• Title/Summary/Keyword: test standard

Search Result 8,477, Processing Time 0.04 seconds

The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate (ESR 자동분석기를 이용한 내부정도관리방법)

  • Cho, Young Kuk;Sim, Hyun-Seol;Song, Woon Heung;Park, Quehn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

Standard Image Acquisition Characteristics Tests for Image Sensors and Modules (이미지 센서 및 모듈의 표준 영상 취득 테스트)

  • Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.77-95
    • /
    • 2014
  • In general, image acquisition characteristics tests of image sensors and modules vary widely according to the characteristics of image sensors and modules under test, the application purpose of target devices where image sensors and modules are mounted, and the functions of test equipments. However, some de facto standard tests are frequently used in industry fields. They differ only in several parameters e.g. thresholds for fault detection, and they can be applied to most image sensors and modules. In this paper, 11 typical tests are explained in detail, and they are described in a simple and clear form under single framework, which significantly reduces errors and saves efforts.

Design and Performance Analysis of Emulator for Standard Conformance Test of Active RFID

  • Song, Tae-Seung;Lee, Wang-Sang;Kim, Tae-Yeon;Lyou, Joon
    • ETRI Journal
    • /
    • v.31 no.4
    • /
    • pp.376-386
    • /
    • 2009
  • An active radio frequency identification (RFID) system has the advantages of a long identification distance and a good identification rate, overcoming passive RFID drawbacks. Therefore, interest in the development of active RFID systems has been gradually increasing in areas of harbor logistics and national defense. However, some identification failures between active RFID systems developed under the same standards have been reported, presumably due to a lack of development of accurate evaluation methods and test equipment. We present a realization of the hardware and software of an emulator to evaluate the standard conformance of an active RFID system in a fully anechoic chamber. The performance levels of the designed emulator are analyzed using Matlab/Simulink simulations, and the applicability of the emulator is verified by evaluating the standard conformance of a real active RFID tag. Finally, we propose a new evaluation method by incorporating a self-running test mode environment into the RFID tags to reduce testing time and increase testing accuracy. The application of the suggested method to actual tags improves measurement uncertainty by 0.56 dB over that obtained using existing methods.

The Validation of Newly Developed Portable Slipmeter (새롭게 개발된 휴대용 미끄럼 저항 측정기의 성능검증)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.18-23
    • /
    • 2013
  • The purpose of this study were to develop and validate a prototype slipmeter used on-site floor. The developed slipmeter was dreg sled type. It measured static coefficient of friction(SCOF). The developed slipmeter was evaluated with ASTM 2508-11 which use four different standard surfaces(polished granite, glazed porcelain, vinyl composite tile, and ceramic tile). The SCOF was then measured with developed slipmeter under the three different contaminants and seven different floors. The test results of slipmeter were also compared with those of BOT-3000, floor surface roughness, and human perception. The test results revealed that developed slipmeter successfully ranked all four standard surfaces and differentiated among standard surfaces with varying degrees of slipperiness. The developed slipmeter couldn't properly measure slipperiness under the two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol). The test results of developed slipmeter had stronger correlation with those of BOT-3000 and floor roughness under the water and detergent solution than under the glycerol. The test results of developed slipmeter also showed stronger correlation with those of BOT-3000 and surface roughness than those of human perception. The newly developed slipmeter had been found to give consistent results under the test conditions except for two kind of floors(polished tile, ground steel plate) and one kind of contaminant(glycerol).

Comparative Study on Test Methods for Mechanical Properties of Structural Adhesives Used in FRP Strengthening (구조보강용 FRP 함침·접착수지의 역학적 특성 분석을 위한 시험방법 비교 연구)

  • You, Young Chan;Choi, Ki Sun;Kim, Keung Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2008
  • Pull-off test is generally used to evaluate bond strength of FRP composite with concrete at job site. However, some damages on FRP composites can not be avoided during pull-off test and moreover test range of pull-off strength is limited by maximum tensile strength of concrete. Accordingly, it is required to set-up a test method that can evaluate mechanical properties of structural adhesive indirectly prior to pull-off test. In this study, the standard test methods for structural adhesive which can simply evaluate mechanical performance of adhesive were suggested through comparative experiments from each different standard in various countries. Particularly, gluing thickness of adhesive in tensile lap-shear tests, the section dimension of compression and bending test specimens become unified, and standard test specimen size is achieved by test results.

The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA (FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구)

  • Seo, Youngkyo;Jung, Dohyun;Yu, Sangseok;Rha, Wanyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

An Experimental Study on the Dynamic Behavioral Characteristics of Bottom Ash (석탄회의 동적거동 특성에 대한 실험 연구)

  • Yoon, Won-Sub;Han, Jae-Woon;Shin, Seoung-Gu;Chae, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1142-1150
    • /
    • 2010
  • An elementary particle of bottom ash is similar to fine sand. So which expected from replace expensive sand. Therefore, this study conducts cyclic triaxial test and a resonant test using relative density, which is obtained from a relative density test of bottom ash and standard sand. Also, it compares antiseismic characteristics of bottom ash and standard sand in order to analyze the possibility of commercial use as a construction material.

  • PDF

Certificate Test on Crystalline Silicon Photovoltaic Module (결정질 실리콘 태양전지모듈의 인증시험 현황)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.27-30
    • /
    • 2009
  • In this paper, we introduce the status of certificate test on crystalline silicon photovoltaic module in Korea. Up to 3. 2009, about 149 models have passed certificate test under KS C IEC61215 standard. Most products are from Korea, Japan, China. And some are from USA, German and Taiwan. A few environmental test items' results and standard test methods will be discussed. The detail discussion will be shown in the following paper.

  • PDF

A Study on an Environmental Test Sequence for Electrical Units on Aircraft (항공기 전장품의 환경시험순서에 관한 연구)

  • Yang, Jung Ho;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.114-121
    • /
    • 2014
  • An environmental test has been performed in order to improve the lifetime and reliability of the electrical units on aircraft. However, faults occurring in the field of aircraft have been difficult to predict and prevent, and new concepts for reliability testing are desired. Therefore, a composite reliability test sequence was proposed in the conventional studies. This study introduces test sequence guidelines based on relevant principles and considerations for electronic testing according to International Standard IEC-60068-1 and the United States Military Standard MIL-STD-810G. In addition, we analyze possible causes of failure using two-step QFD based on aircraft operation scenarios. Finally, the proposed test sequence can reproduce various and realistic failure modes for electrical units on aircraft.

The Effect of Exercise Adaptive Training on Motor Function after Experimental brain ischemia in Rats (실험적 뇌허혈로 인한 편마비 흰쥐에서 운동 적응 훈련이 기능 회복에 미치는 영향)

  • Kwon, Young-Shil;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.529-535
    • /
    • 2001
  • The purpose of this study was to test that the exercise adaptive training enhance behavioral outcome significantly after focal brain ischemia in rats. After occlusion of middle cerebral artery in rats, they were housed in individual standard cages fur 24 hours. The control group was sacrificed 24 hours after ischemic event. The experimental group I was housed in standard cages for 7days. The experimental group ll was housed in enriched environment and had got exercise adaptive training fur 7days. The rats were examined five motor behavioral tests. In motor behavioral tests :postural reflex test, limb placement test, beam-walking test, rotarod test, horizontal wire test. The outcomes of control group and group I were significantly lower than the group II. The conclusion was that exercise adaptive training induced functional repair.

  • PDF