• 제목/요약/키워드: tensile tester

검색결과 168건 처리시간 0.024초

Overlay Tester를 이용한 그리드 보강 아스팔트 포장의 반사균열 저항성 평가 (Evaluation of Reflection Cracking Resistance of Grid-Reinforced Asphalt Pavement Using Overlay Tester)

  • 유병수;서우진;김조순;박대욱
    • 한국도로학회논문집
    • /
    • 제18권1호
    • /
    • pp.57-62
    • /
    • 2016
  • PURPOSES : Reflection cracking has been one of the major causes of distress when asphalt pavement is laid on top of concrete pavement. This study evaluated the reflection cracking resistance of asphalt mixtures reinforced with asphalt embedded glass fiber and carbon fiber using a Texas Transportation Institute (TTI) overlay tester. METHODS : Different asphalt mixtures such as polymer-modified mastic asphalt (PSMA) and a dense graded asphalt mixture were reinforced with asphalt-embedded carbon fiber and glass fiber. For comparison purposes, two PSMA asphalt mixtures and one dense graded asphalt mixture were evaluated without fiber reinforcement. Two different overlay test modes, the repeated overlay test (R-OT) and monotonic overlay test (M-OT), were used to evaluate the reflection cracking resistance of asphalt mixtures at $0^{\circ}C$. In the R-OT test, the number of repeated load when the specimen failed was obtained. In the M-OT test, the tensile strength at the peak load and tensile strain were obtained. RESULTS : As expected, the fiber-reinforced asphalt mixture showed a higher reflection cracking resistance than the conventional nonreinforced asphalt mixtures based on the R-OT test and M-OT test. The dense graded asphalt mixture showed the least reflection cracking resistance and less resistance than the PSMA. CONCLUSIONS : The TTI overlay tester could be used to differentiate the reflection cracking resistance values of asphalt mixtures. Based on the R-OT and M-OT results, the carbon-fiber-reinforced asphalt mixture showed the highest reflection cracking resistance among the nonreinforced asphalt mixtures and glass-fiber-reinforced asphalt mixture.

인발가공된 스테인리스강선의 표면특성에 미치는 Ni코팅의 영향 (Effects of Ni Coating on the Surface Characteristics of Drawed Stainless Steel Wire)

  • 최한철
    • 한국표면공학회지
    • /
    • 제36권5호
    • /
    • pp.398-405
    • /
    • 2003
  • The stainless steel wire requires good corrosion resistance and mechanical properties, such as drawing ability, combined with a high resistance to corrosion. For increasing drawing ability of stainless steel, Ni coating methods have been used in this study. However, there is no information on the electrochemical corrosion behavior of drawed wires after Ni coating. To investigate corrosion resistance and mechanical property of drawed wire, the characteristics of Ni coated wires have been determined by tensile strength tester, hardness tester, field emission scanning microscope, energy dispersive x-ray analysis and potentiodynamic method in 0.1 M HCl. The drawed stainless steel wires showed the strain-induced martensitic structure, whereas non-drawed stainless steel wire showed annealing twin in the matrix of austenitic structure. The hardness and tensile strength of drawed stainless steel wire were higer than that of non-drawed stainless steel wire. Electrochemical measurements showed that, in the case of drawed stainless steel o ire after Ni coating, the corrosion resistance and pitting potential increased compared with non-coated and drawed stainless steel wire due to decrease in the surface roughness.

Poly(methyl acrylate)-Poly(acrylonitrile) 공중합체의 응력완화 (Stress Relaxation of Poly(methyl acrylate)-Poly(acrylonitrile) Copolymers)

  • 김남정
    • Elastomers and Composites
    • /
    • 제47권3호
    • /
    • pp.223-230
    • /
    • 2012
  • 응력완화 실험 곡선을 Eyring-Halsey 비뉴톤 모델의 이론식에 적용하여 poly(methyl acrylate)-poly(acrylonitrile) 공중합체의 유변학적 파라메타를 얻었다. 응력완화 실험은 용매기를 부착한 인장 시험기를 사용하였다. 유동 파라메타를 컴퓨터 프로그램을 이용하여 계산하였다. 이들 시료의 유동 파라메타는 유동 단위의 자체확산, 유동점성, 유동 활성화 에너지와 직접적인 연관을 갖는 것으로 규명되었다.

