A study on the current limiting characteristics and magnetic analysis of the non-inductively wound coil (타입에 따른 무유도 권선형 코일의 한류 특성연구 및 자장해석)

  • Jang, Jae-Young;Park, Dong-Keun;Chang, Ki-Sung;Na, Jin-Bae;Kim, Won-Cheol;Chung, Yood-Do;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • To reduce the power loss in normal state, non-inductively wound high temperature superconducting (HTS) coils are used for fault current limiter (FCL) application. Non-inductively wound coils can be classified into two types: solenoid type and pancake type. These two types have different electrical and thermal and mechanical characteristics due to their winding structure difference. This paper deals with the current limiting characteristics, magnetic field analysis of the two coils. Simulation using finite element method (FEM) was used to analyze the magnetic field distribution and inductance of the coils. Short circuit test using stabilizer-free coated conductor (CC) was also carried out. We can compare the characteristics of the two types of coil by using the data obtained from simulation and short circuit test. We confirmed the feasibility of FCL application by the analysis about the characteristics of non-inductively wound coil using CC.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

Reheating Process of Particulates Reinforced Metal Matrix Composites for Thixoforming (Thixoforming을 위한 입자강화형 금속복합재료의 Reheating 공정)

  • 이동건;안성수;강충길
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.218-223
    • /
    • 2000
  • A both mixing process of electro-magnetic stirring and mechanical process technique were used to fabricate particulate metal matrix composites(PMMCs) for variation of particle size. The PMMCs were tested for their tensile test for with and without heat treatment with T6. PMMCs fabrication processing conditions for both electrical and mechanical process are also suggested. In order to thixoforming of PMMCs, fabricated billet are reheated by using the optimal coil designed as a function of length between PMMC billet and coil surface, coil diameter and billet length. The effect of reinforcement distribution on billet temperature variation are investigated with calculated solid fraction theory proposed as a function of matrix alloy and volume fraction of reinforcement.

  • PDF

Evaluation of Heat Transfer performance of Wire-coil Inserted Tube (와이어코일 삽입법을 이용한 열전달 촉진기술 성능평가)

  • 이주동;박종호;이상천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.457-465
    • /
    • 2000
  • An experiment was carried out to evaluate the thermal performance of the wire-coil inserts method. Tested were the smooth tubes with the wire-nil inserts of various pitch and helix angle combinations. Test fluids were the 50%-solution of the ethylene glycol and the Hue water. Heat transfer coefficient and friction factors were deduced from the measured values of temperatures, flowrates and pressure drops. A unified dimensionless correlation for the heat transfer coefficients was developed as a function of the pitch to diameter ratio, the Reynolds number and the Prandtl number. An exergy analysis was performed to evaluate an optimal operating condition with the wire-coil inserts.

  • PDF

A Study on the Development of the Side Load Coil Spring (횡력발생 코일스프링 설계 및 제조에 관한 연구)

  • Kwon, H. H.;Choi, S. J.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.5
    • /
    • pp.98-105
    • /
    • 1998
  • In the automotive suspension system, especially, Mcpherson strut type, if the resultant of the force through tire and the link reaction force is not coincident with the spring force, the side load against shock-absorber occur. The magnitude of side load is proportional to the difference between resultant force and spring force. To reduce side load, several method can be used, and one is to use the side load coil spring. This study summarize the development results of side load coil spring, i.e., how to design, analysis, manufacture, and test.

