• Title/Summary/Keyword: temperature stable

Search Result 3,661, Processing Time 0.038 seconds

A Study on the Fatigue Crack Propagation Threshold Characteristic in Steel of Pressure Vessel at Low Temperature (압력용기용 강의 저온 피로크랙전파 하한계 특성에 관한 연구)

  • 박경동;박상오
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.326-331
    • /
    • 2001
  • In this study. CT specimens were prepared from ASME SA5l6 which was used for pressure vessel plates for room and low temperature service. And we got the following characteristics from fatigue crack growth test carried out in the environment of room and low temperature at $25^{\circ}C$, -3$0^{\circ}C$, -6$0^{\circ}C$, -8$0^{\circ}C$, -10$0^{\circ}C$ and -12$0^{\circ}C$ in the range of stress ratio of 0.1 by means of opening mode displacement. At the constant stress ratio, the threshold stress intensity factor range ΔKsub/th/ in the early stage of fatigue crack growth ( Region I) and stress intensity factor range ΔK in the stable of fatigue crack growth ( Region II) was increased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region. The straight line slope relation of logarithm da.dN -ΔK in RegionII, that is, the fatigue crack growth exponent m increased with descending temperature at the constant stress ratio. It assumed that the fatigue crack growth rate da/dN is rapid in proportion to descend temperature in Region II and the cryogenic-brittleness greatly affect a material with decreasing temperature.

  • PDF

The Development Methods of Fatigue Strength Improvement for the Marine Structural Steel (해양구조용강의 피로강도향상 공법개발)

  • Park, Keyoung-Dong;Jung, Jae-Wook
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.106-111
    • /
    • 2003
  • This study made an experiment On fatigue crack propagation da/dn, stress intensity factor range ${\Delta}K$ respectively in room temperature and in low temperature. And we got the following characteristics from fatigue crack growth test carried Out in the environment of room temperature and law temperature at $25^{\circ}C$, $-60^{\circ}C$, $-80^{\circ}C$, and $-100^{\circ}C$ in the range of stress ratio of 0.3 by means of opening made displacement. The threshold stress intensity factor range ${\Delta}Kth$ in the early stage of fatigue crack growth (Mode I) and stress intensity factor range ${\Delta}K$ in the stable of fatigue crack growth (Made II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at law temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF

Analysis of temperature effects on DC parameters of AlGaAs/GaAs HBT (AlGaAs/GaAs HBT의 DC 파라미터에 미치는 온도영향의 해석)

  • 김득영;박재홍;송정근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.12
    • /
    • pp.39-46
    • /
    • 1996
  • In AlGaAs/GaAs HBT the temperature dependence of DC parameters was investigated over the temperature range between 95K and 580K. The temperature dependence of DC parameters depends on the relative contribution of each of the current components suc as emitter-injection-current, base-injection-current, bulk recombination current, interface recombination curretn, thermal generation ecurrent and avalanche current due to impact ionization within the collector space charge layer in a specific temperature. In this paper we investigated the temperature effects on DC parameters such as V$_{BE,ON}$ current gain, input and output characteristics, V$_{CE, OFF}$, R$_{E}$, R$_{C}$ and analyzed the origins, and extracted the qualitativ econditions for a stable HBTs against the temperature variation. Finally, in order to keep HBTs stable with respect to the variation of temperature, the valance-band-energy-discontinuity at emitter-base heterojunction should be large enough to enhance the effect of carrier suppression at a relatively high temperature. In addition the recombination centers, especially around collector junction, should be removed and the area of emitter and collector junction should be identical as well.

  • PDF

The Effect of the Storage Duration and Temperature of EDTA Specimen for CBC and WBC Differential Count in SE-9000 Automated Cell Counter (SE-9000 자동 혈구계산기에서 EDTA 검체의 보관기간 및 온도가 CBC 및 백혈구 감별계산에 미치는 영향)

  • Hong, Seung-Bok;Kim, Jong-Seok;Shin, Kyeong-Seob
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.147-151
    • /
    • 2006
  • Although various automated CBC analyzers with different WBC analytical principles were consequently introduced to clinical laboratory, the specific information concerning the suitability or unsuitability of aging samples is scarce. For this reason, we studied the effect of storage duration and temperature on CBC parameter in SE-9000 (SYSMEX Medical Electronics Co., Ltd., Kobe, Japan), automated CBC analyzer. We tested 32 K3-EDTA specimens with SE-9000 during 72 hours. Specimens were kept at room temperature (RT) and refrigerated and were analyzed at 0 hr, 4 hr, 8 hr, 24 hr, 48 hr and 72 hr after the collection of the specimens. The percentage changes from initial value for each parameters were calculated. Among the CBC parameters, hemoglobin, red blood cell count, mean corpuscular hemoglobin and platelets were stable for the study period at both temperatures. The mean corpuscular volume (MCV), hematocrit (Hct) and red cell distribution (RDW) increased and the mean corpuscular hemoglobin concentration (MCHC) decreased over time at room temperature. These parameters were stable when refrigerated. The leukocyte count was stable during 72hr at RT and when refrigerated. At room temperature, the relative percentages of neutrophils tend to increase, whereas those of lymphocyte and monocytes tend to decrease after 48 hours. When refrigerated, those of neutrophils and monocytes tend to increase, whereas those of lymphocytes tend to decreased over time. CBC parameters of refrigerated specimen were reliable for 72 hr for the exception of differential count from 24 hr but many CBC parameters, such as MCV, Hct, MCHC, RDW and differential count of leukocyte of blood stored at room temperature for 24 hr were unreliable.

