• Title/Summary/Keyword: test results

Search Result 71,196, Processing Time 0.074 seconds

Study on the Analysis of Failure Cause and Determination of Life Test Mode of Capsule (축열조 캡슐 고장원인 분석과 수명시험 모드 결정에 관한 연구)

  • Kang, Bosik;Lee, Yongbum;Jung, Dongsoo;Lee, Chungsung
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.260-270
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the life of the capsule, which is a core part of the heat storage cooling system. This paper will develop a life test mode that can reproduce environment conditions through the analysis of capsule shrinkage and expansion characteristics. Methods: In order to determine the life test mode of the capsule, this paper analyzed the case of field failures and analyzed the deformation characteristics according to the pressure fluctuation of the capsule. The method to find out whether the field failure and deformation analysis results are consistent is the testing with the construction of the repetition pressure test equipment and the thermal cycle test to reproduce the freezing and thawing characteristics. Results: In this study, failure mode analysis and analysis of freezing and thawing characteristics regarding to the capsule positions were completed. Based on this test & analysis results, this paper have been able to determine the main parameters for determining the life test mode, the freezing and thawing time. Conclusion: Determining the lifetime mode of the capsule can be used to improve the life and performance of the thermal storage system.

Rotordynamic Characteristics Analysis of Turbocharger Turbine for Spin Test (터보차져용 터빈의 스핀 테스트를 위한 로터다이나믹 특성분석)

  • Kim, Byung-Ok;Yang, Sung-Jin;Lee, Myung-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.91-95
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for the assembly rotor composed of turbine wheel, turbine shaft, connecting arbor, and flange & spindle in order to perform the spin test of turbocharger turbine. Prior to rotordynamic analysis, the 1st spin test was performed but the test was failed by excess vibration in the neighborhood rated speed. It is the reason for this fail that the separation margin between the rated speed and critical speed is not enough, confirmed by rotordynamic analysis results. Since then, the dimension of turbine shaft was modified and the critical speeds were again reviewed for modified assmebly rotor. In results, the separation margin between the rated speed and critical speed is over 20% and then the 2nd spin test was performed successfully. In preparing spin test for turbine, compressor wheels and etc., the geometry design of connecting arbor and dimension of rough machining should be reviewed by considering rotordynamic results, and the separation margin should be enough for successful spin test.

The discrete element method simulation and experimental study of determining the mode I stress-intensity factor

  • Shemirani, Alireza Bagher;Haeri, Hadi;Sarfarazi, Vahab;Akbarpour, Abbas;Babanouri, Nima
    • Structural Engineering and Mechanics
    • /
    • v.66 no.3
    • /
    • pp.379-386
    • /
    • 2018
  • The present study addresses the direct and indirect methods of determining the mode-I fracture toughness of concrete using experimental tests and particle flow code. The direct method used is compaction tensile test and the indirect methods are notched Brazilian disc test, semi-circular bend specimen test, and hollow center cracked disc. The experiments were carried out to determine which indirect method yields the fracture toughness closer to the one obtained by the direct method. In the numerical analysis, the PFC model was first calibrated with respect to the data obtained from the Brazilian laboratory test. The crack paths observed in the simulated tests were in reasonable accordance with experimental results. The discrete element simulations demonstrated that the macro fractures in the models are caused by microscopic tensile breakages on large numbers of bonded particles. The mode-I fracture toughness in the direct tensile test was smaller than the indirect testing results. The fracture toughness obtained from the SCB test was closer to the direct test results. Hence, the semi-circular bend test is recommended as a proper experiment for determination of mode-I fracture toughness of concrete in the absence of direct tests.

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

Validating the Berg Balance Test for Patients with Parkinson's Disease (파킨슨병 환자에서 낙상군과 비낙상군에 대한 버그균형검사의 타당도)

  • Cho, Gyu-Hang;Woo, Young-Keun;Hwang, Su-Jin
    • PNF and Movement
    • /
    • v.9 no.3
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate the criterion-related validity of the Berg balance test between fallers and non-fallers in individuals with Parkinson's disease. Methods : Thirty-one patients were recruited for this study. Their initial diagnosis had been made on average $30.1{\pm}10.1$ years earlier. Score of Berg balance test showed significant correlations with indicators of motor functioning and daily living capacity. Berg balance test score was inversely associated with the unified Parkinson's disease rating scale-motor score, and Schwab and England activities of daily living rating scale. Results : In all 3 correlations, lower scores on the Berg balance test correlated with higher unified Parkinson's disease rating scale-motor scores. Results support the criterion-related validity of the Berg balance test. Conclusion : Our research results agree with other published research in suggesting that the Berg balance test may be used as a screening tool and ongoing assessment tool for patients with Parkinson's disease.