박막의 기계적 물성을 위한 새로운 인장 시편 및 인장 시험기 (A Novel Tensile Specimen and Tensile Tester for Mechanical Properties of Thin Films)

  • 박준협;김윤재
    • 대한기계학회논문집A
    • /
    • 제31권6호
    • /
    • pp.644-650
    • /
    • 2007
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of thin film used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed a tensile testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, it is described that new techniques and procedures can be adopted for high cycle fatigue test of a thin film.

Goldish Yellow Color인 수종(數種)의 치과용(齒科用) 비귀금속합금(非貴金屬合金) 경도(硬度), 강도(强度) 및 미세조직(微細組織)의 비교(比較)에 관(關)한 연구(硏究) (A Study on the Comparison of hardness, Strength and Microstructure of dental Non-precious Metal Alloys Colored Goldish Yeller)

  • 김재도
    • 대한치과기공학회지
    • /
    • 제14권1호
    • /
    • pp.55-65
    • /
    • 1992
  • The purpose of this study was to investigate the comparison of physical properties of nonprecious metal alloys colored goldish yellow. The experimental groups were copper based dental alloy and control group was Ni-Cr based dental alloy used crown and bridges frameworks. Hardness was tested by vickers hardness tester, tensile strength was tested by universal tension tester. After testing the tensile strength of castings, the microstrucure and the pattern of fracture were investigated by scanning electron microscope and metallurgical microscope. The results were as follows : Hardness of Ni based alloy was higher than Cu based alloys. Hardness number of A group was 200.41$\pm$16.10 Hv, B group was 194.33$\pm$1.69 Hv, C group was 139.29$\pm$2.19 Hv and D group was 293.81$\pm$27.17 Hv, respectively. Tensile strength of D group was 56.42$\pm$6.17 $kg/m^2$, A group was 50.39$\pm$5.68 $kg/m^2$, C group was 45.13$\pm$4.53 $kg/m^2$, B group was 45.25$\pm$9.25 $kg/m^2$, in order, and D group was maximum tensile strength. The fractured surfaces of tensile specimens in the all groups showed the tendency to form large voids in the center of specimens. Thus the ductile fracture was changed into the brittle fracture with the fine grain size.

  • PDF

탄소섬유/에폭시 복합재 링 시편의 노화 특성 평가 (Aging Characteristics of Carbon Fiber/Epoxy Composite Ring Specimen)

  • 윤성호;오진오
    • Composites Research
    • /
    • 제22권6호
    • /
    • pp.39-44
    • /
    • 2009
  • 가속노화장치를 이용하여 노출시간에 따른 탄소섬유/에폭시 복합재 링 시편의 노화 특성을 평가하였다. 온도, 수분, 자외선 등의 복합적인 노출조건은 최대 3000시간까지 적용하였다. 노출시간에 따른 링 시편의 인장특성과 곡률의 영향이 고려된 굽힘특성은 하중시험장치를 이용하여 평가하였으며 노화표면은 전자현미경을 통해 관찰하였다. 연구결과에 따르면 인장강성은 환경인자의 노출시간에 큰 영향을 받지 않지만 인장강도는 노출 초기에 물리시효 현상과 경화 반응으로 다소 증가하지만 노출시간이 길어지면 열화 영향으로 감소하였다. 굽힘탄성계수와 굽힘강도는 노출초기에 다소 증가하지만 노출시간이 길어지면 감소하는 양상을 나타내었다. 또한 전자현미경을 통해 관찰된 노화표면은 환경인자의 노출시간에 따라 달라지기 때문에 환경인자의 노출시간에 따른 기계적 특성의 변화를 규명하기 위한 정보를 제공해 준다.

