• Title/Summary/Keyword: test results

Search Result 71,196, Processing Time 0.071 seconds

Evaluation of Soil Properties using Pressuremeter Test (공내재하시험을 이용한 지반정수 평가)

  • 한상연;장서만;전성곤;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

An On-Chip Test Clock Control Scheme for Circuit Aging Monitoring

  • Yi, Hyunbean
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.71-78
    • /
    • 2013
  • In highly reliable and durable systems, failures due to aging might result in catastrophes. Aging monitoring techniques to prevent catastrophes by predicting such a failure are required. Aging can be monitored by performing a delay test at faster clocks than functional clock in field and checking the current delay state from the test clock frequencies at which the delay test is passed or failed. In this paper, we focus on test clock control scheme for a system-on-chip (SoC) with multiple clock domains. We describe limitations of existing at-speed test clock control methods and present an on-chip faster-than-at-speed test clock control scheme for intra/inter-clock domain test. Experimental results show our simulation results and area analysis. With a simple control scheme, with low area overhead, and without any modification of scan architecture, the proposed method enables faster-than-at-speed test of SoCs with multiple clock domains.

A Study of HFC Network quality as BcN(Broadband convergence Network) access network. (광대역통합망 구축을 위한 HFC망의 활용 가능성 연구)

  • Kim, Tae-Woong;Chung, Moo-Il;Kim, Hong-Iq;Im, Joon-Soon;Park, Sung-Kwon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.167-170
    • /
    • 2005
  • We performed field test and analyzed results of field test in variable HFC(Hybrid Fiber Coaxial) network environments. And we investigated whether the test results is satisfied in DOCSIS(Data-over-Cable Service Interface Specification) 2.0 and OpenCable standard. Also, we propose HFC improvement problem for HFC Network quality as BcN(Broadband convergence Network) access network. We tested three sample areas. The sample areas represent various type of SO(System Operator) in korea. The field test was to measure signal level about digital channels. In results of multiple digital channels, in case of "Equalizer ON", we could be obtained very good test results. The results of field test were shown in satisfying recommended values in DOCSIS 2.0 and OpenCable. So, we could have confidence through field test that BcN will be possible to be adapted to environment of korea HFC network.

  • PDF

Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests (수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구)

  • Lee, Hojun;Kim, Ki-Eun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

A Study of Dichotic Listening Using the TOEIC Listening Test

  • Lee, Myung-Sook;Cha, Kyung-Whan
    • Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.121-132
    • /
    • 2006
  • The purpose of this research was to investigate dichotic listening, that is, whether the left and right ears have different functionalities in actual listening. Unlike previous studies, which used short words or a list of two or three numbers, these researchers investigated more comprehensive listening ability using the Toeic listening test. Sixty-three university students participated in this study. The subjects took three tests in total: one using only the right ear, another using the left ear, and the third using both. T-analysis of SPSS on the data revealed that there is a significant difference between the test results with only the right or left ear and the ones with both ears. So we cannot find right-ear priority in this study. We can see that in comprehensive listening, right hemisphere plays an important role as well as left hemisphere. When grouped according to language ability, test result of low group is the same as the total test result. However, in high group there is no significant difference between the test results with left ear and the results with both ears in high group. In mid group there is no significant difference between the test results with right ear and the results with both ears. The different functionalities of left and right ears and suggestions for future research are presented.

  • PDF

Comparision Analysis of Model Test for Prediction of Uplift Resistance in the Reclaimed Land Greenhouse Foundation (간척지 온실기초 나무말뚝의 인발저항력 예측을 위한 실내모형시험 결과 비교·분석)

  • Song, Chang Seob;Kim, Myeong Hwan;Jang, Ung Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.2
    • /
    • pp.45-52
    • /
    • 2016
  • The object of this paper was to evaulate modified proposed design equation in model test result in order to estimate uplift-resistance of timber pile of reclaimed land greenhouse foundation. Uplift resistance result of model test was increased to according to increased of contact area. Uplift-resistance result of field test tend to lineary increased to according to increased of embedment depth and contact area. Results of field uplift-resistance was evaluate compare with modified proposed design equation results of model test and Effective stress method. As the Effective stress method tend to underestimate, modified proposed design equation results of model test tend to similar type. As the contact area increase, difference between field uplift-resistance results and modified proposed design equation results of model test was considered uplift-speed.

Knee extension test for assessing hamstring flexibility (넓적다리뒤근육의 유연성 측정을 위한 무릎폄 검사)

  • Wootaek Lim
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.1
    • /
    • pp.31-40
    • /
    • 2023
  • Hamstring flexibility is an important factor that affects muscle performance of the lower extremities and is closely associated with sports injuries. Therefore, evaluation of flexibility is important in clinical practice. Results of evaluation are determined by types of tests and cut-off values used; therefore, accurate and detailed understanding of these is necessary before examination. Although the straight leg raise and sit and reach tests are used to evaluate hamstring extensibility, structures including the nerves, fascia, and other muscles can significantly confound the results of these tests. The knee extension test is performed at 90° of hip flexion to minimize the posterior pelvic tilt that occurs during the straight leg test. The knee extension test is most recommended for selective evaluation of hamstring flexibility. The knee extension test is classified into active and passive tests. The cut-off value is usually set at 20° for the active and at 10° for the passive knee extension test. Although a strong association is observed between the two tests, the active knee extension test is preferred in clinical practice because it can be performed by a single examiner, which serves as an advantage. Age, sex, and warm-up exercise tend to affect flexibility; therefore, results should be interpreted with caution. Detailed understanding of each flexibility test is important for reliable evaluation.

A Study on Prediction of the Liquefaction Behavior of Saturated Sandy Soils Using DSC Constitutive Equation (DSC구성방정식을 이용한 포화사질토의 액상화 거동 예측)

  • 박인준;김수일;정철민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.201-208
    • /
    • 2000
  • In this study, the behavior of saturated sandy soils under dynamic loads - pore water pressure and effective stress - was investigated using Disturbed State Concept(DSC) model. The model parameters are evaluated from laboratory test data. During the process of loading and reverse loading, DSC model is utilized to trace strain-hardening and cyclic softening behavior. The procedure of back prediction proposed in this study are verified by comparing with laboratory test results. From the back prediction of pore water pressure and effective mean pressure under cyclic loading, excess pore water pressure increases up to initial effective confining pressure and effective mean pressure decrease close to zero in good greement with laboratory test results. Those results represent the liquefaction of saturated sandy soils under dynamic loads. The number of cycles at initial liquefaction using the model prediction is in good agreement with laboratory test results. Therefore, the results of this study state that the liquefaction of saturated sandy soils can be explained by the effective tress analysis.

  • PDF

Correlation of Piezocone Dissipation Results and Compression Index (피에조콘 소산결과와 압축지수의 상관관계)

  • Park, Young-Hwan;Kang, Beong-Joon;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1204-1211
    • /
    • 2008
  • Compression index is one of the important characteristic numbers in soft soil engineering. Since 1940's, many researchers have suggested various practical solutions to define the compression index of clay using other soil properties. But, these results are only can give us an outline of soft soil behavior. In this study, the relationships between pore water pressure dissipation test results and compression index were suggested using comparison results of both tests. This relationships are based on basic concept of consolidation phenomena, essential difference between pore water pressure dissipation test and consolidation test, and disagreements between theoretical time factor and real time factor. To identify proportional factor of proposed equation, Geotechnical investigation results of Kwang-Yang(KY) site and Busan New Port(BN) site were used. The proportional factor was 0.0031 from 20 to 50% of consolidation rate where correlation parameter($R^2$) is 0.9051.

  • PDF