• Title/Summary/Keyword: test duration

Search Result 2,074, Processing Time 0.031 seconds

Effects of Loading Conditions on Consolidation Beharion of the Soft Clay (하중조건이 연약초토의 압밀에 미치는 영향)

  • 강병희
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.4
    • /
    • pp.2445-2455
    • /
    • 1971
  • One-dimensional Consolidation tests with pore pressure measurement were caried in the ANTE-US consolidometer in order to investigate the effects of loading conditions on consolidation behavior of the soft clay. Undisturbed specimens of a sensitive clay were loaded in load-increment ratioes 0.5, 1.0 and 2.0, and load increment duration of 1, 6, 12, 24 and 48 hours with the application of 40 psi of back pressure. There is no significant effect of load-increment ratio on compression-pressure relationship, but the test with one-hour load increment duration doesn't represent the same results of the standard consolidation test in the sensitive clay.

  • PDF

Experimental Study on Mixing Stability and Macroscopic Spray Characteristics of Diesel-gasoline Blended Fuels (디젤-가솔린 혼합연료의 혼합안정성 및 거시적인 분무 특성에 관한 실험적 연구)

  • Park, Sewon;Park, Su Han;Park, Sungwook;Chon, Mun Soo;Lee, Chang Sik
    • Journal of ILASS-Korea
    • /
    • v.17 no.3
    • /
    • pp.121-127
    • /
    • 2012
  • The study is to investigate the mixing stability, fuel properties, and macroscopic spray characteristics of diesel-gasoline blended fuels in a common-rail injection system of a diesel engine. The test fuels were mixed diesel with gasoline fuel, which were based volume fraction of gasoline from 0 to 100% in 20% intervals. In order to analyze the blended effect of gasoline to diesel fuel, the properties of test fuels such as density, viscosity, and surface tension were measured. In addition, the spray behavior characteristics were studied by investigating the spray tip penetration and spray angle using a spray images through a spray visualization system. It was revealed that the density, kinematic viscosity and surface tension of diesel-gasoline blending fuels were decreased with the increase of gasoline fuel. The injection quantity of test fuels were almost similar level at short energizing duration condition. On the other hand, the increase of energizing duration shows the decrease of injection quantity compared to short energizing duration. The test blending fuels have similar growth in Spray tip penetration and Spray cone angle.

Analysis of Effect by Duration of Cryotherapy in the Posterior region of Neck for College Students

  • Ji Hong Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.301-306
    • /
    • 2023
  • Attention is a fundamental aspect in the cognitive process of human. Cognitive system of human body requires to focus on selected information among a vast amount of information from sensory organs. It has widely studied that various environmental factors affected the level of attention; however, few researches have aimed to the effect of direct cryotherapy. In this research, level of attention was studied comparing sub-indexes of FAIR test between groups with different duration of direct cryotheapy to the back of neck. FAIR test is a evaluation tool for visual attention consisting of three sub-indexes. Selective attention, accuracy of attention, and persistence of attention can be independently analyzed by FAIR test. In the analysis of selective attention, cryotherapy for 5 to 20 minutes showed higher result than cryotherapy for 40 minutes. In the analysis of persistence of attention, cryotherapy for 5 to 15 minutes showed higher result than cryotherapy for 40 minutes. Overall, selective attention and persistence of attention turns out to be maximized between 5 to 20 minutes of cryotherapy and tends to decrease afterwards. However, accuracy of attention does not seem to be affected by the duration of cryotherapy. Correlation between selective attention and the skin temperature by cryotherapy tends to be negative supporting the findings by ANOVA and post-hoc test. Correlation between persistence of attention and the skin temperature showed similar results.

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

The Optimization for Type "C" LLRT Requirements of Containment Vessel (격납용기 Type "C" 누설률시험 요건 최적화)

  • Jung, Nam-Du;Kim, Jae-Dong;Kim, In Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS-56.8(1994) in Korea. Two methods, the make-up flow rate and the pressure decay, are used for LLRT. Though ANSI/ANS-56.8 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the test period for type "C" LLRT is differently applied to each NPPs. Therefore, this study presents a unified test criteria for data stabilization and test duration through experiments to improve the test reliability for type "C".

