-327
    • /
    • 1983
  • The thermal diffusivity one of the series of standard pieces for spark test are determined by the flash method. The standard pieces are composed with carbon steels, structural carbon steels, alloy steels and high speed tool steels. In order to compute the thermal conductivity of the standard pieces, their specific heats are measured by a differential scanning calorimeter. The thermal conductivities are calculated from the data of specific heat, density and thermal diffusivity. To increase the accuracy of data for the thermal diffusivity by data reduction excursion method in the flash method, the governing heat diffusion equation, which is closely described experimental conditions with the finite pulse and the heat loss from the sample surfaces, is solved. In this analysis an integral transform is used.

확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가 (Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function)

  • 최정훈;구재민;석창성;송원근
    • 대한기계학회논문집A
    • /
    • 제32권9호
    • /
    • pp.707-712
    • /
    • 2008
  • The fatigue characteristics of a material or a structure are generally derived from fatigue tests of standard specimens. However, test results of standard specimens are different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristics of a real waterwork pipe. Also, to evaluate fatigue characteristic based on life distribution, the statistical fatigue characteristics were analyzed by the normal distribution and related data of P-S-N curve.