  • PDF

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Gastric Phantom (팬텀을 이용한 다기능 위$\cdot$십이지전관 코일 카테타의 유용성 평가)

  • Lim Jin-Oh;Kim Tae-Hyung;Jung Yang-Hwa;Choi Won-Chan;Lee Kwang-Jong;Song In-Wook;Lee hyeong-Jin
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.29 no.1
    • /
    • pp.61-66
    • /
    • 2003
  • Purpose : To evaluate was the newly designed gastroduodenal coil catheter: in-vitro test. Material and Method : the coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3m inner diameter and

  • PDF

REBCO coil operation in gaseous helium and solid nitrogen

  • Diev, D.N.;Makarenko, M.N.;Naumov, A.V.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.3
    • /
    • pp.47-50
    • /
    • 2019
  • The paper gives the results of the experiments with a model two-section REBCO solenoid cooled by either gaseous helium (GHe) or sub-cooled/solid nitrogen (SN2) in (50-77) K temperature range. The major cooling source was a single-stage cryocooler Sumitomo CH-110 with the cooling power of 175 W and 130 W at 77 K and 50 K respectively. The coil itself was not directly conduction cooled. We compare the time taken by both coolants to obtain the temperature of the magnet of about 50 K and the homogeneity of the temperature distribution within the cryostat. Test results for the coil operation in solid nitrogen together with the comparison of its critical properties in SN2 and GHe are also presented.

Quantitative vibratory sense measurement systems of a diabetic neuropathy (당뇨병성 신경병증의 정량적 진동 감각 측정 시스템)

  • Ryu, Bong-Jo;Kim, Youngshik;Koo, Kyung-Wan
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.615-620
    • /
    • 2018
  • Evaluation of clinical usefulness of current perception threshold test and vibration sense perception threshold test in diagnosing the diabetic poly-neuropathy patients is one of the diagnosis methods for diabetic poly-neuropathy. Up to the present, some diagnostic methods were used for diabetic poly neuropathy patients. For example, there are neuropathy impairment score test of lower limbs, nerve conduction test, cooling detection threshold test, heat-pain threshold test and so on. However, most of the above tests require very expensive cost and take a lot of time in test. In this paper, a new apparatus estimating vibration sense ability is introduced. For this purpose, the VCM(voice coil motor) stimulating patient's peripheral nerve and current amplifier were manufactured. Also, softwares sensing and driving the vibration detection threshold test in order to measure the quantitative vibration sensory levels in diabetic poly-neuropathy patients were developed.

Design of a Moving-magnet Electromagnetic Actuator for Fast Steering Mirror through Finite Element Simulation Method

  • Long, Yongjun;Mo, Jinqiu;Wei, Xiaohui;Wang, Chunlei;Wang, Shigang
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.300-308
    • /
    • 2014
  • This paper develops a moving-magnet electromagnetic actuator for fast steering mirror (FSM). The actuator achieves a reasonable compromise between voice coil actuator and piezoelectric actuator. The stroke of the actuator is between the strokes of a piezoelectric actuator and a voice coil actuator, and its force output is a linear function of air gap and excitation current within our FSM travel range. Additionally, the actuator is more reliable than voice coil actuator as the electrical connection in the actuator is static. Analytically modeling the actuator is difficult and time-consuming. Alternatively, numerous finite element simulations are carried out for the actuator analysis and design. According to the design results, a real prototype of the actuator is fabricated. An experimental test system is then built. Using the test system, the force output of the fabricated actuator is evaluated. The test results validate the actuator analysis and design.

Design, fabrication and test of inside notched superconducting coil (내노치형 초전도 솔레노이드 마그네트의 설계.제작 및 평가)

  • Nah, Wan-Soo;Jin, Hong-Beom;Oh, Bong-Hwan;Kwon, Young-Kil;Oh, Sang-Soo;Cho, Jeon-Wook;Ha, Dong-Woo;Lee, Eon-Yong;Ryu, Kang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.63-65
    • /
    • 1994
  • In this paper, the design, fabrication and test of inside notched superconducting coil are described. The inside notched coil is one of the basic configurations, producing homogeneous magnetic field. This magnet is a primitive version of MRI or NMR magnet in Korea Electromagnetic Research Institute. To test the magnetic field distribution inside the magnet, a X-Z scanner was made and the homogeneity was about $1.8{\times}10^{-3}$in 5 cm dsv (Diameter of Spherical Volume).

  • PDF