  • PDF

A Tracking Test for PE Series Insulations (PE 계열 절연재의 내트래킹 성능 평가)

  • Jung, Jong-Wook;Jung, Jin-Soo;Yi, Geon-Ho;Park, Ha-Yong;Kim, Nam-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.154-155
    • /
    • 2006
  • This paper describes a tracking test results for the organic polymers with PE(polyethylene) series by a declining method. After processing the 4 PE series insulations with different density, the tracking duration for each was measured and compared with that for ABS(acrylonitrile butadiene styrene). The surface condition of each specimen was carefully observed after the tracking test. As a result, HDPE showed excellent performance in tracking test.

  • PDF

Statistical Design of Two-Stage Reliability Demonstration Tests (2단계 신뢰성 실증시험의 통계적 설계)

  • Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.2
    • /
    • pp.313-319
    • /
    • 2011
  • In design verification and process validation stages, reliability demonstration tests(RDT's) are common practice in industry, A new two-stage RDT that is known to be more efficient than a corresponding single-stage one in terms of expected test duration for Weibull distribution is proposed. Zero or one failure two-stage plans to minimize expected test duration under Type I and hybrid censoring subject to satisfying consumer's risk at a specified reliability target are developed and a numerical example is provided to illustrate the proposed two-stage RDT plans and compared with other one- and two-stage plans.

Relationship Between Pendulum Test Measurements of Post-Stroke Spasticity (뇌졸중 후 강직 평가를 위한 진자검사 측정값의 상관관계)

  • Kim, Yong-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.325-332
    • /
    • 2010
  • The purpose of this study was to investigate the relationship between three quantitative measures of the pendulum test for spasticity in strokes: The relaxation index, the number of oscillations, and the duration of oscillations. Twenty-six stroke subjects participated in the study. Correlations among these measures of spasticity used Pearson's correlation coefficient. There was a statistically significant positive correlation between the relaxation index and number of oscillations in strokes (r=.881, p<.01). In addition there was significant positive correlation between the relaxation index and duration of oscillations (r=.896, p<.01), and between the number of oscillations and duration of oscillations (r=.938, p<.01). Thus, it is possible to use the number of oscillations and duration of oscillations as quantitative measures of spasticity, rather than the relaxation index, which is more complicated to obtain. According to the result of this study, the use of the simple and objective measurements of the number of oscillations and the duration of oscillations are required clinically in the quantitative measures of spasticity in the future.

Development and sustained release effect of implantable formula of somatotropin (Somatotropin 이식 제형 개발과 지속적 방출 효과)

  • Kim, Nam-Joong
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • The present study was carried out to develop a sustained release implantable formula of bovine somatotropin (SRIF-BST) and to examine its sustained release effect. The SRIF-BST was produced by coating a solid pellet, which was comprised of BST and an excipient, made of a biodegradable polymer and poloxamer, which are capable of regulating the rate of BST release. The coated membrane of SRIFBST was observed with a field emission scanning electron microscope. The thickness of the coated membrane was approximately $1{\mu}m$, and the pore sizes of the coated membrane surface were below $10{\mu}m$. In dissolution test, the release duration of the SRIF-BST maintained for 10 days, whereas the release duration of the control BST formula maintained for 3 days. In weight gain assay and tibia test of hypophysectomized rats, the release duration of the SRIF-BST treated group was 12 days and the net weight gain was 53.16 g, also the tibia length and strength of the SRIF-BST treated group was increased 10.5% and 23.1% compared with those of the control group, respectively.

Sleep Patterns and Early Adjustment in 1- to 3-year-old Children in Daycare (영유아의 수면양상과 어린이집 초기 적응)

  • Kim, Jinwook
    • Journal of Families and Better Life
    • /
    • v.32 no.2
    • /
    • pp.41-52
    • /
    • 2014
  • The present study investigated the sleep patterns 1-to 3-year-old children and examined whether their sleep patterns would predict their early adjustment to daycare centers. The participants were 239 young children attending daycare centers in Seoul. The data on children's sleep patterns were collected by parent report. Children's adjustment to daycare was assessed by daycare providers' reports. The data were analyzed by means of Chi-square test, t-test, Pearson's correlation, ANOVA and discriminant analysis. The results were as follows: Children from dual-earner families had shorter nocturnal sleep duration than those from single-earner families. There was no significant relation between daytime sleep duration and sleep-onset time at night. It was found that children who go to bed earlier were more likely to get sufficient sleep without nocturnal wakefulness. Age and total sleep duration were seen to be significant variables when it came to discriminating between the adjustment versus maladjustment groups.