• Title/Summary/Keyword: tendon force

Search Result 210, Processing Time 0.024 seconds

Effect of Forearm Dynamic Taping on Muscle Activity of Extensor Carpi Radialis Brevis During Wrist Isometric and Isotonic Contraction (아래팔 다이나믹 테이핑 적용에 의한 손목 등척성과 등장성 수축 시 짧은 노쪽손목폄근 근활성도의 변화)

  • Huang, Tian-zong;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • Background: Lateral epicondylitis (LE) is the most common chronic musculoskeletal conditions of the upper extremity with pain and wrist extension disability. The tendon which is most affected is the extensor carpi radialis brevis (ECRB). Previous study evaluated the effect of taping technique on patient with LE, but no study investigated the changes of electromyography (EMG) on ECRB when using dynamic taping (DT) technique. Objects: The aim of this study was to investigate the effect of DT technique using dynamic tape on muscle activity of ECRB during wrist isometric extension, isotonic extension and flexion. Methods: Twenty-one healthy subjects volunteered to participate in this study. Subjects were instructed to perform wrist isometric extension, isotonic extension and flexion without and with DT on origin area of ECRB. Wrist isometric extension was performed at 75%, 50% and 25% (%maximal voluntary contraction force), respectively, based on maximum contraction force. Isotonic extension and flexion test used dumbbell. EMG data was collected from ECRB. Results: EMG of ECRB were statistically significant decrease in wrist isotonic extension after DT (p < 0.05). Significant increase in wrist isometric extension during 25% and 50% force task (p < 0.05). Conclusion: This study applied DT technique to suppress the wrist extensor muscles in 21 healthy adults in their twenties. Change in muscle activity was compared in the ECRB muscle during wrist isometric extension, isotonic extension and flexion task. Based on the results of this study, the DT technique applied to the wrist and forearm area can reduce the load on the wrist extensors when the wrist performs various movements during daily life movements or repetitive tasks, and by using these effects, excessive stress is applied to tennis elbow patients.

A Study on the Determination of Reference Parameter for Aircraft Impact Induced Risk Assessment of Nuclear Power Plant (원전의 항공기 충돌 리스크 평가를 위한 대표매개변수 선정 연구)

  • Shin, Sang Shup;Hahm, Daegi;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.437-450
    • /
    • 2014
  • In this study, we developed a methodology to determine the reference parameter for an aircraft impact induced risk assessment of nuclear power plant (NPP) using finite element impact analysis of containment building. The target structure used to develop the method of reference parameter selection is one of the typical Korean PWR type containment buildings. We composed a three-dimensional finite element model of the containment building. The concrete damaged plasticity model was used for the concrete material model. The steels in the tendon, rebar, and liner were modeled using the piecewise-linear stress-strain curves. To evaluate the correlations between structural response and each candidate parameter, we developed Riera's aircraft impact force-time history function with respect to the variation of the loading parameters, i.e., impact velocity and mass of the remaining fuel. For each force-time history, the type of aircraft is assumed to be a Boeing 767 model. The variation ranges of the impact velocity and remaining fuel percentage are 50 to 200m/s, and 30 to 90%, respectively. Four parameters, i.e., kinetic energy, total impulse, maximum impulse, and maximum force are proposed for candidates of the reference parameter. The wellness of the correlation between the reference parameter and structural responses was formulated using the coefficient of determination ($R^2$). From the results, we found that the maximum force showed the highest $R^2$ value in most responses in the materials. The simplicity and intuitiveness of the maximum force parameter are also remarkable compared to the other candidate parameters. Therefore, it can be concluded that the maximum force is the most proper candidate for the reference parameter to assess the aircraft impact induced risk of NPPs.

