• Title/Summary/Keyword: test facility

Search Result 1,836, Processing Time 0.03 seconds

Seismic Performance Evaluation of the Li-Polymer Battery Rack System for Nuclear Power Plant (원자력발전소용 리튬폴리머 배터리 랙 시스템의 내진성능평가)

  • Kim, Si-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.13-19
    • /
    • 2019
  • After the Fukushima nuclear accident, a new power supply using a lithium polymer battery has been proposed the first time in the world as the safety of the emergency battery facility has been required. It is required to have the safety of the rack system in which the battery device is installed in order to apply the proposed technology to the field. Therefore, the purpose of this study is to evaluate the seismic performance of string and rack frame for lithium-polymer battery devices developed for the first time in the world to satisfy 72 hours capacity. (1) The natural frequency of the unit rack system was 9 Hz, and the natural frequency before and after the earthquake load did not change. This means that the connection between members is secured against the design earthquake load. (2) he vibration reduction effect by string design was about 20%. (3) As a result of the seismic performance test under OBE and SSE conditions, the rack frame system was confirmed to be safe. Therefore, the proposed rack system can be applied to the nuclear power plant because the rack system has been verified structural safety to the required seismic forces.

Analysis of Temperature and Probability Distribution Model of Frozen Storage Warehouses in South Korea (국내 식품냉동창고 온도분포 실태 및 확률분포모델 분석)

  • Park, Myoung-Su;Kim, Ga-Ram;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.199-204
    • /
    • 2019
  • This study aimed to generate a probability distribution model based on temperature data of frozen food storage facility as input variables for microbial risk assessment (MRA). We visited 8 food-handling businesses to collect temperature data from their cold storage warehouses. The overall mean temperature inside the storage facilities was $-20.48{\pm}3.08^{\circ}C$, with 20.4% of the facilities having above $-18^{\circ}C$, with minimum and maximum temperature values of -10.3 and $-25.80^{\circ}C$ respectively. Temperature distributions by space locations of natural and forced convection were $-22.57{\pm}0.84$ and $-17.81{\pm}1.47^{\circ}C$, $-22.49{\pm}1.05$ and $-17.94{\pm}1.44^{\circ}C$, and $-22.68{\pm}1.03$ and $-18.08{\pm}1.42^{\circ}C$ in the upper (2.4~4 m), middle (1.5~2.4 m), and lower (0.7~1.5 m) shelves, respectively. Probability distributions from the temperature data were obtained using the program @RISK. Statistical ranking was determined using goodness of fit to determine the probability distribution model. Our results show that a log-normal distribution [5.9731, 3.3483, shift (-26.4281)] is most appropriate for relative MRA conduction.

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Construct of uncontaminated underground reservoir test facility (청정지하저수지 시험시설의 구축)

