Development of Ultrasonic Test Equipment for Investigating the Morphology of Barrier Materials

  • Kim Sung-Ho;Lee Young-Sam
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.3
    • /
    • pp.217-222
    • /
    • 2006
  • Recently, LG chemical corporation developed new material called HYPERIER, which has an excellent barrier characteristic. It has many layers which are made of nano-composite within LDPE(Low-Density Poly Ethylene). In order to guarantee the quality of the final product from the production line, a certain test equipment is required to investigate the existence of layers inside the HYPERIER. In this work, ultrasonic sensor based test equipment for investigating the existence of inner layers is proposed. However, it is a tedious job for human operators to check the existence by just looking at the resounding waveform from ultrasonic sensor. Therefore, to enhance the performance of the ultrasonic test equipment, wavelet and PCA(Principle Componet Analysis) schemes are introduced into neural network scheme which is used for classification. To verify the feasibility of the proposed scheme, some experiments are executed.

Development and Application of the Super High Temperature Thermal Test Equipment (초고온 열하중 부가장치 개발 및 적용)

  • Jun, Joon-Tak;Kang, Hui-Won;Yang, Myung-Seog
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • This paper describes test result of the Supersonic Wing Structure and the utility of thermal test equipment, which is possible to heat rapidly and continuously above $1,000^{\circ}C$, the durability and reliability of which are improved compared with the existing equipment. Through the test, we could predict the amount of strength reduction of the wing due to aerodynamic heating, caused by exposure of high temperature. Recently the aerodynamic heating temperature of the supersonic flying object is rapidly increased. It is possible to carry out the High Temperature Strength Test on the hypersonic speed flying object with the newly designed thermal test equipment. Because of that, we can upgrade the High Temperature Strength Structure Test technique and test reliability.

RF COMPATIBILITY TEST BETWEEN KOMPSAT AND TTC STATION

  • Ahn, Sang-Il;Choi, Hae-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.191-198
    • /
    • 1999
  • Results of RF compatibility test between KOMPSAT(Korea Multi-Purpose SATellite) and TTC(Tracking, Telemetry, and Command) station are described. S/C(Spacecreft) RF Test, telemetry test, command test, ranging test, and tracking receiver test were performed with respect to pass/fail criteria. To provide physical RF interface between KOMPSAT and TTC equipment, direct low cable and antenna-to-antenna interface were implemented. Through RF compatibility test, it was fully demonstrated that KOMPSAT and TTC equipment are functionally workable.

  • PDF

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

The Performance Analysis to Identify the Reuse and Assembly Impact of Temporary Equipment

  • Bae, Sung-Jae;Park, Jun-Beom;Kim, Jung-Yeol;Kim, Young-Suk;Kim, Jun-Sang;Jo, Jae-Hun
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1252-1252
    • /
    • 2022
  • Temporary work that utilizes temporary equipment (e.g., system scaffold and system pipe support) in construction work is one of the most vulnerable work from a safety perspective in South Korea. Typically, temporary equipment is reused at construction sites. The Korea Occupational Safety and Health Agency announced guidelines regarding the performance standards for reusable temporary equipment to prevent the accidental collapse of temporary facilities. Nevertheless, temporary facilities' collapse still occurs, which could be attributed to a degradation in the performance due to the reuse of temporary equipment. Therefore, this study investigated the performance of simple temporary structures assembled with new and reused equipment. To this end, an experimental module was designed based on previous research cases, and two experimental models were constructed, in which one was assembled using new equipment (Model A), and the other was built using reused equipment (Model B). To determine the performance of each model, a load test was conducted to measure the maximum load that each model could withstand. The experimental results revealed that the maximum load of Model B was 15% lower than that of Model A. This indicates that there is a meaningful performance difference between those two models. Based on this result, the authors decided to perform additional tests with more realistic models than previous ones. The new experimental module was designed to ensure compliance with the Korean design guidelines. In this presentation, the authors show details of the first tests and their results and plan for the additional test.

  • PDF

A Study on the Development of Inhalation Equipment for Seabed Sediment by the Difference of Water Head (수두차를 이용한 해저퇴적물 흡입장비 개발에 관한 연구)

  • Lee, Young-Gill;Son, Choong-Yul;Jeong, Uh-Cheul;Kim, Kang-Sin;Jeong, Kwang-Leol
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.261-264
    • /
    • 2006
  • This paper deal with development of dredging equipment that proper water head elimination method changing transitional dredging method. Numerical simulation and model test were accomplished for development of seabed sediment inhalation equipment using water head. Sediment elimination system by the difference of water head has been analysed by numerical method. Model test was achieved for inhalation equipment performance test using water head by primary design. Also sediment elimination system has designed and developed that doesn't occur secondary pollution phenomenon. To verify the numerical results are compared with experimental results.

  • PDF

Flip Chip Bump 3D Inspection Equipment using White Light Interferometer with Large F.O.V. (대시야 백색광 간섭계를 이용한 Flip Chip Bump 3차원 검사 장치)

  • Koo, Young Mo;Lee, Kyu Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.4
    • /
    • pp.286-291
    • /
    • 2013
  • In this paper, in-line type flip chip bump 3D inspection equipment, using white light interferometer with large F.O.V., which is aimed to be used in flip chip bump test process is developed. Results of flip chip bump height measurement in many substrates and repeatability test results for the bumps in fixed location of each substrate are shown. Test results from test bench and those from developed flip chip bump 3D inspection equipment are compared and as a result repeatability is improved by reducing the impact of system vibration. A valuation basis for the testing quality of flip chip bump 3D inspection equipment is proposed.

Development of a Workload Index for Monitoring Durability Test of an Excavator (굴착기 내구시험 모니터링을 위한 작업부하 지표 개발)

  • Cho, Jae-Hong;Na, Seon-Jun;Kim, Min-Seok;Park, Myeong-Kwan
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.29-35
    • /
    • 2022
  • In this paper, we developed a workload index for monitoring the durability test using operation information of an excavator. First, the acceleration and cylinder pressure were selected as load factors by analyzing operation data. Through load correlation analysis according to each load factor, Root Mean Square (RMS) and Work Load Range (WLR) were respectively derived as a load feature representing mechanical load. In addition, the workload index was used to quantify load features. For applying the workload index to monitoring, a real-time monitoring system consisting of sensors and embedded controller was installed on the excavator and the system was integrated with a remote monitoring environment using a wireless network. Results of load monitoring and analysis verified that the developed workload index was effective from the viewpoint of the relative comparison of the workload.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine (이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석)

  • Bae, Jongsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.