• 제목/요약/키워드: temperature variation

검색결과 5,676건 처리시간 0.035초

영일만 해역 표면수온의 누년변화 (Secular Variations of Surface Water Temperature in Youngil Bay)

  • 양삼승
    • 수산해양기술연구
    • /
    • 제21권1호
    • /
    • pp.62-66
    • /
    • 1985
  • 영일만 해역에서 표면수온의 주기적 변화와 표면수온과 기온의 관계에서 얻은 결과는 다음과 같다. 영일만 해역(포항과 장기갑)에서 1962년 1월부터 1981년 12월까지 평균표면 수온이 높은 달은 10월과 11월뿐이다. 영일만 해역의 표면수온 주기적 변화는 쓰시마난류의 변화와 밀접한 관계를 갖는 다고 사료된다. 영일만에 장기갑의 누년 평균표면수온은 15$^{\circ}C$이고, 포항항에서는 14.6$^{\circ}C$였다.

  • PDF

CuAlNi 형상기억합금의 결정립 미세화에 따른 시효효과 (The Effect of Ageing on Grain Refinement of CuAlNi Shape Memory Alloy)

  • 양권승;박창선;장우양
    • 열처리공학회지
    • /
    • 제8권1호
    • /
    • pp.65-74
    • /
    • 1995
  • This research was performed to investigate the effect of ageing on grain refinement of 82wt%Cu-13.5wt%Al-4.5wt%Ni-0.1wt% misch metal alloy with ageing temperature and time. The results obtained in this study are as follows; The variation of transformation temperature with ageing temperature had very influence on ageing time at $300^{\circ}C$. But it had not influence on ageing time at $100^{\circ}C$. The variation of transformation temperature after second reversed transformation cycle was not occured in martensitic phase ageing, but $M_s$ point was appeared equally with third reversed transformation cycle in parent phase ageing. The variation of $M_s$ point was not nearly with ageing time at $100^{\circ}C$ ageing temperature. But it was decreasing with ageing time at $300^{\circ}C$ ageing temperature and $A_s$ point was increasing with ageing time. Structure of parent phase ageing was being M18R martensitic and N2H martensitic phase. It was found that ${\alpha}$ and ${\gamma}_2$ phase were created by ageing of long time at $300^{\circ}C$ ageing temperature.

  • PDF

일사영향권내 비균질 토양의 열적거동 예측 모델 (Model to Predict Non-Homogeneous Soil Temperature Variation Influenced by Solar Irradiation)

  • 김용환;현명택;강은철;박용정;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.1-7
    • /
    • 2006
  • This study is to develop a model to predict the soil temperature variation in Korea Institute of Energy Research using its thermal properties, such as thermal conductivity and diffusivity. Soil depth temperature variation is very important in the design of a proper Ground Source Heat Pump (GSHP) system. This is because the size of the borehole depends on the soil temperature distribution, and this can decrease GSHP system cost. If the thermal diffusivity and thermal conductivity are known, the soil temperature can be predicted by either the Krarti equation or the Spitler equation. Then a comparison with the Krarti equation and Spitler equation data with the real measured data can be performed. Also, the thermal properties can be reasonably approximated by performing a fit of the Krarti and Spitler equations with measured temperature data. This was done and, as a result, the Krarti equation and Spitler equation predicted values very close to the measured data. Although there is about a $0.5^{\circ}C$ difference between the deep subsurface prediction (16m - 60m), with this equation, were expected to have model this Non-Homogeneous Soil Temperature phenomenon properly. So, it has been shown that a prediction of non-homogeneous soil temperature variation influenced by solar radiation can be achieved with a model.

푸울 沸騰時 過渡的 流體溫度 變動 (Transient fluid temperature fluctuation in boiling)

  • 김종일;정충식
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.44-47
    • /
    • 1988
  • 본 실험에서는 온도측정용 써미스터인 고감도의 비드형 써미니스터를 이용하여 물의 감압증발에 의한 불등식 푸울내의 깊이 방향과 반경방향의 온도변화를 연속적으로 측정하여 연구한 결과를 보고한다.

특장차량 유압시스템 내 열적 특성 분석 (Experimental Thermal Analysis of Hydraulic System in a Special Vehicle)

  • 최유현;이상호
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.85-91
    • /
    • 2011
  • Experimental analysis has been carried out to investigate thermal characteristics of hydraulic system in special vehicles. Hydraulic system performance is largely influenced by oil temperature, and there are considerable performance decline and malfunctions in the system for high temperature conditions caused by heavy load and continuous operation. Transient oil temperature and pressure variation are analyzed and heat generation rates in the several main system parts are compared for various flow rates. With the start of system operation oil temperature gradually increases, and viscosity deceases by about 70% as temperature increases from $20^{\circ}C$ to $80^{\circ}C$. Operation pressure in the hydraulic system decreases with oil temperature, and its variation rate becomes less steep as oil temperature increases. Heat generation rate in hydraulic pump also depends on the oil temperature, and it reaches maximum near $50^{\circ}C$. These results in this study can be applied to optimal design of efficient hydraulic system in special vehicles.

현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정 (Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale)

  • 박석환
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

온도변화를 고려한 고무엔진마운트의 동특성 변동성 해석 (Variability Analysis of Dynamic Characteristics in Rubber Engine Mounts Considering Temperature Variation)

  • 황인성;안태수;이두호
    • 한국소음진동공학회논문집
    • /
    • 제23권6호
    • /
    • pp.553-562
    • /
    • 2013
  • Vehicle vibrations arise from engine and road surface excitations. The engine mount system of a passenger car sustains the engine weight and insulates the excitation force from the engine system. The dynamic properties of viscoelastic material used for the vehicle engine mounts have large variation due to environmental factors such as environmental temperature and humidity etc. The present study aims to investigate the variability of dynamic characteristics in rubber engine mounts considering both environmental temperature change and material model errors/uncertainty. The engine mounts for a passenger car were modeled using finite element method. Then, the dynamic stiffness variability of the engine mounts were estimated using Monte Carlo simulation method. In order to estimate the variations in the storage and loss moduli of the viscoelastic materials, the material properties of the synthetic rubber were expressed as a fractional-derivative model. Next, in order to simulate the uncertainty propagation of the dynamic stiffness for the engine mounts due to the storage and loss moduli variations, the Monte Carlo simulation was used. The Monte Carlo simulation results showed large variation of the engine-mount stiffness along frequency axis.

온도 변화에 따른 ER 엔진마운트의 제어 특성 (Control Characteristics of ER engine mount considering Temperature Variation)

  • 송현정;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.180-183
    • /
    • 2005
  • The engine mount of vehicle systems is role of support engine mass and isolate noise and vibration from engine disturbance forces. One of attractive candidates to achieve this goai is to utilize a semi-active ER engine mount. By applying this, we can effectively control damping force and hence the noise and vibration by just controlling the intensity of electric field. However, control performance of the engine mount may be very sensitive to temperature variation during engine operation. In this work, we Investigate dynamic performances of ER engine mount with respect to the temperature variation. In order to undertake this, a flow-mode type of ER engine mount is designed and manufactured. Displacement transmissibility is experimentally and numerically evaluated as a function of the electric field. The ER engine mount is then incorporated with full-vehicle model in order to investigate vibration control performance. After formulating the governing equation of motion, a semi-active controller is designed. The controller is implemented through a hardware-in-the-loop simulation (HILS), and control responses such as acceleration level at various engine speeds are evaluated in the frequency and time domains.

  • PDF