• Title/Summary/Keyword: test facility

Search Result 1,836, Processing Time 0.032 seconds

Design of the Full-Scale Fire Safety Evaluation Facility for Railroad Vehicle Fire (철도차량 실대형 화재안전 성능평가 장치 설계)

  • Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.222-225
    • /
    • 2008
  • To prove a lot of technical difficulties related to the safety management of a railroad fire effectively, we design for the full-scale fire test facility of the railroad vehicle. It will be consist of major 3 part - duct system with smoke cleaning system, measuring section and gas analysis system. The CFD simulation was also carried out to design of the hood and duct system optimization. The results will be help for basic research of the railroad fire safety.

  • PDF

Hydrogen Behavior at a Subcomparment in The Containment Building

  • Lee, U.J.;Park, G.C.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.495-500
    • /
    • 1997
  • For hydrogen management in severe accidents with degraded nuclear core of PWR's, several experiments have been performed in the SNU hydrogen mixing facility. The objectives are understanding the extent of hydrogen mixing and analyzing the effects of factors which dominate uniform or non-uniform mixing at compartments in the containment building. The facility represents on a 1/11th linearly scaled model of the YGN unit 3&4, hydrogen was simulated by helium. Because there are the gaps between safety injection tank and compartment layers in the containment, the test facility was constructed in three dimentinal mode for analyzing of mixture behavior through the gaps. From the experimental results we could conclude that overall hydrogen concentration distributed uniformly in the free volume of the test compartment, but fluctuated in the gaps. This paper is focused on experimental result from several experiment.

  • PDF

A Space Usage and User Evaluation of Community Facility in High rise Mixed-use Apartment (초고층 주상복합아파트 커뮤니티시설의 공간실태 및 평가에 관한 연구)

  • Noh, Yi-Kyung;Hwang, Yeon-Sook
    • Journal of the Korean housing association
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2007
  • The objective of this study is to analyze the space usage and user evaluation of community facility in High rise Mixed-use Apartment. This study was conducted case study and questionnaire survey. Four High rise Mixed-use Apartments built since 2000 were chosen for case study and 166 residents were collected for questionnaire survey. The frequency, percentage, mean, t-test and F-test were executed through SPSS for Win 12.0 statistics package program. The types of community facilities of High rise Mixed-use Apartments were consisted of sports, child care/study, information sharing, leisure/cultural facilities. The usage percentage of community facilities increased since the residents have moved to their current residence of High rise Mixed-use Apartments from their previous residence. The most satisfactory facility was sports facilities. The satisfaction of community facilities showed high in general. The satisfaction of community facilities was significant with gender and age.

LOx/kerosene Sub-scale LRE Firing Test Facility (액체산소/케로신 소형로켓엔진 연소시험설비)

  • Kim Seung-Han;Lim Byoung-Jik;Han Yeoung-Min;Seol Woo-Seok;Lee Soo-Yong;Moon Il-Yoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.166-169
    • /
    • 2004
  • This paper describes the design, installation and certification activity of a combustion test facility of subscale thrust chambers propelled by pressure-fed liquid oxygen and kerosene, and suggests major key issues considered at each development stage of the facility

  • PDF

A Study on the evaluation of the auditory guide facility under emergency situation (비상시 청각형 유도시설의 유도성능 평가에 관한 연구)

  • Na, Wook-Jung;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

The characteristics of thermo-acoustic oscillation happened at PTA-II of KSR-III rocket (KSR-III Rocket 종합 추진 시험 설비에서 발생한 열-음향학적 진동의 특성)

  • S. Cho;S. Kang;Kim, Y.;I. Cho;S. Oh;Lee, D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.364.2-364
    • /
    • 2002
  • Thermoacoustic oscillation, which stems from phase correlation between unsteady heat release and acoustic fluctuation, can cause severe vibration and incite the excessive local heat transfer inside the rocket engine. It is very important to understand and prevent this phenomenon in the way of rocket engine development. In this study, the propulsion test facility of KSR-III, which is the first liquid propellant rocket developed by KARI, will be introduced. and the characteristics of thermoacoustic ocillation occurred at the facility will be examined.

  • PDF

Modificaion and Performance Test for improving ability of Supersonic/Hypersonic Wind Tunnel(MAF) (초음속/극초음속 풍동(MAF)의 성능 향상을 위한 개조 및 검증)

  • Choi, Won-Hyeok;Seo, Dong-Su;Lee, Jae-Woo;Byun, Yung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.717-722
    • /
    • 2010
  • Supersonic/Hypersonic wind tunnel is a facility which is intended to test and to observe the physical phenomena around a model by creating supersonic flow in the test section. In designing an airplane, the wind tunnel test is demanded to analyzing aerodynamic characteristics of the model without making a prototype. In this research, the model aerodynamic facility(MAF) is modified for the purpose of increasing running time and its functionality. New pneumatic valves for remote control was installed for safety requirement, and new air tanks was installed on MAF as well. A pipe system is also modified to use those new valves and tanks, and the ceiling and side glasses of the test section are switched to ones with the larger surface area. After the MAF modification, a test is performed at Mach 2, 3 and 4. In this test, shadow graph technique, one of the flow visualization methods, is used to visualize supersonic flow field. The pressure in the settling chamber and working section at Mach 2, 3 and 4 was measured in each case. As a result, the possible model size and running time are obtained.

  • PDF

Feasibility Study of a Corrugated Steel Protective Structure for Ammunition Test Facility (탄약시험장의 강재 방호구조물 적용성 분석 연구)

  • Han, Jae Duk;Kim, Donghee;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.671-679
    • /
    • 2022
  • Harmful factors such as shock waves and fragments are generated at domestic ammunition testing sites and military shell shooting training sites due to frequent shooting and explosion tests. As a result, complaints from local residents are rapidly increasing, and there is a high risk of damage to facilities and human life. The recently constructed ammunition test site built a test facility for firing artillery and rocket propulsion in a narrow area with a radius of 300 m due to site restrictions, but damage to the facility is accumulating because there is no adequate protective structure. Therefore, in this study, quantitative data on harmful factors such as noise, vibration, shock wave, and thermal effect generated between artillery firing and rocket propulsion tests were measured, and explosion pressure characteristics were analyzed to design a protective structure, and use Autodyn to protect performance. to perform verification.

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

Study on Usability and Structure of the Mechanical Pencil (샤프펜슬의 사용편의성과 그 구조에 관한 연구)

  • 윤형건
    • Archives of design research
    • /
    • v.15 no.3
    • /
    • pp.63-72
    • /
    • 2002
  • I made the three main estimated head about the facility of mechanical pencil which we always use in normal days. The head are these, the first is apparent usability by experiment, the second is the feeling when grasping, the third is the feeling when writing. After making the head, 1 selected the head which give the effect to the facility and make sure the interaction between heads by the method of actual test with 36 samples. After this test, 1 can find that there is no high interaction between the facility and the intuitively feeling by experiment. It's because the expectation which was made by experiment for the facility is higher than the real. but there is high interaction between the feeling of wearing and the feeling of writing. The mechanical pencil which has good facility is that the total length is long(169mm), the thickness is big($\Phi$8.5mm), the weight is little bit heavy(21.4g), the intersection is not circle, the surface where is hold by fingers has across grooves, and the body is glossy.

  • PDF