Analysis of the Causes of Cracks in Rocket Propellant in Thermal Cycling Test (로켓탄 추진기관 온도반복시험 균열 원인분석)

  • Bak, Jin Man;Park, Soon Woo
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.4
    • /
    • pp.735-749
    • /
    • 2023
  • Purpose: The purpose of this study is to derive solutions and prevent similar cases from occurring by analyzing the causes of cracks found in temperature cycling tests of rocket motor. Methods: By combining the results of the current state confirmation test, non-destructive test, domestic and foreign rocket motor comparison test, cutting test, and adhesion test according to the number of times to apply mold release agent, a Cause and Effect Diagram analysis was performed to derive the cause of cracks. Results: Through this study, 26 factors that could cause cracking in rocket motors during temperature cycling tests were identified. Through various additional test results, a total of five causes were identified, including chemical and structural design of the joint between the propellant and stress relief insert, omission of procedure in the manufacturing procedures, natural aging due to temperature, and load accumulation due to temperature changes. The fundamental cause was confirmed to be insufficient consideration of the release properties of the propellant and stress relief insert. Conclusion: During the design process, it was confirmed that this could be solved by structurally or chemically designing the insert so that it does not combine with the propellant, or by applying a mold release agent during the manufacturing process.

Captive Model Test of Submerged Body Using CPMC (몰수체의 CPMC 구속모형시험)

  • Kim, Yeon-Gyu;Yun, Kun-Hang;Kim, Sun-Young;Kim, Dong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.4
    • /
    • pp.296-303
    • /
    • 2012
  • The captive model test of submerged body using CPMC(Computerized Planar Motion Carriage) was carried out at the Ocean Basin of KORDI/MOERI. The target model is a submarine with general hullform. The forces and moments acting on the submerged body were measured by 6-axis waterproof gage. The oblique motion test and turning test were carried out in horizontal and vertical planes of the model. Maneuvering coefficients and derivatives were obtained from the test results. The stability indices in horizontal and vertical planes were obtained by using maneuvering derivatives. In this paper the introduction of test equipment and test results are presented.

Durability Characteristics of RC containing Different Chloride Contents based on Long Term Exposure Test and Accelerated Test (장기폭로시험과 촉진시험에 근거한 염화물 함유량에 따른 철근콘크리트의 내구특성)

  • 권성준;송하원;신수철;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.759-762
    • /
    • 1999
  • The concrete structures possessing good structural integrity can face durability problems due to deteriorations of concrete structures under various environmental conditions. The durability problems weaken the structural integrity in the long run. Especially, the excessive use of sea sand causes serious reinforcement corrosion and carbonation in concrete structures. An accelerated test is often used to predict deterioration as a qualitative measure, but without long term exposure test results or understanding of the relationship between the accelerated test and the long term exposure test, the accelerated test result alone can not be used effectively as a quantitative measure. In this paper, a methodology is proposed to predict the long term deteriorations, based on the result of the short-term accelerated test, of concrete containing different contents of chloride ions. Then, the correlation between two results on the steel corrosion ratio and the carbonation depth is analyzed for concrete with different chloride contents.

  • PDF

A Study on Friction and Wear Characteristics of Sintered W/C-35%Ni Tappets for Diesel Engine Application (디젤엔진용 소결(W/C35%Ni) 태핏의 마멸거동에 관한 연구)

  • 류병진;오세일;박맹로;양승호
    • Tribology and Lubricants
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2000
  • Abstract- In this paper tribological characteristics of solid and liquid phase sintered W/C-35%Ni tappets were investigated. Three test methods were performed to investigate the wear and surface damage mechanism of sintered tappets. First, block-on-ring wear test was performed to investigate the wear characteristics under pure sliding condition. Second, simplified cam and tappet tests (called component wear test hereafter) were carried out to simulate the real contact history of cam and tappet. Also, after the test, contact surfaces were analyzed with scanning electron microscope to study the wear mechanism. As a final screening, engine dynamo tests were performed. Results showed that in the block on ring sliding wear test, solid phase sintered specimens showed superior wear resistance to liquid phase sintered specimens. The component wear tests and engine dynamo tests also showed the same results. Therefore, in these tests, solid phase sintered tappet material revealed superior wear resistant properties to liquid phase sintered one.

Evaluation of Weathered Granite Soil l Geogrid Friction Properties and Pull out Test (화강 풍화토/지오그리드 인발시험 및 마찰특성 평가)

  • 조삼덕;김진만
    • Geotechnical Engineering
    • /
    • v.12 no.4
    • /
    • pp.87-100
    • /
    • 1996
  • The pull -out test has been used to investigate the friction properties between soil and grid type geosynthetics which is useful to measure the passive bearing resistance as well as the skin friction. In this paper, the friction properties between geogrid and a weathered granite soil are investigated by performing various pull-out tests. From the test results, a rational pull out test equipment and test method is suggested by evaluating the effects of major factors (such as geogrid width, location of soil box facing, vertical loads and pulll -out displacement rate, etc.) on pull -out test results.

  • PDF