• Title/Summary/Keyword: temperature-responsive

Search Result 105, Processing Time 0.039 seconds

Temperature and pH-Responsive Release Behavior of PVA/PAAc/PNIPAAm/MWCNTs Nanocomposite Hydrogels

  • Jung, Gowun;Yun, Jumi;Kim, Hyung-Il
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.173-177
    • /
    • 2012
  • A drug delivery system (DDS) was prepared with a temperature and pH-responsive hydrogel. Poly(vinyl alcohol) (PVA)/poly(acrylic acid) (PAAc)/poly(N-isopropylacrylamide) (PNIPAAm)/multi-walled carbon nanotube (MWCNT) nanocomposites were prepared by radical polymerization for the temperature and pH-responsive hydrogels. MWCNTs were employed to improve both the thermal conductivity and mechanical properties of the PVA/PAAc/PNIPAAm/MWCNT nanocomposite hydrogels. Various amounts of MWCNTs (0, 0.5, 1 and 3 wt%) were added to the nanocomposite hydrogels. PVA/PAAc/PNIPAAm/MWCNT nanocomposite hydrogels were characterized with a scanning electron microscope. The mechanical properties were measured with a universal testing machine. Swelling and releasing properties of nanocomposite hydrogels were investigated at various temperatures and pHs. Temperature and pH-responsive release behavior was found to be dependent on the content of MWCNTs in nanocomposite hydrogels.

Responsive fibers from Modification of Acrylic Fibers (아크릴 섬유의 개질에 의한 자극응답성 섬유)

  • 윤기종;우종형
    • Textile Coloration and Finishing
    • /
    • v.16 no.1
    • /
    • pp.53-58
    • /
    • 2004
  • The preparation of responsive fibers from acrylic fibers is studied. Various responsive fibers, such as fibers which change their color on exposure to light or with change in temperature, have been developed and are used commercially However, the responsive material in these fibers are not the fiber itself but chemicals in microcapsules attached to the fibers by finishing, and few fibers exhibit responsive properties by itself. The partial hydrolysis of polyacrylonitrile fibers to obtain pH responsive fibers is presented in this paper. Partial hydrolysis was effected by control of the concentration of the sodium hydroxide used in the hydrolysis, hydrolysis temperature and time. The degree of hydrolysis was evaluated by nitrogen content of the hydrolyzed fibers and their response, change in length, to aqueous solutions of varying pH was studied by continually changing the pH. Significant changes in lengths with pH were observed and the gel transition behavior varied with the conditions of hydrolysis. The hysteresis of the length change was also studied to evaluate the possibilities of using hydrolyzed acrylic fibers as pH sensors.

Preparation of Biodegradable Thermo-responsive Polyaspartamides with N-Isopropylamine Pendent Groups (I)

  • Moon, Jong-Rok;Kim, Ji-Heung
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.12
    • /
    • pp.1981-1984
    • /
    • 2006
  • Novel amphiphilic, thermo-responsive polyaspartamides which showed both LCST (lower critical solution temperature), and sol-gel transition were prepared and characterized. The polyaspartamide derivatives were synthesized from polysuccinimide, the polycondensate of aspartic acid monomer, via successive nucleophilic ring-opening reaction by using dodecylamine and N-isopropylethylenediamine (NIPEDA). At the intermediate composition ranges, the dilute aqueous solution exhibited a thermally responsive phase separation due to the presence of LCST. The phase transition temperature was controllable by changing the content of pendent groups. In addition, a physical gelation, i.e. the sol-gel transition was observed from the concentrated solutions, which was elucidated by dynamic viscoelastic measurements. These novel injectable and thermo-responsive hydrogels have potential for various biomedical applications such as tissue engineering and current drug delivery system.

Origami inspired Temperature Sensor based on Stimuli-Responsive Hydrogel (종이접기 기반 자극 반응성 하이드젤 온도 센서 연구)

  • Na, Jun-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.35-38
    • /
    • 2017
  • A thermally responsive hydrogel has reversibility with temperature during swelling. Here, we proposed origami inspired temperature sensor by using multi-layered hydrogel film. The formation of patterned stripes on microscale film drives bending to an angle that can be controlled linearly. Although temperature range was not wide, measured sensitivity of sensors has high resolution and accuracy. It providing a powerful platform for the design of sensitive sensors and that easily adapt other type of sensors in microscale.

2-Dimensional colloidal micropatterning of cholesteric liquid crystal microcapsules for temperature-responsive color displays

  • Lee, Woo Jin;Kim, Bohyun;Han, Sang Woo;Seo, Minjeong;Choi, Song-Ee;Yang, Hakyeong;Kim, Shin-Hyun;Jeong, Sohee;Kim, Jin Woong
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.393-398
    • /
    • 2018
  • This work offers a promising approach for development of a temperature-responsive colorimetric display platform. For this purpose, uniform thermochromic microcapsules consisting of a cholesteric liquid crystal (CLC) core and a thin polyurethane shell layer were fabricated by conducting in-situ condensation polymerization at the interface of monodisperse CLC-in-water emulsion drops. Colloidal packing-driven microcapsule registry led to exact 2-dimensional positioning of CLC microcapsules into a holes-patterned flexible film stencil. Furthermore, we showed that the designated registry of different color types of CLC microcapsules on the stencil enabled development of a microwriting display technology capable of reversible text representation according to temperature change.

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

Flexible and Transparent Reduced Graphene Oxide Nanocomposite Field-Effect Transistor for Temperature Sensing

  • Tran, QuangTrung;Ramasundaram, Subramanian;Hong, Seok Won;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.387.1-387.1
    • /
    • 2014
  • A new class of temperature-sensing materials is demonstrated along with their integration into transparent and flexible field-effect transistor (FET) temperature sensors with high thermal responsivity, stability, and reproducibility. The novelty of this particular type of temperature sensor is the incorporation of an R-GO/P(VDF-TrFE) nanocomposite channel as a sensing layer that is highly responsive to temperature, and is optically transparent and mechanically flexible. Furthermore, the nanocomposite sensing layer is easily coated onto flexible substrates for the fabrication of transparent and flexible FETs using a simple spin-coating method. The transparent and flexible nanocomposite FETs are capable of detecting an extremely small temperature change as small as $0.1^{\circ}C$ and are highly responsive to human body temperature. Temperature responsivity and optical transmittance of transparent nanocomposite FETs were adjustable and tuneable by changing the thickness and R-GO concentration of the nanocomposite.

  • PDF

An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head (스프링클러헤드 감열부의 열적 특성에 관한 연구)

  • You, Woo-Jun;Moon, Hyo-Jun;Youm, Moon-Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 2012
  • In this study thermal characteristics of heat-responsive element considering conduction, convection and rate of change of element using Response Time Index (RTI) applied to sensitivity test of sprinkler head at home and aborad are theoretically investigated. Analytic solution of temperature distributions with radial direction and time is obtained form energy transport equations, non-homogeneous 2th order partial differential equation, applying to constant wall temperature and symmetric condition in order to analyze thermal characteristics of heat-responsive element for circular cylindrical geometry. Base on the results, the analytic method of this study is fundamental data to practical use for sensitivity test of sprinkler head and design of heat-responsive element.