빛의 강도에 따른 광경화성 하이드로겔 섬유의 기계적 물성 (Mechanical Property of Photocurable Hydrogel Fiber by Light Intensity)

  • 이상민;추보경
    • 한국기계가공학회지
    • /
    • 제20권10호
    • /
    • pp.38-43
    • /
    • 2021
  • Photocurable hydrogels are widely used as 3D printing materials in tissue engineering (e.g., scaffold fabrication) as well as optical fibers (or optical sensors) materials. Photocurable hydrogels can control optical and mechanical properties such as chemical or fabrication conditions. In previous research, we introduced a new 3D printing method to fabricate a freestanding overhanging hydrogel structure without supporting structure. This study was measured and analyzed the difference of the mechanical properties of the photocurable hydrogel according to the light intensity using a micro tensile tester. In practically, it was difficult to perform a direct tensile test on a micro (less than 1 mm) size fiber. In this study, the tensile test of the hydrogel fibers could be measured simply and repeatedly using a paper carrier.

마샬 안정도시험기를 이용한 아스팔트 혼합물의 파괴에너지 측정시스템 개발 (Development of Fracture Energy Measurement System of Asphalt Mixture Using Marshall Tester)

  • 김부일;이문섭
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구는 마샬 시험기를 이용하여 아스팔트 혼합물의 균열저항성을 평가할 수 있는 보다 간편하고 합리적인 측정시스템을 개발하는데 목적이 있다. 균열저항성 평가를 위한 파라메타로서 파괴에너지를 이용하였다. 마샬 시험기는 기본적으로 공시체 외부에 거치한 LVDT를 이용하여 수직변형률을 측정하는 시스템이며, 이 같은 외부 수직변형률 측정방식은 하중 스트랩 부분에서 발생하는 국부적인 변형으로 인해 측정오차를 야기할 가능성이 있다. 따라서 추가적인 계측 시스템을 설치하지 않고 기본적인 마샬 시험기를 이용하여 혼합물의 파괴에너지를 측정하기 위해서는 공시체 외부에 거치한 LVDT를 이용한 수직변형률 측정값이 파괴에너지 산정에 적용가능한지 여부를 검증하여야 한다. 이를 위해 본 연구에서는 공시체 중앙부분에서의 수평변형률과 외부에 거치한 LVDT를 이용한 수직변형률을 측정하는 두 가지 방식의 간접인장강도실험을 수행하여 그 차이를 비교 분석하였다. 실험결과, 외부 수직변형률 측정의 문제점으로 지적되었던 하중 스트랩 부분에서 발생하는 국부적인 변형은 파괴시점 이전에는 극히 적은 것으로 나타나 파괴에너지 계산에 오차를 유발하지 않음을 보여주었다. 또한 외부 수직변형률 측정의 실험변동성을 확인한 결과, 변동계수가 15% 이하로 마샬시험기를 이용한 균열저항성 평가시스템에 이용 가능함을 알 수 있었다.

  • PDF

기능성 엘라스토머를 이용한 선형 폴리페닐렌 설파이드의 개질 및 그 특성 (Modification of Linear Polyphenylene Sulfide with Functional Elastomers and Its Properties)

  • 김성기;홍인권;이상묵
    • 폴리머
    • /
    • 제37권3호
    • /
    • pp.399-404
    • /
    • 2013
  • 장기내열성과 파단신율이 우수한 블렌드 수지를 개발하고자 polyphenylene sulfide(PPS)에 7종류의 elastomer를 용융혼합하여 그 가능성을 조사해 보았다. PPS/elastomer(90/10, 80/20, 70/30) 블렌드를 제조한 후 시험편을 압축성형 또는 sheet를 제조하여 capillary rheometer, UTM, impact tester, SEM 등으로 유변학적 거동, 기계적 특성 및 모폴로지를 측정하였고 오븐에서 일주일간 열을 가한 후 다시 기계적 특성을 측정하였다. 열을 가하기 전의 인장강도는 elastomer 종류에 관계없이 비슷하였고 파단신율은 m-EVA의 경우가 가장 큰 값을 보였다. Elastomer 첨가량을 증가시킴에 따라 신율이 증가하였는데 30 wt%정도 첨가 시 박리가 발생하였다. 오븐테스트 이후에는 인장 강도는 더 증가한 반면에 신율은 급격히 감소하였다. 상기의 elastomer들이 PPS와 부분적인 상용성이 있는 것으로 보이는 바 소량의 elastomer 첨가 만으로도 PPS 가공과 관련된 여러 문제 등을 해결할 수 있어 다양한 그레이드의 개발에 적극 활용될 수 있을 것으로 기대된다.