• 제목/요약/키워드: tension reinforcement

검색결과 333건 처리시간 0.024초

철근의 Bending and Straightening에 대한 실험적 연구 (An Experimental Study on the Cold Bending of Reinforcing Bar)

  • 조현우;최희복;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.109-113
    • /
    • 2003
  • In this experiment, we distribute the bending angle to 60$^{\circ}$, 90$^{\circ}$, 120$^{\circ}$, and we separate it in to two groups. One is straightening right after bending and the other is straightening after one week. The bars we will use are HD13 and HD16. The number of tests will be 60 times. In the case of HD16, the increase of bending angle decreased yield strength and maximum strength. And compared with thinner bars, HD16 showed bigger differences in yield strength and maximum strength when the 'being bent' duration got longer. So it shows that when we bend and after straighten a bar, stress change takes place on the surface of the bar. At the beginning it shows it's ductility after that it deforms while transforming it's character to destroying. And also, if we straighten a bar after bending, it doesn't get straighten like the original form. So it makes torsion and this torsion makes moments in different areas.

  • PDF

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.

Flexural behavior of reinforced concrete beams strengthened with a hybrid inorganic matrix - steel fiber retrofit system

  • Papakonstantinou, Christos G.;Katakalos, Konstantinos
    • Structural Engineering and Mechanics
    • /
    • 제31권5호
    • /
    • pp.567-585
    • /
    • 2009
  • The aim of this study was to investigate the flexural behavior of reinforced concrete beams strengthened with a novel strengthening system. Concrete beams were strengthened with a hybrid retrofit system consisting of high strength steel cords impregnated in an inorganic fireproof matrix (Geopolymer). The strengthened reinforced concrete beams along with non-strengthened control beams were tested monotonically under four point bending loading conditions. Moreover, an analytical model is introduced, that can be used to analyze the flexural performance of the strengthened beams. The experimental results indicate that the failure of the strengthened beams was based on the yielding of the reinforcement in the tension face of the beams, followed by a local slippage of the steel cords. The flexural stiffness of the strengthened beams was significantly improved compared to the stiffness of the non-strengthened beams. In conclusion, the strengthening system can provide an effective alternative to commercially available systems.

하이브리드 섬유를 사용한 고인성 섬유보강 시멘트 복합체내의 철근이음에 관한 실험적 연구 (An Experimental Study on the Splice of Reinforcement Embedded in High Performance Hybrid Fiber Reinforced Cementitious Composites)

  • 전에스더;양일승;한병찬;서수연;윤승조;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.319-322
    • /
    • 2005
  • Experimental results on splice strength of concrete and hybrid fiber reinforced cementitious composite are reported. Two series of tests, with six specimens each, were carried out. The research parameters were: bar diameter(D16, D22), lap splice length(50, 75, 100$\%$). The current experimental results demonstrated clearly that the use of hybrid fibers in cementitious matrixes increases significantly the splice strength of reinforcing bars in tension. Also, the presence of fibers increased the number of cracks formed around the spliced bars, delayed the growth of the splitting cracks, and consequently, improved the ductility of bond failure.

  • PDF

Balanced Ratio of Concrete Beams Internally Prestressed with Unbonded CFRP Tendons

  • Lee, C.;Shin, S.;Lee, H.
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.1-16
    • /
    • 2017
  • The compression or tension-controlled failure mode of concrete beams prestressed with unbonded FRP tendons is governed by the relative amount of prestressing tendon to the balanced one. Explicit assessment to determine the balanced reinforcement ratio of a beam with unbonded tendons (${\rho}^U_{pfb}$) is difficult because it requires a priori knowledge of the deformed beam geometry in order to evaluate the unbonded tendon strain. In this study, a theoretical evaluation of ${\rho}^U_{pfb}$ is presented based on a concept of three equivalent rectangular curvature blocks for simply supported concrete beams internally prestressed with unbonded carbon-fiber-reinforced polymer (CFRP) tendons. The equivalent curvature blocks were iteratively refined to closely simulate beam rotations at the supports, mid-span beam deflection, and member-dependent strain of the unbonded tendon at the ultimate state. The model was verified by comparing its predictions with the test results. Parametric studies were performed to examine the effects of various parameters on ${\rho}^U_{pfb}$.