  • Lee, Chang Seob;Park, Nam Sik;Jeong, Jae Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.328-328
    • /
    • 2016
  • 우리나라는 생활용수의 대부분을 지표수에 의존하고 있는 실정이다. 그러나 지표수는 가뭄과 같은 기상변화, 수질사고 등으로 물 공급의 안정성에 문제가 되기도 한다. 향후 기후변화는 가뭄의 빈도와 강도를 증대시킬 것으로 파악되므로 수질 및 수량의 문제를 더욱 악화시킬 것으로 예상된다. 이러한 문제점을 해결하기 위해 지표수를 대수층 내에 인공적으로 함양한 뒤 대수층의 자연정화 기능에 의해 여과된 양질의 청정원수를 생산하는 기술을 본 연구에서 현장에 실증 적용하는 시설을 구축하였다. 이러한 기술은 기존의 지하 대수층을 이용하는 강변여과 등이 갖는 장점을 취하고 단점을 보완하였으며 친환경적이며 지속가능한 용수공급뿐만 아니라 청정 원수 확보를 통해 정수처리비용을 절감, 장기간의 가뭄이나 지표수 수질사고 시에 비상용수 공급 등 기존 취수원들과 달리 많은 장점을 갖고 있는 대규모 청정지하저수지 시험시설이다. 청정 지하저수지 기술이 주로 적용되는 지역은 해안지역 또는 하구 델타지역을 대상으로 한다. 해안 또는 델타지역은 해수침투로 인하여 염지하수가 부존되어 있기 때문에 지하수자원 활용에 매우 제한적이다. 따라서 지표수(담수)를 전처리하여 대수층에 인공적으로 함양을 하여 염지하수 대수층 안에 담지하수(담수체)를 형성할 수 있다. 이는 염수와 담수의 밀도차에 의해 희석되지 않는 특성을 이용한 기술이다. 청정 지하저수지 시험시설은 크게 지표수 취수시설, 전처리시설, 주입정, 양수정, 운영시스템으로 나눌 수 있다. 주입정 및 양수정은 원형의 형태로 지하저수지 조성범위 중심부에 9개의 주입정과 외각에 8개의 양수정을 설치하였다. 시험시설의 운영 과정은 하천수를 취수하여 전처리시설에서 탁도를 제거한 후, 피압대수층 염지하수에 동력으로 주입을 한다. 이때 기존에 부존되어 있던 염지하수를 밀어내고 담수체 지하수 형성을 유도한다. 일정기간 주입을 통해 목표 담수체를 만들어 내면 양수정에서 담수를 취수하되, 대수층의 모래자갈층을 일정거리 이동하여 취수하는 방식이다. 즉, 하천수를 대수층에 함양하고, 일정거리를 이동하여 취수하는 ASTR 방식의 대체수자원 확보 기술이다. 시험시설은 통합운영센터를 통해 원격감시 및 각종 제어/계측을 실시하며, 모니터링된 자료는 운영시스템에서 관리한다. 본 연구시설에서는 대수층 주입, 관정폐색, 미생물/지화학 수질반응, 지하수모니터링, 지반변형 등이 주요 핵심 연구를 진행하고 있도록 시설을 구성하였다. 본 시험시설은 2015년 8월 착공하여 2016년 4월에 완공 예정이며, 2016년 3월부터 주입을 시작하여 6개월간 피압대수층에 주입을 실시하고 이후부터 주입과 양수를 병행할 계획이다.

  • PDF

A Study on the Development of Universal Design Evaluation System in the Public Space (공공공간의 유니버설디자인 평가체계 개발 연구)

  • Park, Cheongho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.2
    • /
    • pp.25-37
    • /
    • 2021
  • Purpose: The main purpose of this study is to develop an evaluation system using the weighted-values of various users and experts for the public space to apply Universal Design, and additionally to find out the commonalities and differences by comparing the importance of evaluation indicators between users and expert groups. Method: A one-sample t-test was conducted to verify that the components of the public space to universal design application are suitable as evaluation indicators, and AHP(analytic hierarchy process) was performed to derive weight-values for the evaluation system. Results: The importance-values for the total 23 facilities to be used as evaluation indicators were derived by multiplying the weighted-values of each sector, domain, and facility by the disabled, non-disabled, and experts. To summarize the results of overall importance-values derived from the AHP, The disabled showed high-rank weighted-values in facilities of building sector > park & recreation sector > cross domain and low-rank weighted-values for sidewalk and roadway domain. The non-disabled showed high-rank weighted-values in facilities of park & recreation sector > roadway domain > building sector > cross domain and low-rank weighted-values for sidewalk domain. Experts mainly showed high-rank weighted-values in the cross domain and in facilities related to entry and movement to the target space in all sectors and domains. However, it showed moderate importance-values in the sanitary space. The disabled who are restricted to movement have a high demand for universal design in buildings consisting of vertical moving line, and non-disabled people who are not limited to physical movement have a high demand for universal design in parks and recreation sector for increased leisure time. It means that experts are important to recognize the principles of making space because they value cross domain and the key spaces and facilities for suitable the purpose of use. In addition, it can be inferred that non-disabled people have a higher demand for safety than disabled people due to their high importance in roadway domain and facilities of safety and disaster prevention. Implications: The significance of this study is the establishment of a quantitative universal design evaluation system for public spaces considering the different perspectives of the disabled and the non-disabled.

