• Title/Summary/Keyword: test facility

Search Result 1,828, Processing Time 0.024 seconds

Development of a Rotating Turbine Test Rig (회전부를 장착한 터빈 시험장비 개발)

  • Park, Eung-Sik;Song, Seung-Jin;Hong, Yong-Shik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.1 no.1 s.1
    • /
    • pp.58-63
    • /
    • 1998
  • To investigate turbine flow fields under realistic conditions, a rotating turbine test facility has been developed at the Inha University Propulsion Laboratory. The experimental facility consists of an air inlet, settling chamber, single turbine stage test section, and diffuser. This turbine has a design flow coefficient of 0.55 and work coefficient of 1.88. The turbine test rig has four features. First, a large scale test section improves space resolution. Second, low speed rpm enhances safety and reduces required power, Third, DC motor/generator is able to regenerate blower power. Fourth, various types of experiment can be carried out.

  • PDF

A Layout Plan of a Pressure-fed Hot-firing Test Facility for the Performance Evaluation of a Combustion Chamber (연소기 성능평가를 위한 가압식 연소시험설비의 배치 계획)

  • Lee, Kwang-Jin;Cho, Nam-Kyung;Han, Young-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.465-467
    • /
    • 2012
  • A layout plan of a pressure-fed test facility to carry out hot-firing test of liquid rocket engine combustion chamber and purpose of rooms located in the test building were proposed. The layout plan of suggested infrastructure in this paper was determined depending on the design of a vertical test facility to use the natural lay of the land and simulate the initial position of flight model.

  • PDF

DC Arc Characteristics Analysis according to U1699B Test Standardof the Status (태양광발전설비 DC 아크특성 분석)

  • Wan-Su Kim;Kwang-Muk Park
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.118-123
    • /
    • 2023
  • The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

Infrastructure of Propulsion Test Facility of Liquid Rocket (액체로켓 추진기관 시험설비 기반시설 고찰)

  • Cho, Namkyung;Kim, Sunghyuk;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2019
  • Liquid rocket propulsion test facility should provide for the interface condition installed on the upper level system for the test article. In addition, safety provision should be provided to be ready for accident such as explosion which can be occurred during development stage. For this purpose infra-structures of test facilities must be constructed so that stable combustion test can be performed and be guard against accidents. In this article, various aspects for infrastructures of propulsion test facilities are investigated including architecture and civil engineering aspects, test stand, room arrangements, interfaces among facilities, fire-fighting facilities, electrical power facilities.

Construction and Circuital Characteristics of Simple Synthetic Test Facility (간이 합성시험설비의 구성 및 회로특성)

  • Lee, J.H.;Park, K.Y.;Chang, K.C.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.168-170
    • /
    • 1995
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. The analyzed results of the circuit which can be useful for the design stage of the testing facility are also shown. EMTP has been used to analyze the circuit. Two cases of short-circuit test results obtained from the simple synthetic testing facility in KERI are shown with the waveforms of current and voltage. The results also indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

Contribution of thermal-hydraulic validation tests to the standard design approval of SMART

  • Park, Hyun-Sik;Kwon, Tae-Soon;Moon, Sang-Ki;Cho, Seok;Euh, Dong-Jin;Yi, Sung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1537-1546
    • /
    • 2017
  • Many thermal-hydraulic tests have been conducted at the Korea Atomic Energy Research Institute for verification of the SMART (System-integrated Modular Advanced ReacTor) design, the standard design approval of which was issued by the Korean regulatory body. In this paper, the contributions of these tests to the standard design approval of SMART are discussed. First, an integral effect test facility named VISTA-ITL (Experimental Verification by Integral Simulation of Transients and Accidents-Integral Test Loop) has been utilized to assess the TASS/SMR-S (Transient and Set-point Simulation/Small and Medium) safety analysis code and confirm its conservatism, to support standard design approval, and to construct a database for the SMART design optimization. In addition, many separate effect tests have been performed. The reactor internal flow test has been conducted using the SCOP (SMART COre flow distribution and Pressure drop test) facility to evaluate the reactor internal flow and pressure distributions. An ECC (Emergency Core Coolant) performance test has been carried out using the SWAT (SMART ECC Water Asymmetric Two-phase choking test) facility to evaluate the safety injection performance and to validate the thermal-hydraulic model used in the safety analysis code. The Freon CHF (Critical Heat Flux) test has been performed using the FTHEL (Freon Thermal Hydraulic Experimental Loop) facility to construct a database from the $5{\times}5$ rod bundle Freon CHF tests and to evaluate the DNBR (Departure from Nucleate Boiling Ratio) model in the safety analysis and core design codes. These test results were used for standard design approval of SMART to verify its design bases, design tools, and analysis methodology.