Mechanical properties of natural fiber-reinforced normal strength and high-fluidity concretes

  • Kim, Joo-Seok;Lee, Hyoung-Ju;Choi, Yeol
    • Computers and Concrete
    • /
    • 제11권6호
    • /
    • pp.531-539
    • /
    • 2013
  • An experimental investigation of mechanical properties of jute fiber-reinforced concrete (JFRC) has been reported for making a suitable construction material in terms of fiber reinforcement. Two jute fiber reinforced concretes, called jute fiber reinforced normal strength concrete (JFRNSC) and jute fiber-reinforced high-fluidity concrete (JFRHFC), were tested in compression, flexure and splitting tension. Compressive, flexural and splitting tensile strengths of specimens were investigated to four levels of jute fiber contents by volume fraction. From the test results, Jute fiber can be successfully used for normal strength concrete (NSC) and high-fluidity concrete (HFC). Particularly, HFC with jute fibers shows relatively higher improvement of strength property than that of normal strength concrete.

Upgrading flexural performance of prefabricated sandwich panels under vertical loading

  • Kabir, M.Z.;Rezaifar, O.;Rahbar, M.R.
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.277-295
    • /
    • 2007
  • 3-D wall panels are used in construction of exterior and interior bearing and non-load bearing walls and floors of building of all types of construction. Fast construction, thermal insulation, reduced labor expense and weight saving are the most well pronounced advantage of such precast system. When the structural performance is concerned, the main disadvantage of 3D panel, when used as floor slab, is their brittleness in flexure. The current study focuses on upgrading ductility and load carrying capacity of 3D slabs in two different ways; using additional tension reinforcement, and inserting a longitudinal concentrated beam. The research is carried on both experimentally and numerically. The structural performance in terms of load carrying capacity and flexural ductility are discussed in details. The obtained results could give better understanding and design consideration of such prefabricated system.

Analytical evaluation of the moment-rotation response of beam-to-column composite joints under static loading

  • da Silva, L. Simoes;Coelho, Ana M. Girao;Simoes, Rui A.D.
    • Steel and Composite Structures
    • /
    • 제1권2호
    • /
    • pp.245-268
    • /
    • 2001
  • The analysis of steel-concrete composite joints presents some particular aspects that increase their complexity when compared to bare steel joints. In particular, the influence of slab reinforcement and column concrete encasement clearly change the moment-rotation response of the joint. Starting from an energy approach developed in the context of steel joints, an extension to composite joints is presented in this paper that is able to provide closed-form analytical solutions. In addition, the possibility of tri-linear or non-linear component behaviour is also incorporated in the model, enabling adequate treatment of the influence of cracked concrete in tension and the softening response of the column web in compression. This methodology is validated through comparison with experimental tests carried out at the University of Coimbra.

Flexural Behavior of RC Beams Strengthened with Steel Plates/Carbon Fiber Sheets(CFS) under Pre-Loading Conditions

  • Shin, Yeong-Soo;Hong, Geon-Ho
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.69-77
    • /
    • 2000
  • The reinforced concrete(RC) flexural members strengthened with steel plate/CFS at soffit have initial stresses and strains in reinforcements and concrete caused by the service loads at the time of retrofitting works. These initial residual stresses and strains of strengthened beams may affect the flexural performance of the rehabilitated beams. The objective of this study is to evaluate and verify the effectiveness of rehabilitation by external bonded steel plates and CFS to the tension face of the beams under three conditions of pre-loading. Thirteen beam specimens are tested and analyzed. Main test parameters are pre-loading conditions, strengthening materials and reinforcement ratio of specimens. The effect of test parameters on the strengthened beams is analyzed from the maximum load capacity, load-deflection relationship, state of stress of the materials. crack propagation phase, and failure modes. Both test results and design formulas of ACI Code provisions are compared and evaluated.

  • PDF

PVA 혼입률에 따른 HPFRCC의 역학적 특성에 관한 실험적 연구 (Experimental Study on the Mechanical Properties of HPFRCC with Fiber Volume Fraction of PVA Fiber)

  • 변장배;이원석;전에스더;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.653-656
    • /
    • 2006
  • High performance fiber-reinforced cementitious composite(HPFRCC) encompass a wide variety of cementitious composites whose behavior in tension is significantly more ductile than that of traditional fiber-reinforced concrete. Fibers in HPFRCC are increasingly being used for the reinforcement of cementitious matrix to enhance the toughness and energy absorption capacity and to reduce the cracking sensitivity of the matrix. In the past decade, HPFRCC have evolved with intensified research. HPFRCC for structural applications has been developed under the performance driven design approach. It is the aim of this study to obtain development of HPFRCC using polyvinyl-alcohol fiber(PVA). It was targeted a requirement of economic mixing and apply to structure member.

  • PDF