• 제목/요약/키워드: test facility

검색결과 1,829건 처리시간 0.029초

Combined De-NOx Process with $NH_3$ SCR and Non-thermal Plasma Process for Removing NOx and Soot from Diesel Exhaust Gases

  • Chung, Kyung-Yul;Song, Young-Hoon;Oh, Sang-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.657-665
    • /
    • 2003
  • Combined De-NOx Process in which $NH_3$ SCR (Selective Catalytic Reduction) and non-thermal Plasma Process are simultaneously used, has been investigated with a pilot test facility. The pilot test facility treats the combustion flue gases exhausted from a diesel engine that generates 240 kW of electrical power. Test results show that up to 80 % of NOx (NO and NO2) can be removed at 100 - $200^{\circ}C$. None of conventional De-NOx techniques works under such low temperature range. In addition to NOx. the Pilot test results show that soot can be simultaneously treated with the present non-thermal plasma technique. The present pilot test shows that the electrical power consumption to operate the non-thermal plasma reactor is equivalent to 3 - 4 % of the electrical power generated by the diesel engine.

원자로냉각재펌프의 완전특성 시험 (Complete Characteristics Test for a Reactor Coolant Pump)

  • 윤의수;유일수;박무룡;황순찬;김수원;임영철;오인균;강민호;최원철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.671-674
    • /
    • 2011
  • 한국기계연구원에서는 원자로냉각재펌프의 완전특성을 시험할 수 있는 시험 설비를 구축하였다. 이 설비는 유량은 최대 2,000 m3/hr, 동력은 최대 132 kW까지 펌프 및 수차의 시험이 가능하다. 본 논문에서는 완전특성 시험장치 및 시험방법, 이를 이용한 원자로냉각재펌프의 시험결과를 소개하고자 한다.

  • PDF

터보펌프 시스템용 베어링/실 시험설비 개발 (Development of bearing/sealing test facility for turbopump system)

  • 우관제;김경호;우유철
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2003
  • 베어링/실 시험설비 (BST)는 다양한 매체 (물, 액체질소, 액체산소)에서 액체로켓 엔진의 터보펌프를 위한 베어링과 실을 시험하기 위한 장비이다. 베어링 성능특성 시험은 베어링을 통과하는 냉각 유량과 축 방향 및 반경방향의 하중을 모사하여 시험이 수행된다. 실 시험의 목적은 실을 통과하는 누수량과 시간에 따른 누수량의 변화를 결정하기 위함이다.

  • PDF

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

고속도로 비점오염저감시설의 효율적 적용 방안 (Effective Application Method for Pollution Mitigation Facility of Highway Runoff)

  • 이용복;최상일;정현규;배세달;정선국
    • 한국토양비료학회지
    • /
    • 제44권6호
    • /
    • pp.1264-1271
    • /
    • 2011
  • To build environmentally friendly highways, we testes suitability for unique characteristics of pollution mitigation facility around the highways by evaluating optimal selections and implementation methodologies to minimize loan of non-point pollution substances into water-ways. To do this we categorized EIA target highways into three types ; big drainage basin, small drainage basin, and bridge section as to minimize non-point pollution of highway runoff. The terms of selected facility test based on the Natural and Manufactured Treatment Device were removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, maintenance convenience, and the final mitigation facility.

단순 시설입지 선정문제에 대한 쌍대기번 휴리스틱 (A Dual-Based Heuristic Algorithm for the Simple Facility Location Problem)

  • 노형봉
    • 한국경영과학회지
    • /
    • 제12권2호
    • /
    • pp.36-41
    • /
    • 1987
  • This paper presents a heuristic algorithm for solving the simple facility location problem. Its main procedure is essentially of 'add' type, which progressively selects facilities to open according to a certain criterion derived from the analysis of the linear programming dual. Computational experience with test problem from the literature is presented.

  • PDF

가시설 안정성 검토에 관한 인천국제공항 시공 사례 연구 (Case Study for the Stability of Temporary Shoring Facilities at Inchon International Airport)

  • 최인걸;조현모;류승철
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 1999
  • This case study has been prepared to provide the practical data about construction of temporary shoring facilities (i.e. braced sheet pile excavation) and to utilize the case study information effectively for design and construction of future facilities. This case study includes information such as 1) installing measurement devices to monitor the deformation of the sheet pile walls and the subsoil in the vicinity after establishing the criteria for the sheet pile deflection; 2) monitoring the actual movement of the temporary facility after setting up the survey control standard (due to the movement of the temporary facility) : 3) inspecting the suitability of the temporary facility construction: and 4) analyzing and studying the result of the tension test after installing ground anchors.

  • PDF

담수화 설비 스프레이 노즐에 대한 실험적 연구 (An Experimental Study of Spray Nozzle Desalination Facility)

  • 신현경;주현태;박민호;박경민;김진영;임진영
    • 한국해양공학회지
    • /
    • 제20권1호
    • /
    • pp.26-31
    • /
    • 2006
  • Experimental research was undertaken to develop a domestic spray nozzle used on equipment for desalination. First, we made a test set-up in order to confirm nozzle efficiency of spray and distribution under different pressure conditions. Then, we found a maximum spray condition after verifying reliability of this facility. An optimum arrangement of the nozzle, based on the test result, was made using CATIA V5 and EXCEL.

TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY

  • Veronese, Fabio;Kozlowsk, Tomasz
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.719-726
    • /
    • 2012
  • The object of this work is the validation and assessment of the TRACE v5.0 code using the scaled test ATLAS1 facility in the context of a DVI2 line break. In particular, the experiment selected models the 50%, 6-inch break of a DVI line. The same experiment was also adopted as a reference test in the ISP-503. The ISP-50 was proposed to, and accepted by, the OECD/NEA/CSNI due to its technical importance in the development of a best-estimate of safety analysis methodology for DVI line break accidents. In particular, the behavior of the two-phase flow in the upper annulus downcomer was expected to be complicated. What resulted was the need for relevant models to be implemented into safety analysis codes, in order to predict these thermal hydraulic phenomena correctly.

철도차량 실대형 화재안전 성능평가 장치 설계 (Design of the Full-Scale Fire Safety Evaluation Facility for Railroad Vehicle Fire)

  • 유용호;김흥열
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.222-225
    • /
    • 2008
  • To prove a lot of technical difficulties related to the safety management of a railroad fire effectively, we design for the full-scale fire test facility of the railroad vehicle. It will be consist of major 3 part - duct system with smoke cleaning system, measuring section and gas analysis system. The CFD simulation was also carried out to design of the hood and duct system optimization. The results will be help for basic research of the railroad fire safety.

  • PDF