• Title/Summary/Keyword: test specimens

Search Result 6,469, Processing Time 0.051 seconds

Antiemetic Effect of Dexamethasone in Dogs Sedated with Xylazine (Xylazine hydrochloride로 진정시킨 개에 대한 Dexamethasone의 항구토 효과)

  • Yang Jung-hoon;Kang Han-sem;Bae Jae-sung;Song Chang-hyun;Kim Jung-eun;Jin Hee-kyung;Jang Kwang-ho
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • This prospective study aimed to assess the efficacy of dexamethasone to prevent xylazine induced emesis in dogs. The antiemetic effect of graded, single high-dose intravenous dexamethasone against xylazine hydrochloride was studied. Clinically healthy mixed breed dogs that weighed $ 4.64\pm1.25kg$ were used in this study. Food and water were given 3 hours before the experiment. Venous blood specimens were collected from all experimental animals for hema-tological and blood chemical test pre- and post-experiment. Twenty-eight experimental animals were randomly divided into 4 groups; the group treated with 0.2ml/kg of normal saline (Control group), the groups treated with 1mg/kg (D1 group), 2mg/kg (D2 group) and 4 mg/kg of dexamethasone (D4 group). Three doses of the dexamethasone or normal saline was administered intravenousely to each group and after 5 minutes, xylazine (2.2 mg/kg) was administered intramuscularly. The time until onset of the first emetic episode and rate of emesis were investigated. At the same time, the extent of sedation was scored subjectively 5, 15, 30 and 60 minutes after injection of xylazine hydrochloride using Visual Sedation Score. The time until onset of the first emetic episode was $203.25\pm11.35$ sec in Control group, $187.33\pm48.0l$ sec in D1 group and 218.33± 13.58 sec in D2 group. The rate of xylazine induced emesis were $57\%$ in Control group and $43\%$ in D1 and D2 group respectively. On the other hand, any emetic episodes were not observed in 04 group. At extent of sedation score, all experimental animals especially including the animals in D1 group were highly sedated at 15 minutes after administration of xylazine hydrochloride. Hematological and blood chemical values showed normal ranges pre- and post-experiment. We concluded that prior treatment with 4 mg/kg of dexamethasone hardly caused xylazine-induced emesis without disturbing the sedative effect of xylazine in dogs.

Analysis of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Shaped Steel with Tension Softening Behavior (인장연화거동을 고려한 강섬유 보강 초고성능 콘크리트 바닥판과 역T형 강재 합성보의 휨거동 해석)

  • Yoo, Sung-Won;Yang, In-Hwan;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.2
    • /
    • pp.185-193
    • /
    • 2015
  • Ultra high performance concrete (UHPC) has been developed to overcome the low tensile strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.

Fundamental Study for Extension of Application of Recycled Concrete Aggregate: Spun High Strength Concrete (순환골재의 사용성 확대를 위한 연구: 원심력콘크리트로의 적용)

  • Sim, Jong-Sung;Park, Cheol-Woo;Park, Sung-Jae;Kim, Hyun-Jung;Kim, Taeg-Wang;Lee, Man-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.103-112
    • /
    • 2006
  • Along with recent improvement of recycling technique, the quality of the recycled concrete aggregate have become very competitive to the natural concrete aggregate. Therefore, a practical use of the recycled concrete aggregate may be possible for structural members. Majority studies about the recycled concrete aggregate was emphasized a limitation of fundamental study concerned with a strength characteristics and durability of the recycled aggregate concrete, there is use for the structural members. Therefore, for the extension of application of recycled concrete aggregate, this investigation verifies the strength characteristics recycled concrete aggregate of the spun-concrete products with various coarse and fine recycled aggregate replacement ratio(coarse recycled aggregate: 0%, 20%, 40%, 60%, 100%; fine recycled aggregate: 0%, 30%, 60%, 100%) and with addition of cellulose fibers(0%, 0.01%, 0.03%, 0.05%, 0.08%). From the test results, The strength of spun concrete used with recycled aggregate [NR specimen], was measured as 72MPa, was found to be very approximately to the strength of spun concrete used with the natural aggregate(NN specimen), was measured as 74MPa, when only fine aggregate was replaced with the recycled. Therefore, the fine recycled concrete aggregate can be successfully used in the spun high strength concrete product. The compressive strength of all specimens used the specialty cellulose fiber were measured as about 70M Pa, however, the increasement of the specialty cellulose fiber content is showed to decrease compressive strength of spun concrete. Therefore, it is anticipated that the specialty cellulose fiber can be applied to the various spun concrete products.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

Effect of freezing and thawing on the drainage system for leakage treatment (유도배수공법에서 동결융해의 영향)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.1059-1075
    • /
    • 2017
  • The objective of this study was to evaluate the freezing and thawing resistance of the existing drainage system for leakage treatment of underground concrete structures operating in cold regions. The freezing and thawing test was conducted on 4 types of drainage system specimens to evaluate the freezing and thawing resistance of the drainage system. The freezing and thawing resistance was evaluated on 4 types of Hotty-gel, as a waterproofing material, connection methods and on two methods to fix the drainage board with Hotty-gel on the surface of cement concrete specimen. One cycle of the freeze-thaw testing was 48 hours (24 hours of freezing and 24 hours of thawing), and the temperatures of freezing and thawing were at $-18^{\circ}C$ and $10^{\circ}C$, respectively. Among the 4 types of Hotty-gel connection methods, leakage occurred after 28 cycles (8 weeks) of freeze-thawing only in the Hotty-gel connection method with the 'V' groove applied to the corner of the drainage board. No leakage occurred in the 3 types of Hotty-gel connection methods. In two fixing methods, leakage occurred in the method of fixing the drainage board on the cement concrete specimen using the washer, screw and plastic wall plug. Leakage occurred at one point after 10 cycles (3 weeks) of freezing and thawing. After 28 cycles (8 weeks) of freezing and thawing, leakage point increased to 5 points. As time passed, the leak point was not increased, but the amount of leakage was increased at each leak point. The Hotty-gel connection method with cross-sectional diagonal shape was evaluated to be the highest in the production efficiency considering the production time and manufacturing method of the Hotty-gel connection shape. In the construction efficiency considering the construction time and construction method, the fixing method of air nailer, fixed nail and washer was superior to that of the washer, screw and plastic wall plug.