A Study on the Structural Performance of Post Tensioned Concrete Beam and Slab Subjected to High Temperature (고온을 받은 포스트텐션 콘크리트 보와 슬래브의 구조성능 연구)

  • Choi, Kwang-Ho;Lee, Joong-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.217-223
    • /
    • 2017
  • This research was planned to evaluate the structural performance of post tensioned(PT) concrete member subjected to fire. Prime objective was to suggest some techniques to evaluate the performance of post tensioned concrete beam and slab exposed to high temperature through experiment. To accomplish this objective, the following two scopes have been proceeded to verify the strength reducing ratio of strands and find out the difference of resisting force at the PT concrete members exposed to high temperature through the fire test. The properties of prestressing steel(tendon) in PT concrete beam and slab under variable temperatures were reviewed. The test of this study was shown that stress relaxation occurred at high temperature, and some restoration of tensional force appeared as it got cooling down. The residual tension of the post tensioned beams at 4 hours after reaching the target temperature were 70% at $400^{\circ}C$, 10% at $600^{\circ}C$ and 2% at $800^{\circ}C$. The post tensioned slabs were 94% at $400^{\circ}C$, 84.5% at $600^{\circ}C$ and 62% at $800^{\circ}C$. The reason why the residual tension loss of the post tensioned slab was relatively small was considered to be that the slab was exposed just one side to high temperature and the strength of the strand was restored larger than that of beam. Also, it was confirmed that the post tensioned member inevitably experienced the loss of strength by fire damage, and restoration design of the member should be required to compensate for the value as much as lost strength.

Prestressing Effect of LNG Storage Tank with 2,400 MPa High-Strength Strands (2,400 MPa급 고강도 강연선이 적용된 LNG 저장탱크의 프리스트레싱 효과)

  • Jeon, Se-Jin;Seo, Hae-Keun;Yang, Jun-Mo;Youn, Seok-Goo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.999-1010
    • /
    • 2016
  • High-strength strands have been increasingly applied to recent actual structures in Korea. Structural effect of the increased spacing of sheaths was investigated in this study when the usual 1,860 MPa strands of an LNG storage tank are replaced with 2,400 MPa high-strength strands. First, finite element models of a cylindrical wall of an LNG tank were established and prestressing effect of the circumferential and vertical tendons was considered as equivalent loads. As a result of varying the tendon spacing and prestressing force with the total prestressing effect kept the same, the stress distribution required in design was obtained with the high-strength strands. Also, a full-scale specimen that corresponds to a part of an LNG tank wall was fabricated with 31 high-strength strands with 15.2 mm diameter inserted in each of two sheaths. It was observed that such a high level of prestressing force can be properly transferred to concrete. Moreover, an LNG tank with the world's largest 270,000 kl capacity was modeled and the prestressing effect of high-strength strands was compared with that of normal strands. The watertightness specifications such as residual compressive stress and residual compression zone were also ensured in case of leakage accident. The results of this study can be effectively used when the 2,400 MPa high-strength strands are applied to actual LNG tanks.

Assessment of the Internal Pressure Fragility of the PWR Containment Building Using a Nonlinear Finite Element Analysis (비선형 유한요소 해석을 이용한 PWR 격납건물의 내압 취약도 평가)

  • Hahm, Daegi;Park, Hyung-Kui;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2014
  • In this study, the probabilistic internal pressure fragility analysis was performed by using the non-linear finite element analysis method. The target structure is one of the containment buildings of typical domestic pressurized water reactors(PWRs). The 3-dimensional finite element model of the containment building was developed with considering the large equipment hatches. To consider uncertainties in the material properties and structural capacities, we performed the sensitivity analysis of the ultimate pressure capacity with respect to the variation of four important uncertain parameters. The results of the sensitivity analysis were used to the selection of the probabilistic variables and the determination of their probabilistic parameters. To reflect the present condition of the tendon pre-stressing force, the data of the pre-stressing force acquired from the in-service inspections of tendon forces were used for the determination of the median value. Two failure modes(leak, rupture) were considered and their limit states were defined to assess the internal pressure fragility of target containment building. The internal pressure fragilities for each failure mode were evaluated in terms of median internal pressure capacity, high confidence low probability of failure(HCLPF) capacity, and fragility curves with respect to the confidence levels. The HCLPF capacity was 115.9 psig for leak failure mode, and 125.0 psig for rupture failure mode.