Analysis of the Correlation between the velocity speed of High-Speed Railways and the Suppressing Effect of lateral Displacement of retaining wall according to the Arrangement of Stabilizing Piles (억지말뚝의 배치에 따른 흙막이의 수평변위 억제효과와 고속철도의 속도와의 상관성 분석)

  • Son, Su-Won;Im, Jong-Chul;Seo, Min-Su;Hong, Seok-Woo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • In urban areas, structures are installed deep underground in the lower part of the structure to utilize space. Therefore, a retaining wall is used to prevent earth pressure from the ground when constructing a structure. Due to the development of construction technology, retaining wall applied to excavation work are used to prevent danger such as falling rocks and landslides in temporary facilities when construction or retaining walls are installed. In general, the application of a retaining wall to a temporary facility during the embankment construction is the case of expanding an existing roads or railways. Therefore, it is necessary to study the retaining wall applied to the embankment construction such as the double-track site of the high-speed railway. In this study, two types of common one row H-pile retaining wall and two types of IER retaining wall were analyzed, and the stability of the retaining wall applied to the construction of double-track of the high-speed railway was analyzed. The earth retaining wall is a construction method that combines forced pile applied to the stabilization of the slope with the wall of the earth retaining wall. As a result of the analysis, the IER retaining wall had maximum lateral displacement of 19.0% compared to the type with H-plie installed only in the front while dynamic load was applied. In addition, the slower the speed of high-speed railway, the more displacement occurred, and the results show that more caution is needed when designing the ground in low-speed sections.

A study on the development of distribution simulator and simulation results for use in distribution automation system of IEC 61850 protocol (IEC 61850 프로토콜의 배전자동화시스템에 사용을 위한 배전시뮬레이터 개발과 시뮬레이션 결과에 관한 연구)

  • Kim, Jae-Hong;Oh, Jae-Gon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.95-102
    • /
    • 2022
  • It is a study for the evaluation of the stability of the distribution automation system for the expansion of renewable energy. Through the Renewable Energy 3020 Implementation Plan, the government plans to expand new renewable energy and convert it to participatory energy that improves the quality of life of the people by 2030. The government has set a target of 20% of domestic supply energy for renewable energy generation by 2030. It is planning to establish more than 95 percent of its new facilities with clean energy such as solar power and wind power. By expanding the supply of renewable energy, new energy businesses and distributed power industry were fostered, and short-distance, low-voltage, and small-scale power generation were rapidly expanded rather than large-scale power development in the past. Due to this demand, the importance of power distribution facility operation has emerged and the need for distribution automation system is increasing. This paper discusses the development of a power distribution simulator for the performance and function evaluation of power distribution automation systems and presents the results of an interlocking test with the power distribution automation system. In order to introduce an advanced system into the power distribution system, it is necessary to take advantage of the transmission and distribution system. The DNP3.0 protocol is used in the distribution system and the IEC61850 protocol is used in the transmission and distribution system. It was concluded that the functions and performance of operations were satisfied when these two protocols are mixed and used in the distribution automation system.

An Experimental Study on the Performance of Expandable Steel Pipe Pile (확장형 강관말뚝의 성능에 대한 실험적 연구)

  • Kim, Junghoon;Kim, Uiseok;Kim, Jiyoon;Kang, Minkyu;Choi, Hangseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Expandable steel pipe piles are installed by inserting expansion equipment to increase the cross-sectional area of steel pipes, which can improve the pile performance compared to micro-piles. In this paper, a hydraulic expansion device was developed to expand steel pipe piles in practice. A series of laboratory and field tests were conducted to verify the performance of the developed expansion device to expand steel pipes. The expansion capability and expandable range was evaluated by measuring the strain and expansion time at the maximum pressure of the hydraulic expansion device. The thinner steel pipe, the larger strain but longer expansion time required in the test. For example, the 4.0-mm-thick steel pipe showed strain reduction by 30% and a decrease in the required expansion time by 40% compared to the 2.9-mm-thick steel pipe. In addition, in-situ expansion tests were performed to verify the expandability of steel pipes under the ground, and the exhumed specimen showed clear expanded sections. The structural integrity was determined by comparing the material performance the original and expanded specimens.