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

EFFECT OF FLUORIDE IN NATURAL POLYMER ON ENAMEL DEMINERALIZATION (천연고분자 화합물을 이용한 불소겔이 법랑질 탈회에 미치는 영향)

  • Kim, Ji-Yeon;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.35-43
    • /
    • 2010
  • We have developed a sodium fluoride containing gelatin and methyl cellulose gel. Cariostatic abilities of those gel were investigated and compared with APF gel and fluoride varnish($Cavityshield^{TM}$). We prepared the bovine tooth samples and divided into two surface, control side and experimental side in same specimen for exclusion of difference between specimens. The experiment was consisted of 4 groups : (I) APF gel : (II) $Cavityshield^{TM}$ : (III) Gelatin F gel : (IV) Methyl cellulose F gel Decalcification were produced by placing each specimen into artificial acidic solution(pH 4.0) for 72 hours. Surface microhardness were measured and depth of demineralization lesion were measured by polarizing light microscope. The results were as follows: 1. The difference of VHN between control and experimental side is smallest in group I (p<0.05). 2. The largest difference was shown in group II (p<0.05). 3. There were no significant difference between group III and IV in microhardness test (p>0.05). 4. The difference of lesion depth is smallest in group I (p<0.05). 5. There were no significant difference between group II, III and IV in lesion depth (p>0.05). The result of the present study indicate that the fluoride containing gelatin and methyl cellulose gel is more effective than APF gel and is similar to fluoride varnish application for prevention of demineralization.

Residual Consistency and Interrelationship Estimation of PCDDs, PCDFs, Dioxin-like PCBs in Colostrum of Primipara and Multipara (초산부, 경산부 초유 중 PCDDs, PCDFs, dioxin-like PCBs의 축적수준 및 상관성 평가)

  • We, Sung-Ug;Kim, Ki-Ho;Cho, Yu-Jin;Cho, Bong-Hui;Park, Sang-Ah;Baek, In-Cheon;Kang, Seong-Hoon;Yoon, Cho-Hee;Min, Byung-Yoon
    • Journal of Life Science
    • /
    • v.20 no.7
    • /
    • pp.1078-1085
    • /
    • 2010
  • Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) are bioaccumulative chemicals that are considered to be toxic contaminants based on several epidemiological studies. These chemicals in colostrum were investigated and estimated for their residual consistencies by maternal characteristics like parity and maternal ages. Test subjects were healthy primipara and multipara mothers with a mean age of 31.5 (S.D=3.6) in 2007. Seven isomers of PCDDs, 10 of PCDFs, 4 of non-orthopolychlorinated biphenyls(non-ortho PCBs) and 8 of mono-orthochlorinated polychlorinated biphenyls (mono-ortho PCBs) were analyzed by HRGC/HRMS. From the analyzed data, the mean level of total WHO-TEQs was 9.41 pg TEQ/g lipid, which is significantly lower than the level found in individuals from other countries. The main contributors to the total WHO-TEQs with increasing percentages were 2,3,4,7,8-PeCDF, 1,2,3,7,8-PeCDD and 3,3',4,4',5-PCB (#126), and they accounted for more than 60% of the total WHO-TEQs. PCDFs concentrations and total WHO-TEQs were negatively associated with parity (p<0.05), and maternal age was positively associated with total WHO-TEQs (p<0.01). However, the associations with body mass index (BMI) and fish intake during pregnancy were not significant. These results were suggested that parity and maternal age are an important factor affecting the concentrations of PCDD/DFs and dl-PCBs in these specimens.

Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Steel Girder (강섬유로 보강된 초고성능 콘크리트 바닥판과 역T형 강거더 합성보의 휨거동 실험)

  • Yoo, Sung-Won;Ahn, Young-Sun;Cha, Yeong-Dal;Joh, Chang-Bin
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.761-769
    • /
    • 2014
  • Ultra high performance concrete (UHPC) has been developed to overcome the low strengths and brittleness of conventional concrete. Considering that UHPC, owing to its composition and the use of steel fibers, develops a compressive strength of 180 MPa as well as high stiffness, the top flange of the steel girder may be superfluous in the composite beam combining a slab made of UHPC and the steel girder. In such composite beam, the steel girder takes the form of an inverted-T shaped structure without top flange in which the studs needed for the composition of the steel girder with the UHPC slab are disposed in the web of the steel girder. This study investigates experimentally and analytically the flexural behavior of this new type of composite beam to propose details like stud spacing and slab thickness for further design recommendations. To that goal, eight composite beams with varying stud spacing and slab thickness were fabricated and tested. The test results indicated that stud spacing running from 100 mm to 2 to 3 times the slab thickness can be recommended. In view of the relative characteristic slip limit of Eurocode-4, the results showed that the composite beam developed ductile behavior. Moreover, except for the members with thin slab and large stud spacing, most of the specimens exhibited results different to those predicted by AASHTO LRFD and Eurocode-4 because of the high performance developed by UHPC.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.