Kinetic Analysis of The foot and ankle during walking (보행시 발과 족관절의 운동학적 분석)

  • Lee, Yun-Seob;Shin, Hyung-Soo
    • PNF and Movement
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • Purpose : This study shows the movements of the ankle and the foot in walking stages, and helps to diagnose and treat the problems of the ankle and the foot. The foot in human is a mean of the transportation, body support, and shock absorber. However, the slightest changes in the anatomical position can cause a significant increase of the stress and force in the ankle and the foot. The regular compressive force in the ankle of the normal person is generated by the contraction of the gastrocnemius and popliteus muscles, and transmitted to the achilles tendon. The plantar flexion about 10 degrees occurs immediately after the heel strike, getting ready for the weight acceptance. The shear force about 80 % of the body weight is generated immediately after the heel off of the mid stance phase. In those who have a problem in the ankle, the compression force at the ankle decreased to 1/3 of the body weight, and the shear force decreased, and the compressive force was reached at their maximum level earlier than the normal people. Conclusion : Analysis of the movements at the ankle and the foot in walking phase can make the effort to diagnose and treat the ankle and foot with the problems. However, the further study is necessary.

  • PDF

A Study of Applied Pressure According to Knee variable During Lachman Test for Anterior Cruciate Ligament using Telos Device (Telos Device를 이용한 전방십자인대 Lachman 검사 시 무릎두께와 활성도에 따른 인가압력에 대한 고찰)

  • Lim, Jong-Cheon;Kim, Sang-Hyuk;Seo, Sang-Hyuk;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.391-398
    • /
    • 2019
  • The purpose of study is to investigate the difference of the daN force applied during the examination using Telos Device and the degree of fluctuation of anterior cruciate ligament according to the individual differences of the muscles involved in knee stability. The examination was done by the Lachman test using Telos Device and the changes of anterior cruciate ligament were measured by varying the force of 0. 15, 30 daN on each right and left side and the force of 30 daN after the bruce protocol. Computed tomography (CT) was used to measure muscle mass. As a result of measuring the degree of fluctuation of the anterior cruciate ligament according to the change of the force applied to the Telos Device, there was a statistically significant difference in the knee fluctuation when 15 daN and 30 daN were applied on both right and left. Also, it is analyzed that the degree of fluctuation of anterior cruciate ligament varies according to the difference of individual's muscle mass. Therefore, it is considered that the force applied to the Telos Device should be changed according to the difference of individual's muscle mass.

A Study on the Reinforcement of Steel Composite Beam Using the External Post-Tensioning Method (외부 후 긴장 공법을 이용한 강합성보의 보강에 관한 연구)

  • Park, Yong-Gul;Park, Young-Hoon;Lee, Seung-Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.549-558
    • /
    • 2000
  • In strengthening structure, the external post-tensioning method which secure clearness in the structure analysis process is adopted to bridges as well as architecture structure. In this study, to investigate the behavior of composite beam in the process of post-tensioning, the amount of prestress force loss, the amount of prestressed compression stress at the lower flange and the behavior of lower flange connected with anchorage are analyzed by comparing the results of finite element analysis with the measured results of installed strain gauges. After finishing the post-tensioning, the strengthening effect of external post-tensioning method is analyzed by static loading test. It is also investigated that the strengthening effect of shear section in the harped external post-tensioning specimens.

  • PDF

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

Effect of Outrigger Wall Reinforced with Post Tension on Reducing Differential Column Shortening (포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과)

  • Lim, You-Jin;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.4
    • /
    • pp.237-244
    • /
    • 2020
  • This study investigates the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening. Since the outrigger wall is a concrete structure, the effect of its long-term behavior should be considered. The long-term behavior of the outrigger wall increases differential column shortening and decreases the shear force acting on the outrigger. When the stiffness of the outrigger becomes small, the effect of its long-term behavior increases. Furthermore, a method of reinforcing with post-tension to reduce differential column shortening is proposed. Following the analysis, it was confirmed that the post-tension method shows a significant reduction in the differential column shortening. This study shows that the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening increases with the prestressing force of tendon.