An Analysis of the Current Status and Characteristics of Airborne Fungi in Indoor Air in Multi-Use Facilities Nationwide (전국 다중이용시설의 실내공기 부유 곰팡이의 현황 및 특성 분석)

  • Park, Yongsung;Kwon, Soonhyun;Park, Song-Yi;Kee, Sun-Ho;Yoon, Wonsuck
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.5
    • /
    • pp.282-289
    • /
    • 2022
  • Background: Airborne fungi are ubiquitous in the air and exposure to an airborne fungus can be a significant risk factor. The composition of fungi has been potentially important for human health, especially for respiratory diseases like asthma and atopic dermatitis. Therefore, we attempted to ascertain what kind of airborne fungi affect human health at a nationwide level. Objectives: This study was carried out to provide information on indoor fungi distribution at multi-use facilities throughout South Korea. Methods: We classified our data by region and public facility after collection, cultivation, and identification via the sequencing of the ITS (internal transcribed spacer) region. We investigated whether or not the proliferation of HaCaT cells was affected by the identified airborne fungi. Results: In our data, the most isolated airborne fungi by region were Penicillium spp (Seoul, Daegu), Periconia sp (Gyeonggi-do), Iprex sp (Gangwon-do), Phanerochaete sp (Busan), Bjerkandera sp (Gwangju), and Aspergillus sp (Jeju-do). In the public facilities, the most detected fungi were Cladosporium sp (public transport), Penicillium sp (apartment house, retail market, financial institution, karaoke room), Bjerokandera sp (underground parking lot, public toilet, medical institution), Periconia sp (retail store), and Fusarium sp (general restaurant). Next, we selected twenty airborne fungi to examine their cytotoxicity and proliferation of human skin cells. In this experiment, the proliferation of the cells was influenced by most of the identified fungi. In case of the cytotoxicity test, most genera except for Rhodotorula sp and Moesziomyces sp showed cytotoxicity in HaCaT cells. Conclusions: The distribution of mold in the indoor air in multi-use facilities in South Korea differs from region to region, and this is an indicator that should be considered in future health impact studies. In addition, as a result of culturing about 20 types of bacteria dominant in indoor air, it was found that most (90%) inhibit the growth of skin cells, which can be harmful to health. An in-depth study of the health effects of floating fungi is needed.

A Study on Improving Facial Recognition Performance to Introduce a New Dog Registration Method (새로운 반려견 등록방식 도입을 위한 안면 인식 성능 개선 연구)

  • Lee, Dongsu;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.794-807
    • /
    • 2022
  • Although registration of dogs is mandatory according to the revision of the Animal Protection Act, the registration rate is low due to the inconvenience of the current registration method. In this paper, a performance improvement study was conducted on the dog face recognition technology, which is being reviewed as a new registration method. Through deep learning learning, an embedding vector for facial recognition of a dog was created and a method for identifying each dog individual was experimented. We built a dog image dataset for deep learning learning and experimented with InceptionNet and ResNet-50 as backbone networks. It was learned by the triplet loss method, and the experiments were divided into face verification and face recognition. In the ResNet-50-based model, it was possible to obtain the best facial verification performance of 93.46%, and in the face recognition test, the highest performance of 91.44% was obtained in rank-5, respectively. The experimental methods and results presented in this paper can be used in various fields, such as checking whether a dog is registered or not, and checking an object at a dog access facility.