  • PDF

A Study on The Effect of High Temperature on Fatigue Life of The Vehicle Spring Steel (쇼트피이닝 가공된 차량용 스프링강의 피로수명에 미치는 고온의 영향)

  • Park, Keyoung-Dong;Ha, Keyoung-Jun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.167-172
    • /
    • 2002
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, high temperature experiment. And ire got the following characteristics from fatigue crack growth test carried out in the environment of room, and high temperature at $25^{\circ}C,\;100^{\circ}C,\;150^{\circ}C$ and $180^{\circ}C$ in the range of stress ratio of 0.3 by means of opening mode displacement. The threshold stress intensity factor range ${\Delta}Kth$ in the early stage of fatigue crack growth (Region I) and stress intensity (actor range ${\Delta}K$ in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF

Pharmaceutical studies on the polymorphism of hydrochlorothiazide

  • Kim, Bong-Hee;Kim, Johng-Kap
    • Archives of Pharmacal Research
    • /
    • v.7 no.1
    • /
    • pp.47-52
    • /
    • 1984
  • Four polymorphic forms (I, II, III and IV) of hydrochlorothiazide have been characterized on the basis of x-ray diffractometry and differential thermal analysis. Form I was obtained by crystallization from N, N-dimethylformamide and Form II was crystallized from hot methanol. Form III was precipitated from sodium hydroxide aqueous solution by treatment with hydrochloric acid and Form IV was crystallized from 50% methanol. The metastable form I was a most stable form among four polymorphs, which was stable more than ten months at room temperature. The thermodynamic parameters such as heat of solution, enthalpy, entropy, free energy difference and transition temperature were determined by the measurement of intrinsic dissolution rate. The transition temperature and the heat of transition between the metastable Form I an Form II were determined to be $299.15^{\circ}$K and 5.03 Kcal/mole, respectively and free energy difference ($\delta$ F) was 302. 13 cal/mole. Diuretic action of these four polymorphic forms was also evaluated by monitoring the difference in urinary excretion of sodium, potassium and magnesium in rats.

  • PDF

A Study on Acid Treatment of Borosilicate Glass (분상된 붕규산유리의 산처리에 관한 연구)

  • 박용완;신건철
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.2
    • /
    • pp.26-30
    • /
    • 1975
  • The experiment has been carried out to clarify the condition of acid treatment for preventing the crack formation caused by swelling and shrinking during acid leaching process. The borosilicate glass contained phosphorous pentoxide was chosen as the sample, which is recognized to be more homogeneous in phase separation. The various effects, such as kind, cocentration and acid temperature, were investigated. The experimental results are summerized as follows. (1) Sulfuric acid is more stable than hydrochrolic acid for preventing the crack. (2) The optimum concentration of acid lies in the range of 0.1~0.3N. (3) Higher temperature of the acid to treat the separated glass was more stable than lower temperature. (4) The rate of crack decreased with the longer period and the higher temperature of the heat treatment.

  • PDF

Ohmic Resistance of AlGaAs/GaAs HBT at High Temperature (고온 특성을 위한 AlGaAs/GaAs HBT의 설계에 관한 연구)

  • 이준영;신훈법;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.366-370
    • /
    • 2002
  • GaAs has become a very popular material for the fabrication of high frequency, low noise and microwave power devices. GaAs devices are also well suited for high temperature operation because of the large band gap of this material. The standard GaAs technology and device structures have to be modified for stable operation at high temperature. In this paper, AlGaAs/GaAs HBT considering stable ohmic contact at high temperature as well as thermal effect such as self-heating effect are introduced. All the data obtained study will be used as input data for the simulator and the result will be compared with an analytical model available in this study,

  • PDF

Characteristic of the Nocturnal Inversion Layer observed by Tethersonde in Daegu (계류기구로 관측한 대구시 야간 안정층 특성에 관한 사례연구)

  • 김희종;윤일희;권병혁;허만천
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.155-160
    • /
    • 2002
  • Using measured data at Daegu by tethersonde for the period of 1984∼1987, we have investigated the lower atmospheric boundary layer structure including relationships between inversion layer and meteorological factors(wind and temperature), and the inversion strength and inversion height. The inversion layer was defined from the vertical temperature profile and its strength was analyzed with the wind shear as well as the vertical temperature gradient. From October to January, measured inversion layer isn't destroyed, however, in June, after sun rise, it is destroyed by surface heating and mixed layer is developed from surface. According to Pasquill stability classes, the moderately stable cases dominated. It's the larger vertical temperature gradient the lower SBL height. We have introduced B(bulk turbulence scale) which indicated SBL height. It's larger B, the higher SBL height and vice versa. It was noted that the bulk turbulence scale (B) is appropriate to determine the stable boundary layer height.

A Temperature Stable PWM Controller Using Bandgap Reference Voltage (밴드갭 기준전압을 이용한 동작온도에 무관한 PWM 컨트롤러)

  • Choi, Jin-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1552-1557
    • /
    • 2007
  • In this work, temperature stable pulse width modulation controller using bandgap reference voltage is proposed. Two bandgap reference voltages are designed by using BiCMOS technology which are temperature dependent and independent voltage references. PWM controller is designed by using 3.3 volt supply voltage and the output frequency is 1MHz. From simulation results, the variation of output pulse width is less than form +0.86% to -0.38% in the temperature range $0^{\circ}C\;to\;70^{\circ}C$.