Development Test of Alcohol Burner for Turbopump Real-propellant Test Facility (터보펌프 실매질 시험설비를 위한 알코올버너 개발시험)

  • Kim, Jin-Sun;Han, Yeoung-Min;Ko, Youngsung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.79-86
    • /
    • 2014
  • A turbopump real-propellant test facility(TPTF) is to verify the performance of a turbopump unit(TPU) based on liquid oxygen and kerosene. One of the most important sub-facilities is a hot-gas generation system which makes the driving force of the TPU with an alcohol burner. The alcohol burner generates the required flow rates and temperature at the facility using high pressure air and ethanol. In the study, the verification tests of the alcohol burner which was manufactured entirely with domestic technology were performed and fabrication technique and operation skill for the burner could be obtained ahead of the construction of the facility. Two burners will be operated simultaneously for the real-propellant test of 75tf class turbopump and satisfy the power requirement from the turbine of the TPU.

Investigation of transport of radionuclide in a thermal stratification test facility using radiotracer technique

  • Pant, Harish Jagat;Goswami, Sunil;Chafle, Sunil B.;Sharma, Vijay Kumar;Kotak, Vimal;Shukla, Vikram;Mishra, Amitanshu;Gohel, Nilesh C.;Bhattacharya, Sujay
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1449-1455
    • /
    • 2022
  • A radiotracer investigation was carried out in a Thermal Stratification Test Facility (TSTF) with objectives of investigating the dispersion and diffusion of radionuclide and effectiveness of the thermocline to minimize the radionuclide content in the hot water layer. Technetium-99m (99mTc) as sodium pertechnetate was used as a radiotracer in the investigation. Qualitative analysis showed that a thermocline is formed within the TSTF and is effective in preventing the transport of radionuclide from bottom section to the top section of the facility. It was found that the radiotracer injected at the bottom of the pool took about 17.4 h to disperse from bottom to the top of the facility. The results of the investigation helped in understanding the effectiveness of hot water layer and thus to minimize the pool top radiation levels.

Determinant Factors of Service Orientation for Human Resources of Long Term Care Facility (노인장기 요양시설 종사원의 서비스 지향성 결정요인에 관한 연구)

  • Lee, Seong-Duck;Hwang, Yong-Cheol
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.10
    • /
    • pp.39-50
    • /
    • 2018
  • Purpose - This study is to propose discriminative management strategies to long-term care facilities based on the empirical analysis after reviewing the effects of social support, perceived by long-term care facility employees, to service orientation. Research design, data, and Methodology - The research model designed social support, job stress, organizational commitment, and service orientation. The survey collected data from 453 customers in a long-term care facility in jeju. The SPSS 18.0 package was used for analysis. Results - First, social support for long-term care facility employees has a negative(-) effect to job stress. Test results, social support factors except appraisal support had a negative impact on job stress. Second, social support has a positive(+) effect to organizational commitment. Test results, informational support, tangible support and appraisal support had significant effects on organizational commitment. However, emotional support had a positive impact on affective commitment and normative commitment. Third, social support has a positive(+) effect to service orientation. Test results had a positive impact. Fourth, job stress has a negative(-) effect to organizational commitment. In the test results, employee's continuance commitment and normative commitment had significant negative effects in job stress. However, affective commitment had no significant impact. Fifth, job stress has a negative(-) effect to service orientation. Test results showed a negative impact. Conclusions - The study implies the following. First, that there should be a change in the social perception of long-term care facilities. 'Long-Term Care Insurance for The Elderly' was enacted to emphasize this responsibility for the elderly problems as a new system. Enactment of this Act was expected to improve the quality of life of the people by stabilizing the elderly life and reducing the burden of families. Therefore, long-term care facility system should be as efficient as possible for making plans for systematic and organizational support. Second, the efforts of facility managers to minimize job stress of employees is necessary. Accordingly, performing spontaneous work is required for a comfortable working environment and management. Third, the systematic education and training to employees for service oriented behavior of the facility will be required in the long term.

A Study of the Installation Regulation and Condition about a Bicycle Parking Facility of Buildings (건축물의 용도별 자전거주차장 설치기준 및 실태에 관한 연구)

  • Lee, Sung Ok;Kim, Soo Am
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.73-80
    • /
    • 2009
  • The purpose of this paper is to suggest rules and regulations about a bike parking facility, With the objective of expanding bike parking facilities for the comfort of bikers. In Korea, the requirements to establish the facility comply with several regulations like laws for the encouragement of bike usages, rules and regulations for the encouragement of bike usages, regulations of Gyeonggi Regional Corporation rules and Korea National Housing Corporation(Korea Land and Housing Corporation) and requirements for the approval of green buildings. Such rules regulate the number of parking spots depending on the number of nearby houses and the size of a parking facility. Amongst the foreign regulations about the facility is 'obligatory regulations for the establishment of a bike parking facility' in Japan. In the United States, all states apply rules about the bike facility to determine the number of bike parking spots in accordance with the number of car parking spots. Comparing Korean rules regarding the bike parking facility with those of foreign governments will give a good insight into the current situation of Korean regulations. In order to investigate the current usage of bikes, 30 houses in Goyang city, 35 schools, 16 retails shops and 20 medical centers were researched. Thereafter, a correlation test between the size of buildings and the number of bike parking spots was carried out. The result of the test indicates that there is a lack of space for bike parking. It is recommended that the bike parking facility be installed with a convenient access to a building in order to increase the rate of bike usages.